3.  SPECIFICATION  

4. CONTROLS

Model No:

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TM104

AC Voltage (Accuracy):  . . . . . . . . . . . . . . . . . . . . . . . 4V, 400V (±0.8%), 600V (±1.5%)

DC Voltage (Accuracy):  . . . . . . . . . . . . . . . . . . 0-400mV, 400V (±0.7%), 600V (±1.0%)

AC Current (Accuracy):  . . . . . . . . . . . . . . . . . . . .40mA, 400mA (±1.5%), 10A  (±3.0%)

DC Current (Accuracy):  . . . . . . . . . . . . . . . . . . . .40mA, 400mA (±1.2%), 10A  (±2.0%)

Resistance (Accuracy):. . . . . . . . . . . . . . . . . . . . .

400Ω, 4MΩ (±1.2%), 40MΩ (±2.0%)

Capacitance (Accuracy):  . . . . . . . . . . . . . . . . . . . . . . . 4nF, 40µF (±3%), 200µF (±8%)

Temperature (Accuracy):  . . . . .-20°C-0°C (±5%), 0°C-20°C (±3%), 20°C-400°C (±2%)

Frequency (Accuracy): . . . . . . . . . . . . . .9.999Hz (±2.0%), 99.99Hz, 9.999kHz(±1.5%),  

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  99.99kHz, 199.99kHz  (±2.0%)

Duty Cycle: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.1%-99.9% (±3.0%)

Continuity Audible:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes

Diode Test:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes

Digits x Height: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 x 19mm

Low Battery Indicator:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes

Batteries (Supplied):. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 x 9V

Information:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Data-Hold & Auto Power Off

Size (L x W x D):. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 x 85 x 40mm

Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320g

Conformity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC 1010, CATIII 600V

Humidity:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30-90% (±8%)

Sound Level:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-100dB  (±5dB at 94dB)

Light:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-40,000Lux (±5%) (x10)

 

4.1.  Button Functions

4.1.1. 

Rotary Selector

 (fig.1.1). Switches the meter on or off and selects the various functions.

4.1.2. 

HOLD

 Button (fig.1.2.). Pressing the hold button at any point will hold the instant display until the button is pressed again to release it.

4.1.3. 

FUNCTION

 Button. (fig.1.3). When measuring current and voltage, the function button will change between DC and AC.

 

When measuring resistance, capacitance, diode and continuity; the function button can be used to cycle between settings.

4.1.4. 

RANGE

 Button. (fig.1.4). The default setting for measuring current, voltage and resistance is auto-ranging. If it is desired to select    

 

manual ranging, press the RANGE button. Each subsequent press will advance the measurement range. Pressing range for 

 

2 seconds will revert to auto-range.

 

Note: 

When 'OL' is displayed, the reading is above the range selected manually.

4.1.5. 

Hz/DUTY

 Button (fig.1.5). By pressing the 'Hz/DUTY' button whilst in the frequency setting, the duty cycle function will be selected.

 

When measuring voltage or current, one press of the HZ/DUTY button will display the frequency and a second press the duty cycle of  

 

the circuit being tested.

4.1.6. 

REL

 Button (fig.1.6).  The Relative button allows comparison between circuits. Pressing the button will zero the display: a subsequent  

 

reading will show the difference between the two readings.

4.1.7. 

LIGHT

 Button (fig.1.7). Switches on the backlight. Owing to the power demands of the backlight, it will fade and extinguish after 

 

5 seconds. Frequent use of the backlight will shorten the life of the battery significantly.

4.2. Battery

4.2.1.

 

Low battery voltage is indicated by the appearance of the      icon on the left of the display screen.

 

When the battery icon is showing, readings may become unreliable; the battery should, therefore, 

 

be changed as soon as possible. 

 

WARNING!

 Remove the test leads before opening battery compartment.

4.2.2.

 

To insert, replace or remove the battery; remove the two screws and open the battery compartment 

 

as in fig.2.

4.2.3.  Replace the battery, then refit and secure the cover

4.3. 

Auto Power Off

4.3.1.  If the meter has been left with power on for 15 minutes, it will give an audible warning and then switch

 off.

4.3.2.  To restore power from this condition; switch the rotary selector to off and then back on again or press 

 FUNC, RANGE, Hz/DUTY or REL switch.

4.3.3.  To disable the auto power off facility, press FUNC whilst the power is on.

fig.2

5. OPERATION

 

WARNING!

 Ensure that the safety and operational instructions are read, understood and applied before connecting the multimeter.    

 

Only when the procedures are understood is it safe to proceed with testing.   

 

5.1.   MEASURING VOLTAGE (AC and DC)

5.1.1.  Connect the black test lead to the COM input socket (fig.1.10)and the red test lead to the V input socket (fig.1.11)

5.1.2.

 

Set the rotary switch to V   . The meter default setting is auto-ranging (denoted by AUTO in the display). To deselect auto-ranging,    

 

see section 4.1.4.

5 .1.3.  Connect the test probes across the source or load being measured. 

5.1.4.  Turn on the power, the voltage will be displayed and the polarity of the red test lead connection will be indicated when measuring DC   

 voltages. 

5.1.5.  Press FUNC to scroll between AC and DC measurements.

5.1.6.  The measured value will be displayed.

5.1.7.  If measuring an unknown voltage with the manual range setting, select the highest voltage scale first and work down to the voltage    

 measured.

Original Language Version

 © Jack Sealey Limited

TM104      Issue No: 1 10/06/15

FIG.1

Summary of Contents for TM104

Page 1: ...en making resistance or diode tests ONLY operate the multimeter when the back cover is in place and fastened securely If any abnormal readings are observed the multimeter must be checked out by an authorised technician ALWAYS turn off the multimeter and disconnect the test leads before opening the back cover to replace the battery When not in use store the multimeter carefully in a safe dry childp...

Page 2: ...ro the display a subsequent reading will show the difference between the two readings 4 1 7 LIGHT Button fig 1 7 Switches on the backlight Owing to the power demands of the backlight it will fade and extinguish after 5 seconds Frequent use of the backlight will shorten the life of the battery significantly 4 2 Battery 4 2 1 Low battery voltage is indicated by the appearance of the icon on the left...

Page 3: ...5 6 1 Connect the black lead to the COM input socket fig 1 10 and the red lead to the Ω input socket fig1 11 5 6 2 Set the rotary switch to the position and connect the test leads across the two points of the circuit under test 5 6 3 If continuity exists i e resistance is less than about 40Ω the built in buzzer will sound 5 7 FREQUENCY MEASUREMENT 5 7 1 Connect the black lead with the COM input so...

Page 4: ...ils see section 4 2 Under the Waste Batteries and Accumulators Regulations 2009 Jack Sealey Ltd are required to inform potential purchasers of products containing batteries as defined within these regulations that they are registered with Valpak s registered compliance scheme Jack Sealey Ltd s Batteries Producer Registration Number BPRN is BPRN00705 Environmental Protection Recycle unwanted materi...

Reviews: