background image

2-YEAR WARRANTY

www.XCICONTROLS.com

INSTRUCTION MANUAL

XCI

TSZ-1

2 Heating and 1 Cooling with Dual Fuel Capability

0706-XCI Manual-TSZ-1:TSZ-1  6/20/07  3:53 PM  Page 1

Summary of Contents for TSZ-1

Page 1: ...2 YEAR WARRANTY www XCICONTROLS com INSTRUCTION MANUAL XCI TSZ 1 2 Heating and 1 Cooling with Dual Fuel Capability ...

Page 2: ...t No TOS Outdoor Wireless Temperature Transmitter and Receiver Kit Includes Transmitter Antenna Receiver Module 2 AA Batteries Accurately Displays Current Outdoor Temperature on the XCI TSZ 1 Thermostat and Enables Dual Fuel Capability 0706 XCI Manual TSZ 1 TSZ 1 6 20 07 3 53 PM Page 2 ...

Page 3: ...PUMP 34 ADVANCED SETTINGS CALIBRATION 36 SIMPLE THERMOSTAT MODE 38 TROUBLESHOOTING 39 WARRANTY 40 XCI TSZ 1 Introducing the XCI TSZ 1 touch screen thermostat with 2 stage heating 1 stage cooling control and fossil fuel switch available only when combined with XCI Outdoor Wireless Transmitter and Receiver Kit 7 Day programmable with 4 events per day including fan Large easy to read dot matrix displ...

Page 4: ... THERMOSTAT A thermostat with the capability of automatically adjusting temperature set point to pre selected settings at pre selected times SETBACK The automatic alteration of the thermostat control point s by means other than manually changing the temperature set point SET POINT The desired temperature setting on an electromechanical or electronic thermostat Install your XCI thermostat approxima...

Page 5: ...ostat by grasping the unit firmly at the bottom lip and pulling gently until the two piece are apart 3 Align the backplate to the wall 4 Mark the three locations for drilling the 3 16 holes required for the plastic screw anchors 5 Remove the backplate and drill the three 3 16 holes in these locations 6 Insert the plastic gyproc screws and ensure that they are snug in the wall 7 Securely mount the ...

Page 6: ... COOL COMMON RC DH H C Y2 RH W2 OB W1 EH G Y1 HEAT 24V FAN COMMON ONE STAGE COOL AND ONE STAGE HEAT RC DH H C Y2 RH W2 OB W1 EH G Y1 COOL HEAT 2 HEAT 1 24V FAN COMMON ONE STAGE COOL AND TWO STAGE HEAT RC DH H C Y2 RH W2 OB W1 EH G Y1 COOL 0706 XCI Manual TSZ 1 TSZ 1 6 20 07 3 53 PM Page 10 ...

Page 7: ...W2 OB W1 EH G Y1 HEAT REVVALVE 24V FAN COMPRESSOR COMMON ONE STAGE HEAT PUMP WITH AUX EMERGENCY HEAT RC DH H C Y2 RH W2 OB W1 EH G Y1 HEAT TRANSFORMER ONE TRANSFORMER RC DH H C Y2 RH W2 OB W1 EH G Y1 HEAT TRANSFORMER COOL TRANSFORMER CUT TWO TRANSFORMERS RC DH H C Y2 RH W2 OB W1 EH G Y1 0706 XCI Manual TSZ 1 TSZ 1 6 20 07 3 54 PM Page 12 ...

Page 8: ...tat features and settings Displays Installer Message to review important information CONTROL SCREEN 15 INSTRUCTION MANUAL ToaccesstheCONTROLSCREEN simplytouchtheHOMESCREENScreen anywhere From the CONTROL SCREEN you can Current Room Temperature Current Outdoor Temperature Current Thermostat Operation Mode Current Temperature Control Mode Current Fan Operation Mode Fan Operation Indicator Vacation M...

Page 9: ...ulate room temperature OFF Will not control temperature Climatouch will continue to display the current room temperature current room humidity and outdoor temperature THERMOSTAT OPERATION MODES 16 XCI TSZ 1 The thermostat can operate in PROGRAM MODE or can HOLD a fixed temperature RUN PROGRAM Initiates the 7 day Programmable Temperature Control Program with 4 independent events per day To set up a...

Page 10: ...and for heating or cooling FAN ON The fan runs continuously FAN INTERMITTENT The fan runs 10 minutes per 1 2 hour providing a convenient way to improve air quality and save energy When the fan is running the animated fan icon will appear on the HOME SCREEN 18 XCI TSZ 1 FAN OPERATION MODES 0706 XCI Manual TSZ 1 TSZ 1 6 20 07 3 54 PM Page 18 ...

Page 11: ...m and should be performed only by a qualified installer 21 INSTRUCTION MANUAL MENU SCREEN 20 XCI TSZ 1 To access the MENU SCREEN simply touch MENU from the CONTROL SCREEN From the MENU page you can Access DATE AND TIME SETTINGS to enter the accurate date and time Access PROGRAM SETTINGS to pre program temperature changes during each day of the week Access ENERGY WATCH to display kWh consumption an...

