4.

OPERATION

4.1.

MEASURE VOLTAGE

4.1.1.

Set the function switch in V    /A~ position, press “SELECT” button to select Vdc or Vac measuring mode.

4.1.2.

Connect the test lead and test probe across the source or circuit to be measured.

4.1.3.  Read the reading. 

NOTE!

The max. permitted voltage is 600Vac/dc rms.
The meter may show an unsteady reading when the test lead and test probe are not in contact with the circuit to be 
measured, this is normal because the meter’s sensitivity is very high. When the test lead and test probe touch the circuit to be
measured, the display will show the true reading.

4.2.

MEASURING RESISTANCE

4.2.1.  Set the function switch in the “ 

“ position.

4.2.2. Connect the test lead and test probe across the circuit to be measured.
4.2.3.  Read the reading.

NOTE!

When the measured resistance is more than 1M

, it will take several seconds for the reading to be steady.

When the test lead and test probe are open, the display will show “OL” for overload indication.
Before you measure in-circuit resistance, ensure that the power supply has been switch off and all the capacitors have 
been fully discharged.

4.3

TESTING DIODE

4.3.1.  Set the function switch in “      ” position.
4.3.2.

Press the “SELECT” button to set the meter in diode range.

4.3.3.

Connect the test probe to the anode of the diode and the black test lead to the cathode of the diode.

4.3.4.  Read the reading.

NOTE!

The display will show the approximate value of the forward-voltage drop of the diode. If you connect the test probe and 
test lead across the diode in the wrong direction, the display will show "OL".

4.4.

TESTING FOR CONTINUITY

4.4.1.  Set the function switch in "    " position.
4.4.2.  Press the "SELECT" button to set the meter in "    " range.
4.4.3.  Connect the test probe and test lead across the circuit to be measured.
4.4.4.  If < about 50

, the buzzer will sound.

4.4.5.  Read the reading.

4.5.

MEASURING CAPACITANCE

4.5.1.  Set the function switch in "      " position.
4.5.2.  Press the "SELECT" button to set the meter in capacitance range.
4.5.3.  Connect the test probe and test lead across the capacitor to be measured.
4.5.4.  Read the reading.

NOTE!

When you measure a high-voltage capacitor, it will take several seconds for reading to steady (30 seconds for 
100mF range).

4.6.

MEASURING DUTY CYCLE

4.6.1.  Set the function switch in "DUTY" position.
4.6.2.  Press the "SELECT" button to set the meter in duty cycle range.
4.6.3.  Connect the test probe and test lead across the source or load to be measured.
4.6.4.  Read the reading.

4.7.

MEASURING FREQUENCY

4.7.1.  Set the function switch in "Hz" position.
4.7.2.  Press the "SELECT" button to set the meter in Hz range.
4.7.3.  Connect the test probe and test lead to the signal to be measured.
4.7.4.  Read the reading.

4.8.

AUTO POWER-OFF

4.8.1.

When idle, the meter will automatically power off and give 5 short beeps and one long beep. If you move the function switch 
or press  “HOLD” or “SELECT”, the meter will turn on.

TA300 - 1 - 310807

Summary of Contents for TA300

Page 1: ...ow voltage supply Examples are measurements on domestic appliances portable tools etc DO NOT use the meter to measure within Measurement Categories lll and lV DO NOT use the meter around explosive gas vapour or dust Remove the test lead and probe from a circuit before opening the battery compartment DO NOT operate the meter with the battery cover removed When not in use store the meter carefully i...

Page 2: ...Accuracy 400mV 0 1mV 4V 1mV 0 8 4 40V 10mV 400V 100mV 600V 1V 1 4 RESISTANCE Range Resolution Accuracy 400Ω 0 1Ω 1 2 2 4kΩ 1Ω 40kΩ 10Ω 1 2 400kΩ 100Ω 4MΩ 1kΩ 1 2 2 40MΩ 10kΩ 1 5 2 CAPACITANCE Range Resolution Accuracy 4nF 1pF 25 5 40nF 10pF 400nF 100pF 4µF 1nF 10 5 40µF 1nF 100µF 100nF DUTY CYCLE Range Resolution Accuracy 0 1 99 0 01 2 5 4 DIODE Range Resolution Open circuit Voltage 1mV About 1 5V...

Page 3: ... 3 4 Read the reading NOTE The display will show the approximate value of the forward voltage drop of the diode If you connect the test probe and test lead across the diode in the wrong direction the display will show OL 4 4 TESTING FOR CONTINUITY 4 4 1 Set the function switch in position 4 4 2 Press the SELECT button to set the meter in range 4 4 3 Connect the test probe and test lead across the ...

Page 4: ...replace the cover and reinstall the screw NOTE Pay attention to the polarity of the new batteries do not reverse them otherwise the unit will be damaged Only use the specified batteries 2 x 1 5V AAA WARNING DO NOT attempt to repair or service your meter unless you are qualified to do so and have the relevant calibration performance test and service information To avoid electrical shock or damage t...

Reviews: