background image

dIESEL & FLUId FLOW METER

MODEL NO: 

TP956.V2

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

 

 

‰

  

WARNING! 

Ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this  

 equipment.

 

9

   Familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to this product.

 

9

   Maintain the meter in good condition (use an authorised service agent).

 

9

   Replace or repair damaged parts. Use genuine parts only. Non authorised parts will invalidate the warranty.

 

9

   Use only to meter diesel fuel and oils. 

 

9

   Ensure safety eye protection and protective clothing are worn when using this product.

 

9

   Keep the work area clean, uncluttered and ensure there is adequate lighting.

 

9

   Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.

 

9

   Keep children and unauthorised persons away from the working area.

 

9

   After use, drain any fluids from the equipment before storage. 

 

9

   Dispose of waste liquids in accordance with local authority regulations.

 

8

  

dO NOT 

exceed the maximum pressure of 145psi (10bar).

 

8

  

dO NOT

 use the equipment near open flames.

 

8

  

dO NOT 

smoke whilst using this equipment. 

 

8

  

dO NOT

 use for corrosive fluids.

 

8

  

dO NOT 

dismantle, tamper with or adapt the equipment for any purpose other than for which it is designed.

 

8

  

dO NOT 

use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.

 

8

  

dO NOT 

use taper connections, use parallel connectors only.

 

8

 

  dO NOT 

use compressed air on the turbine, the excessive rotation will damage the unit.

 

9

   Keep the meter clean and store in a safe dry, childproof location. 

 

‰

   

WARNING! dO NOT

 allow uncontrolled discharge of fluids thus polluting the environment. All liquids must be disposed of according to 

 

local authority regulations.

 

‰

  

WARNING!

 The correct working of the nutating disk may be affected if solid particles enter the measuring chamber. Always filter the  

  fluid by installing a filter on the meter inlet.

2.  INTROdUcTION

 

Volumetric nutating disc meter with three digit resettable batch display and six digit cumulative total display. Unique filter and flange  

 

assembly allows meter to be positioned in four configurations. Suitable replacement meter for Model no. TP955 Diesel/Fluid  

 

 

Transfer System.

3.  SPEcIFIcATION

Model No. ...............................................................

TP956.V2

Flow Rate ..........................................................

20-120ltr/min

Weight ........................................................................... 1.8kg

M

ax. Working Pressure

 ................................... 145psi (10bar)

4.  INSTALLATION

 

NOTE: 

Numbers refer to Parts Diagram section 9.

4.1. 

  

The meter can be installed in any position, on rigid pipelines or flexible 

 

hoses, directly on pumps or tanks. The meter flow direction is fixed and 

 

indicated by an arrow on the outlet.

4.2. 

  

Meter cover (3) can be removed and the Register base (8), along with 

 

Meter Unit (6), can be rotated at every 90° orientation in four different 

 positions.

 

NOTE:

 The rear of the meter body is equipped with 4 blind holes which 

 

can be threaded (M5) for a mounting.

4.3.    

HOW TO ROTATE THE dISPLAY

4.3.1. 

  

Remove the four retaining screws (5) and lift up the meter cover (3), fig.1.

4.3.2.   

Loosen the 2 screws, see fig.2, on both sides and separate the meter unit (6) from the register base (8).

Refer to 

instruction

manual

Wear eye 

protection

Wear protective 

clothing

T

P956.V2 | Issue:1  15/10/18

Original Language Version

© Jack Sealey Limited

fig.1

Summary of Contents for TP956.V2

Page 1: ...equipment for any purpose other than for which it is designed 8 8 DO NOT use the unit if it has been dropped or mishandled check the unit to ensure there is no damage 8 8 DO NOT use taper connections use parallel connectors only 8 8 DO NOT use compressed air on the turbine the excessive rotation will damage the unit 9 9 Keep the meter clean and store in a safe dry childproof location WARNING DO NO...

Page 2: ...op the full flow repeatedly until the required level is maintained 5 2 6 The Meter Value should be matched with the Container Value as given below If the Meter Value is higher than Container Value loosen the calibration screw 16 If the Meter Value is lower than the Container Value tighten the calibration screw 16 5 2 7 Repeat steps until accuracy is satisfactory 5 2 8 Tighten the plug with seal 17...

Page 3: ...eat fig 5 7 2 3 To check the inside of the measuring chamber 13 remove the O ring fig 5 7 2 4 Divide the two half chambers 10 and 12 containing the nutating disk 11 fig 6 7 2 5 Use a soft brush or a small tool i e a screwdriver to clean the measuring chamber Be careful not to damage the chamber or the disk fig 7 7 2 6 To reassemble reverse the described procedure paying particular attention to lub...

Page 4: ...lations Note It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice Important No Liability is accepted for incorrect use of this product Warranty Guarantee is 12 months from purchase date proof of which is required for any claim Parts support is available for this product Please email sales sealey co u...

Reviews: