Page 1: ...ectrician 1 1 10 A 32amp supply is required and we recommend that a 32amp industrial round pin plug should be fitted and connected to a 32amp supply having a Type C breaker If in doubt you must contact a qualified electrician to ensure that a suitably rated supply is available IMPORTANT The use of extension leads to connect these compressors to the mains is not recommended as the resulting voltage...

Page 2: ...essor from packaging and inspect for any shortages or damage If anything is found to be missing or damaged contact your supplier 3 2 Save the packing material for future transportation of the compressor It is recommended that the packing is stored in a safe location at least for the period of the guarantee Then if necessary it will be easier to send the compressor to the service centre 3 3 Confirm...

Page 3: ... 3 Turn switch B to start the compressor position 1 is compressor unit 1 operating only position 2 is compressor unit 2 operating only position 3 is both compressor units operating at the same time at staggered starting times 4 4 When starting the compressor for the first time leave it running with no air tools connected to the air outlet Make sure that the pressure in the tank rises and that the ...

Page 4: ...703534 sales sealey co uk Sole UK Distributor Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR www sealey co uk W e b email fig 7 fig 8 Fault Cause Remedy Pressure drop in the tank Air leaks at connections Run compressor to max pressure switch off Brush soap solution over connections and look for bubbles Tighten connections showing leaks If problem persists contact A...