Page 12: ...y fan operation mode button Enter the event START TIME with Hour Minute and AM PM buttons Choose desired TEMPERATURE SET POINT with and buttons Select the next event and repeat the steps described above Once finished select the next day of the week that you would like to program The thermostat will prompt you to copy the settings Repeat steps to program other days of the week 22 XCI TSZ 1 DATE AND...

Page 13: ...t 6 00AM OFF screen background is determined by REVERSE function CONTRAST Toggle the screen contrast settings button 1 10 to select the screen con trast that suits best your thermostat surroundings XCI recommends the setting of 7 24 XCI TSZ 1 ENERGY WATCH ENERGY WATCH feature provides a report on the energy con sumption and the dollar cost of operating your HVAC system for up to the last 255 days ...

Page 14: ...ANT HEAT or COOL must be selected from the CONTROL SCREEN before entering the Vacation Settings screen To begin select Vacation Mode ON Select the START Date Select the END Date Adjust the HEAT or COOL temperature setpoint the Vacation mode begins at 10 PM on the day of your departure and ends at Midnight on the day of your arrival When the Vacation mode is active the suitcase icon appears on the ...

Page 15: ...ight Time ON or OFF dependent on your Time Zone FILTER Enter the air filter fan run time information here The Filter Monitor fea ture uses this information to inform you when to change your air filter by display ing CHANGE FILTER icon on the HOME SCREEN ENERGY WATCH Enter the HVAC system consumption parameters rounded off to kW as well as your electrical energy cost kW and the ENERGY WATCH feature...

Page 16: ... over HP Cut ON or OFF Cut Temperature Temperature in Celsius 5 c to 25 c Temperature in Fahrenheit 13 F to 41 F 1 Available only in combination with WIRELESS OUTDOOR TEMPERATURE TRANSMITTER AND RECEIVER KIT TOS ADVANCED SETTINGS SYSTEM CONFIGURATION 30 XCI TSZ 1 IMPORTANT By inadvertently modifying system configuration settings you may seriously degrade HVAC system performance Choose system heati...

Page 17: ...D SETTINGS DIFFERENTIAL SETTINGS 32 XCI TSZ 1 The XCI TSZ 1 allows you to control up to 2 Stages of Heating and 1 Stages of Cooling dependent on the type of system you have configured 1ST STAGE DIFFERENTIAL Set temperature difference between temperature set point and actual temperature reading before 1st stage heating or cooling is initiated 2ND STAGE DIFFERENTIAL Set temperature difference betwee...

Page 18: ...MP HP ON when Furnace On Heat Pump and Furnace can operate together when 2nd stage furnace is required HP OFF when Furnace On turns off the Heat Pump when the furnace is On required on some gas or oil furnaces 0706 XCI Manual TSZ 1 TSZ 1 6 20 07 3 54 PM Page 34 ...

Page 19: ... F 2 5 C 2 0 4 F 2 0 C 1 5 3 F 1 5 C 1 0 2 F 1 0 C 0 5 1 F 5 C ADVANCED SETTINGS CALIBRATION 36 XCI TSZ 1 Calibration of Temperature Your XCI Thermostat is rated for an accuracy of 1 F 1 C If you have determined due to drafts sunlight or other environmental factors that your thermostat requires calibration follow this easy guide Common cause of offset are lack of air circulation drafts or skylight...

Page 20: ...touch to reset password appears touch the screen your PIN will be erased and the thermostat will unlock SIMPLE THERMOSTAT MODE 38 XCI TSZ 1 Your thermostat can also function as a virtual non programmable thermostat after it has been switched to a SIMPLE MODE To enable SIMPLE MODE press the reset button take off the thermostat face plate and press the reset button located in the bottom right hand c...

Page 21: ... original warranty whichever is longer OBTAINING WARRANTY SERVICE Customer must contact and return product to a local XCI Controls L P product dealer or installer within the applicable warranty period to obtain warranty service Dated proof of original purchase will be required XCI Controls L P will not be responsible for Customer s memory data contained in stored on or integrated with any products...

Page 22: ...0706 XCI Manual TSZ 1 TSZ 1 6 20 07 3 54 PM Page 42 ...

Page 23: ...NCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION TECHNICAL SUPPORT 1 866 XCI CTRL 1 866 924 2875 PHYSICAL DIMENSIONS Case 5 75 x 4 75 x 1 25 145mm x 120mm x 30mm Screen 4 1875 106mm ELECTRICAL RATING 24 volt AC DC Class 2 maximum 4 amps Temperature Accuracy 1 F 0 5 C TSZ 1 MANUAL PRINTED IN CHINA www XCICONTROLS com PATENTS 7 185 825 7 156 318 7 145 110 7 050 026 7 028 912 6 902 117 6 786 ...