Latest products and information available at www.sealite.com
18
SL-15 with User-Adjustable Flash Settings
1–2NM+ Solar Marine Light
Configuration Settings
The intensity and flash codes can be changed using the switches on the lamp circuit board or with the
IR Remote Control. The lamp intensity and flash code settings are set to the last detected change,
carried out with the IR Remote Control or by changing the switch positions.
Example #1:
If the intensity is set at 100% with the intensity switches, and is then set to 50% using
the IR Remote Control, the intensity setting will change to 50%. If the intensity is then set to 75% using
the switches, the new intensity value will be 75%.
In order to change intensity settings using the IR Remoter Control, the lamp must be powered.
The lamp can detect a change in switch settings if they are changed while the light is powered down.
1
T/C
T/C
L
B
3
T/C
T/C
L
B
Storage Mode (Advanced users)
For situations where the lantern is put into storage but with access to daylight, the IR Remote control
can be used to configure the lantern into Storage Mode.
This mode manually forces the lantern to turn off, but with access to daylight it will still charge battery
pack. However the lantern will not keep track of the date.
In Storage Mode, the GPS is disabled however the lantern will still respond to IR commands.
The lantern will automatically enter Storage Mode, if it is hibernating and it has not detected any light
for 20 hours.
Enter Storage Mode
By pressing the following key sequence the lantern will enter Storage Mode:
The lantern will leave storage mode when exposed to daylight or if the power switch is turned OFF and
ON again.