6.  TROUBLESHOOTING

6.1. 

  

Upon fault of the dehumidifier, please cut off the power supply immediately, unplug the plug and check the following items:

6.2. 

  

If the said methods still fail to eliminate the above problems, please directly contact the manufacturer or agents. 

DO NOT

 disassemble  

 

the dehumidifier, contact Sealey for repairs.

6.3. 

  

It’s normal to hear the sound of the circulation of refrigerant when the dehumidifier runs.

6.4. 

  

It’s normal for the air vent to blow warm air.

6.5. 

  

INFORMATION FOR THE USER:

6.5.1.   

As a precision part, the humidity sensor may be damaged when used in environment filled with strong corrosive gas and heavy dust.

6.5.2.   

As the dehumidifier is non-resistant against explosion, it’s forbidden to be used in environment of special requirements such as that  

 

filled with combustible/explosive gas, dust, chemicals or biological products.

6.5.3.   

Damage caused to the dehumidifier by use in said environment will void the warranty.

6.5.4. 

  

As water may be discharged from the machine after a certain amount of use, attention shall be paid to managing this water.

6.5.5.   

To minimize faults and maximize the lifetime, press the buttons gently.

6.5.6.   

The deviation between the humidity shown on the sensor and the actual humidity is normal, due to impact by the location, environment  

 

and temperature.

6.5.7.   

Since the cooled air is dried by the condenser before being discharged during operation of the dehumidifier, it’s normal for the air   

 

discharged to be hotter than the environment.

6.5.8.   

Since the dehumidifying effect is associated with the temperature and humidity of the environment, the higher the temperature    

 

and humidity of the environment, normally the greater the dehumidifying effect; while the lower the temperature and humidity of the  

 

environment, typically the lower the dehumidifying effect.

Faults

Cause Analysis

S

olutions

Fails to turn on

S

hown as no power

No power to the wall socket.

Check the power supply.

Check the plug plugged in 

properly.

Plug the power supply in the socket.

Check the fuse is not blown.

Replace the fuse.

P

ower Transformer is broken.

Replace the transformer.

S

hown as power on

Environmental humidity lower 

than the set value.

S

et again according to the demand.

If the water tank is installed 

correctly.

Place the water tank in right position.

If the entire machine is defrosting. Wait for the completion of defrosting cycle.

Unfavourable 

dehumidifying effect

If the air inlet/outlet is obstructed.

Remove the obstacle.

If the door and window are open.

Close the door and window.

If the indoor temperature is too low.

D

on’t run the dehumidifier.

Heavy noise

I

f the ground is firm and flat.

R

esettle the dehumidifier.

D

ehumidifier is stood precariously.

R

esettle the dehumidifier.

Water leakage

D

ehumidifier stood on an incline.

M

ove dehumidifier to a level surface.

Drain pipe/outlet obstructed.

Dismantle the front plate to eliminate blockages.

E1

Coil sensor fault

T

urn to timing for defrosting, to cancel system fault 

function.

E

2/E3

Fault of humidity & temperature sensor.

Replace the humidity & temperature sensor.

EE

Refrigerant leakage.

S

tart the machine after. Ask for help from 

professionals if the “EE” signal remains.

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 

unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 

according to local regulations.

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice. 

Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call 

our technical team on [email protected] or 01284 757505.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

SDH50.V3  Issue 1 30/03/2021

Original Language Version

© Jack Sealey Limited

Summary of Contents for SDH50.V3

Page 1: ...se recommended parts only Unauthorised parts may be dangerous and will invalidate the warranty 8 DO NOT stand or place any object less than 10cm from the front or rear of the unit 8 DO NOT obstruct the air intakes or outlets of the dehumidifier 8 DO NOT place any object into the outlets the unit has a fan running at high speed contact with this will cause injury 8 DO NOT operate the dehumidifier w...

Page 2: ...ironmentally friendly R290 May be connected to a drain hose for continuous operation Mounted on castors for manoeuvrability 3 SPECIFICATION MODEL NO SDH50 V3 CO2 Equivalent 0 0006t Condensate Tank 7L with Auto Shut Off Dehumidifying Capacity 50L day 30 CRH80 Freezing Pressure Max 2 5MPa Global Warming Potential Rating 3 IP Rating IP22 Maximum Airflow 350m hr Power Max Rated 900 750W Refrigerant R2...

Page 3: ...tandby state the LED displays the Full Water signal and the dehumidifier will alarm When the water tank is emptied and put in place again the dehumidifier can continue its performance 5 1 2 CONTINUOUS DRAINAGE As shown in Fig 3 to restore the performance of the water tank you need to take out the water tank and mount the drain pipe Note When using continuous drainage the drainage pipe shall not be...

Page 4: ...t s adjusted to the required value the dehumidifier accepts the new setting and the Timing On icon flickers Ranging from 0 to 24H and 0H as default 5 6 3 Set timer for powering off When it s powered on press the Timing Button As the Timing Off icon flickers and the time set flickers in relevant area press or to adjust the timing The dehumidifier makes a sound once the button is pressed When the ti...

Page 5: ...ormer is broken Replace the transformer Shown as power on Environmental humidity lower than the set value Set again according to the demand If the water tank is installed correctly Place the water tank in right position If the entire machine is defrosting Wait for the completion of defrosting cycle Unfavourable dehumidifying effect If the air inlet outlet is obstructed Remove the obstacle If the d...

Reviews: