INSTRUCTIONS FOR:  

INFRARED LASER DIGITAL THERMOMETER

MODEL:

VS904

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 
and properly maintained, give you years of trouble free performance.

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE 
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.

SAFETY INSTRUCTIONS

1.1

GENERAL SAFETY.

!

WARNING!

Ensure that Health & Safety, local authority and general workshop practice regulations are adhered to when using this 

equipment.

!

WARNING!

DO NOT aim the laser beams at your or another person’s or animal’s eye and beware of reflections from mirrors or other 

shiny surfaces.

"

Familiarise yourself with the applications, limitations, and potential hazards of the thermometer.

"

Keep the thermometer clean and in good condition.

"

Protect the thermometer from the following:

Electro-magnetic fields from engine components closer than 125mm. 

Static electricity.

Thermal shock caused by large and/or rapid ambient temperature change.

High temperatures.

#

DO NOT

get the thermometer wet or use in damp or wet locations or areas where there is condensation.

#

DO NOT

use the thermometer for any purpose other than that for which it is designed.

#

DO NOT

allow untrained persons (particularly children) to operate the thermometer.

#

DO NOT

operate the thermometer when you are tired or under the influence of alcohol, drugs or intoxicating medication.

!

WARNING!

The warnings, cautions and instructions discussed in this instruction manual cannot cover all possible conditions and 

situations that may occur. It must be understood that common sense and caution are factors which cannot be built into this product,
but must be applied by the operator. 

2.

INTRODUCTION & SPECIFICATION

Fast and simple way to tackle diagnosis of engine and vehicle faults. VS904 detects energy emission in the infrared spectrum and 

converts reading into a display of temperature. Features laser pointer to indicate area being sampled. Temperature is displayed on a

large LCD panel. Temperature can be shown in either °C or °F. Powered by 2 x AAA batteries (not included). 
2.1

Specification

Range:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-35 to +365ºC (-3

1

 to +689ºF).

Resolution(-9.9~199.9°C): . . . . . . . . . . . . . . . . .0.2ºC/0.5ºF. 
Response Time (90%):  . . . . . . . . . . . . . . . . . . .1 second.
Operating Range:  . . . . . . . . . . . . . . . . . . . . . . .0~50°C (32~122°F).
Accuracy, (Tobj* = 15 - 35°C, Tamb* = 25°C):  . .±1.5°C (

2.7

°F).

Accuracy, (Tamb = 23 ± 3°C):   . . . . . . . . . . . . .Tobj=0~365°C: ± 2.5% of reading or 2.5ºC (4.5°F) which ever is greater.

Tobj=

 -

35~0°C: ± (2.5°C + 0.05°C).

Distance to Spot Diametr Ratio :  . . . . . . . . . . . .8:1.
Emissivity:  . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.95 fixed.
Laser  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Class II.
Battery Life:  . . . . . . . . . . . . . . . . . . . . . . . . . . .typically 14hours continuous use.
Battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 x AAA.
Dimensions:  . . . . . . . . . . . . . . . . . . . . . . . . . . .166.4 x 339 x 63mm.  
Weight:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 grams (including batteries). 
Auto Shutdown:  . . . . . . . . . . . . . . . . . . . . . . . .15 sec when idle.

Tobj* object temperature. Tamb* ambient temperature.

1.2

LASER SAFETY.

The VS904 utilises a Class II laser that emits low levels of visible radiation (i.e. wavelengths between 400 and 
700 nanometres) which are safe for the skin but not inherently safe for the eyes. The Class II emission limit is 
set at the maximum level for which eye protection is normally afforded by natural aversion responses to bright
light. Accidental eye exposure is therefore normally safe, although the natural aversion response can be 
overridden by deliberately staring into the beam, and can also be influenced by the use of alcohol or drugs.

!

WARNING!

Do not look or stare into the laser beam as permanent eye damage could result. 

$

DO NOT

direct the laser beam at any person’s (or animal’s) eyes as eye damage could result.

#

DO NOT

operate the thermometer when you are tired or under the influence of alcohol, drugs or intoxicating medication.

"

Be aware that reflections of the laser beam from mirrors or other shiny surfaces can be as hazardous as direct eye exposure. 

VS904 - 1 - 260607

01284 757500

01284 703534

[email protected]

Sole UK Distributor

Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk

Web

email

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component

parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION: 

For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and

address, including postcode.

Reviews: