GENERAL SAFETY CONTINUED:
7
DO NOT
operate within the vicinity of flammable liquids,
gases or solids.
7
DO NOT
touch compressor cylinder, cylinder head or pipe
from head to tank as these may be hot.
7
DO NOT
use this product to perform a task for which it has
not been designed.
7
DO NOT
deface the certification plate attached to the
compressor tank.
7
DO NOT
cover the compressor or restrict air flow around the
unit whilst operating.
q
DANGER! DO NOT
direct the output jet of air towards
people or animals.
7
DO NOT
operate the compressor without an air filter.
7
DO NOT
allow anyone to operate the compressor unless
they have received full instructions.
WARNING!
The air tank is a pressure vessel and the
following safety measures apply:
7
No welding operations are to be carried out on any
pressurised parts of the vessel.
7
DO NOT
tamper with the safety valve,
DO NOT
modify or alter
the tank in any way and
DO NOT
strap anything to the tank.
7
DO NOT
subject the tank to impact, vibration or to heat and
DO NOT
allow contact with abrasives or corrosives.
3
Drain condensation from tank and inspect inside walls for
corrosion as per the maintenance schedule and have a
detailed tank inspection carried out annually. The tank shell
must not fall below the certified thickness at any point.
WARNING!
If an electrical fuse blows, ensure it is replaced
with an identical fuse type and rating.
3
When not in use for a prolonged period, and if possible, store
the compressor carefully in a safe, dry, childproof location.
SPECIFICATIONS
Model: ..........................................SAC4505555B ..........SAC5507575B
Motor Output (HP): ........................5.5hp (x2) ..........................7.5hp (x2)
Voltage/Phase: ..............................415-3hp ................................415-3ph
Input current: .................................32A ..............................................32A
Speed (rpm): .................................1270 ..........................................1280
Air Displacement (cfm/Lm): ...........42.3(1200) ....................... 58.6(1660)
Max Free Air Delivery (cfm/Lm): ....33.9(960) ......................... 45.2(1280)
Max Pressure (psi/bar): .................145/10 ....................................145/10
Tank Capacity (L): .........................500 ..............................................500
Dimensions (WxDxH) (mm): ..........2000x700x1140 ....... 2000x700x1230
Net Weight (kg): ............................245 ..............................................300
3.1.
Remove compressor from packaging and inspect for any
shortages or damage. If anything is found to be missing or
damaged, contact your supplier.
3.2.
Save the packing material for future transportation of the
compressor. It is recommended that the packing is stored in a
safe location, at least for the period of the guarantee. Then, if
necessary, it will be easier to send the compressor to the
service centre.
3.3.
Confirm that the mains voltage corresponds with the voltage
shown on the compressor data plate. Fit a suitable 3 pin
industrial plug - see section 1.1.10. of the Safety Instructions.
3.4.
Take care to transport the compressor correctly, do not
overturn it or lift it with hooks or ropes.
3.5.
Position the compressor on a flat surface and ensure it is
securely bolted down. Site in a well ventilated area, protected
against atmospheric pollution and not in a place subject to
explosion hazard.
3.6.
To ensure good ventilation and efficient cooling, the compressor’s
belt guard must be at least 100cm from any wall (fig.1).
3.7.
Remove the plastic transit plug from the oil filler hole, if fitted,
(fig.2) and replace it with the dipstick. It is a push fit.
3.8.
Before using the compressor, check the oil level on the
dipstick in fig.2. If the oil is not up to the max. mark, it should
be topped up with synthetic oil (see section 5.7. for
recommended oils). We do not recommend using mineral oil in
these compressors. Do not overfill.
fig.1
2. INTRODUCTION
3. PREPARATION
fig.2
fig.3
High output units suitable for the professional workshop. Both units
are fitted with two genuine 3ph motors (either 5.5hp or 7.5hp) which
maximize performance to keep running costs low compared to single
stage, single phase models. Both units have two pumps which have
heavy-duty full cast cylinders, capped by alloy heads for improved
heat dissipation and long life. Heavy-duty drive guards protect belt
and flywheel that is designed to force air over the pump to aid cooling.
Supplied with full CE certification, test certificates and
operating/maintenance manual.