background image

 

8

  

Do not 

leave the cleaning tank operating unattended.

 

8

  

Do not

 operate the cleaning tank when you are tired, under the influence of alcohol, drugs or intoxicating medication.

 

9

   The tank is not suitable for paint thinners, gun wash or air drying.

 

9

   When not in use switch the cleaning tank off, remove plug from the power supply. 

 

9

   dispose of waste liquids in accordance with local authority regulations.

 

‰

  

Warning! Do not

 allow uncontrolled discharge of fluids thus polluting the environment.

2.  introDuction

 

One-piece tank with triple baked finish and fully sealed magnetic drive pump unit with replaceable impeller. Smaller capacity tank   

 

is suitable for benchtop mounting. Recirculated fluid is filtered before entering the pump and is directed over the workpiece with a  

 

flexible metal delivery nozzle. Removable shelf included.

3.  specification

        model no ......................................................... Sm21.V4

        overall Height .................................................... 225mm

        Tank Height  ....................................................... 210mm

        Tank depth ......................................................... 290mm

        Tank Width ............................................................... 395

        Pump output/hr ....................................................... 90ltr

        motor Power ............................................................26W

        Supply ....................................................................230V

        Weight .................................................................6.88Kg

        maximum Working Capacity .................................... 15ltr

        minimum Working Capacity .......................................7ltr

4.  operation

 

‰

  

Warning!

 ensure that you have read, understood and apply the chapter 1 safety instructions before using the cleaning tank.

4.1.    

Check that the washer power switch is in the off position, and that the unit is unplugged from the mains power supply.

4.2.    

Check that the lid will close under its own weight by opening fully and releasing. Free up if necessary. 

4.3.    

open the lid fully and ensure the “over centre” link engages (fig.1 and fig.2). Fill the tank to appropriate capacity; between a minimum  

 

of 7ltrs and a maximum of 15ltrs with a Sealey solvent or a general purpose degreaser. Contact your local Sealey stockist for supply. 

  

Do not

 use any other type of solvent. 

caution! 

ensure that you follow any instructions provided with the solvent. 

4.4.    

If fitted, remove the internal tray to ensure the pump is immersed correctly in the solvent. Replace the internal tray.

4.5.    

Plug the unit into the mains power supply and switch the unit on (fig.3). Check that the solvent flows freely through the flexible spout.

4.6.    

Place parts to be cleaned onto the internal cleaning tray. Ensure any splash back stays inside the tank. For ground-in dirt etc, leave   

 

the parts to soak in the bottom of the tank. Brush parts with the cleaning brush if required. Turn off the pump and leave the parts to    

 

drain on the shelf.

4.7.    

When complete, turn the washer off and unplug from the mains power supply. 

 

‰

  

Warning! Do not

 allow uncontrolled discharge of fluids, thus polluting the environment. dispose of waste liquids according to local 

 

  authority regulations.

4.8.    

Keep the cleaning tank clean. Remove and clean the filter regularly (fig.4) for the best and safest performance.

    

n.b. 

This cleaning tank has an anti-fire device built into it (fig.1 and fig.2). In the event of a fire and subsequent increase in  

 

   

  temperature locally, the low melting point solder in the fusible links turns from solid to liquid allowing the lid to close under gravity.

    

Do not

 prop the lid open with anything other than the fitted fused linkage. Use your finger (fig.2) to ensure full engagement. once  

   

  actuated, the fire detection device cannot be re-used and must be replaced. When cleaning parts ensure that nothing in the tank,    

   

  including the parts basket and the flexible spout, is in a position that would prevent the lid from closing fully, if and when the fusible  

   

  link activates.