8
Do not
leave the cleaning tank operating unattended.
8
Do not
operate the cleaning tank when you are tired, under the influence of alcohol, drugs or intoxicating medication.
9
The tank is not suitable for paint thinners, gun wash or air drying.
9
When not in use switch the cleaning tank off, remove plug from the power supply.
9
dispose of waste liquids in accordance with local authority regulations.
Warning! Do not
allow uncontrolled discharge of fluids thus polluting the environment.
2. introDuction
One-piece tank with triple baked finish and fully sealed magnetic drive pump unit with replaceable impeller. Smaller capacity tank
is suitable for benchtop mounting. Recirculated fluid is filtered before entering the pump and is directed over the workpiece with a
flexible metal delivery nozzle. Removable shelf included.
3. specification
model no ......................................................... Sm21.V4
overall Height .................................................... 225mm
Tank Height ....................................................... 210mm
Tank depth ......................................................... 290mm
Tank Width ............................................................... 395
Pump output/hr ....................................................... 90ltr
motor Power ............................................................26W
Supply ....................................................................230V
Weight .................................................................6.88Kg
maximum Working Capacity .................................... 15ltr
minimum Working Capacity .......................................7ltr
4. operation
Warning!
ensure that you have read, understood and apply the chapter 1 safety instructions before using the cleaning tank.
4.1.
Check that the washer power switch is in the off position, and that the unit is unplugged from the mains power supply.
4.2.
Check that the lid will close under its own weight by opening fully and releasing. Free up if necessary.
4.3.
open the lid fully and ensure the “over centre” link engages (fig.1 and fig.2). Fill the tank to appropriate capacity; between a minimum
of 7ltrs and a maximum of 15ltrs with a Sealey solvent or a general purpose degreaser. Contact your local Sealey stockist for supply.
Do not
use any other type of solvent.
caution!
ensure that you follow any instructions provided with the solvent.
4.4.
If fitted, remove the internal tray to ensure the pump is immersed correctly in the solvent. Replace the internal tray.
4.5.
Plug the unit into the mains power supply and switch the unit on (fig.3). Check that the solvent flows freely through the flexible spout.
4.6.
Place parts to be cleaned onto the internal cleaning tray. Ensure any splash back stays inside the tank. For ground-in dirt etc, leave
the parts to soak in the bottom of the tank. Brush parts with the cleaning brush if required. Turn off the pump and leave the parts to
drain on the shelf.
4.7.
When complete, turn the washer off and unplug from the mains power supply.
Warning! Do not
allow uncontrolled discharge of fluids, thus polluting the environment. dispose of waste liquids according to local
authority regulations.
4.8.
Keep the cleaning tank clean. Remove and clean the filter regularly (fig.4) for the best and safest performance.
n.b.
This cleaning tank has an anti-fire device built into it (fig.1 and fig.2). In the event of a fire and subsequent increase in
temperature locally, the low melting point solder in the fusible links turns from solid to liquid allowing the lid to close under gravity.
Do not
prop the lid open with anything other than the fitted fused linkage. Use your finger (fig.2) to ensure full engagement. once
actuated, the fire detection device cannot be re-used and must be replaced. When cleaning parts ensure that nothing in the tank,
including the parts basket and the flexible spout, is in a position that would prevent the lid from closing fully, if and when the fusible
link activates.
Sm21.V4 | Issue 2 26/03/18
Original Language Version
© Jack Sealey limited