Sealey SDH50.V3 Quick Start Manual Download Page 4

5.3. 

  

HUMIDITY CONTROL

5.3.1.   

When the rooms humidity value is 3% lower than the set humidity on the machine, the compressor will shut down, the fan will delay  

 

for 3 minutes and shut down; and when it’s 3% higher than the humidity value set on the machine, both the fan and compressor will  

 operate.

5.3.2. 

  

When the humidity is set at the minimum value, the machines default is to enter the continuous dehumidifying mode.

5.3.3. 

  

Upon fault of the humidity sensor, it turns to the continuous dehumidifying mode.

5.3.4.   

Upon fault of the coil sensor, it turns to the timing defrosting mode (See the defrosting mode).

5.3.5. 

  

When it’s shut down, the fan will run for 10 seconds.

5.4. 

  

PROTECTION FUNCTION

5.4.1.   

Once shut down, the compressor will take 3 minutes to start. Quick start is available for the first power-on.

5.4.2. 

  

Power off memory:

 For abrupt power outage or accidental unplugging, the system will automatically return to the operating state right  

 

before the ‘incident’, and continue at that state for the next power-on.

5.4.3. 

  

Full water protection:

 When the water tank is full, the dehumidifier automatically shuts down and enters the standby state, the    

 

indicator light “Full Water” on and buzzer alarms.

5.5. 

  

DEFROSTING MODE

5.6. 

  

TIMING AND ON/OFF FUNCTION

5.6.1.   

When the machine is powered on, set timer for powering off; and when the machine is powered off, set timer for it to power on. Setting  

 

timer for both powering on and off then initiates the cycle timer mode.

5.6.2. 

  

Set timer for powering on:

 When it’s powered off, press the “Timing” Button. As the “Timing On” icon flickers and the time set flickers  

 

in relevant area, press “+” or “-” to adjust the timing. The dehumidifier will make a sound once the button is pressed. When the time set  

 

increases or decreases by “1”, holding the button for 2 seconds will continually increase or decrease the time. For non-action for 10s  

 

when it’s adjusted to the required value, the dehumidifier accepts the new setting and the “Timing On” icon flickers (Ranging from 0 to  

 

24H, and 0H as default);

5.6.3. 

  

Set timer for powering off:

 When it’s powered on, press the “Timing” Button. As the “Timing Off” icon flickers and the time set flickers  

 

in relevant area, press “+” or “-” to adjust the timing. The dehumidifier makes a sound once the button is pressed. When the time set  

 

increases or decreases by “1”, holding the button constantly for 2s can continually increase or decrease the time. For non-action for  

 

10s when it’s adjusted to the required value, the dehumidifier accepts the new setting and the “Timing Off” icon flickers (Ranging from  

 

0H to 24H, and 0H as default);

Defrosting mode

Description

Automatic Defrosting

S

ensor at normal state

1. The compressor constantly run over 20 minutes, coil temperature below 

0°C constantly over 30 minutes, it starts the defrosting mode.

2. Coil temperature over 5°C for a 90 second period, or defrosting time over 

8 minutes, it has stopped defrosting mode.

Defrosting faults

Coil sensor faults  

(E1 displayed)

1. When the ambient temperature is over 25°C, it will not start a defrosting 

cycle;

2. When ambient temperature below than 25°C but higher than 15°C, the 

compressor runs constantly for 30 minutes, it defrosts for 10 minutes of that 

30 minute period;

3. When ambient temperature below than 15°C and higher than 4°C, 

compressor runs constantly 20 minutes, it defrosts 12 minutes;

Temp-damp sensor faults

1. The compressor runs constantly over 20 minutes, coil temperature below 

0°C constantly run over 20 minutes, it starts defrosting mode.

C

oil sensor and temp-damp 

sensor faults

1. The compressor run constantly over 40 minutes, it defrosts 10 minutes;

2. Coil temperature over 5°C constantly over 90 seconds; or defrosting time 

over 25 minutes, it stops defrosting mode.

A

Power Indicator Light

B

W

ater Tank Full Indicator Light

C

T

imer Indicator Light

D

O

n/Off Set

E

Set Timer

F

A

dd to Set Time

G

R

educe Set Time

SDH50.V3  Issue 1 30/03/2021

Original Language Version

© Jack Sealey Limited

Summary of Contents for SDH50.V3

Page 1: ...se recommended parts only Unauthorised parts may be dangerous and will invalidate the warranty 8 DO NOT stand or place any object less than 10cm from the front or rear of the unit 8 DO NOT obstruct the air intakes or outlets of the dehumidifier 8 DO NOT place any object into the outlets the unit has a fan running at high speed contact with this will cause injury 8 DO NOT operate the dehumidifier w...

Page 2: ...ironmentally friendly R290 May be connected to a drain hose for continuous operation Mounted on castors for manoeuvrability 3 SPECIFICATION MODEL NO SDH50 V3 CO2 Equivalent 0 0006t Condensate Tank 7L with Auto Shut Off Dehumidifying Capacity 50L day 30 CRH80 Freezing Pressure Max 2 5MPa Global Warming Potential Rating 3 IP Rating IP22 Maximum Airflow 350m hr Power Max Rated 900 750W Refrigerant R2...

Page 3: ...tandby state the LED displays the Full Water signal and the dehumidifier will alarm When the water tank is emptied and put in place again the dehumidifier can continue its performance 5 1 2 CONTINUOUS DRAINAGE As shown in Fig 3 to restore the performance of the water tank you need to take out the water tank and mount the drain pipe Note When using continuous drainage the drainage pipe shall not be...

Page 4: ...t s adjusted to the required value the dehumidifier accepts the new setting and the Timing On icon flickers Ranging from 0 to 24H and 0H as default 5 6 3 Set timer for powering off When it s powered on press the Timing Button As the Timing Off icon flickers and the time set flickers in relevant area press or to adjust the timing The dehumidifier makes a sound once the button is pressed When the ti...

Page 5: ...ormer is broken Replace the transformer Shown as power on Environmental humidity lower than the set value Set again according to the demand If the water tank is installed correctly Place the water tank in right position If the entire machine is defrosting Wait for the completion of defrosting cycle Unfavourable dehumidifying effect If the air inlet outlet is obstructed Remove the obstacle If the d...

Reviews: