background image

 

9

   Use the compressor in a well ventilated area and ensure it is placed on a firm surface.

 

9

   Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.

 

9

   Ensure the air hose is not tangled, twisted or pinched.

 

9

   Keep children and unauthorised persons away from the working area.

 

8

   DO NOT

 disassemble compressor for any reason. The unit must be checked by qualified personnel only.

 

8

   DO NOT 

use the compressor outdoors, or in damp, or wet, locations.

 

8

  

DO NOT

 operate within the vicinity of flammable liquids, gases or solids.

 

8

  

DO NOT

 touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot.

 

8

 

  DO NOT 

use this product to perform a task for which it has not been designed.

 

8

  

DO NOT 

deface the certification plate attached to the compressor tank.

 

8

   DO NOT

 cover the compressor or restrict air flow around the unit whilst operating.

 

  

DANGER! DO NOT

 direct the output jet of air towards people or animals.

 

8

   DO NOT

 operate the compressor without an air filter.

 

8

   DO NOT

 allow anyone to operate the compressor unless they have received full instructions.

 

‰

   WARNING! 

The air tank is a pressure vessel and the following safety measures apply:

 

8

  

DO NOT

 tamper with the safety valve, 

DO NOT

 modify or alter the tank in any way and 

DO NOT

 strap anything to the tank.

 

8

  

DO NOT

 subject the tank to impact, vibration or to heat and 

 

8

  

DO NOT

 allow contact with abrasives or corrosives.

 

9

  

Drain condensation from tank daily and inspect inside walls for corrosion every three months and have a detailed tank inspection    

  carried out annually. The tank shell must not fall below the certified thickness at any point. 

 

‰

  

WARNING!

 For this reason 

DO NOT

 tamper with, or adjust, the pre-set switch or safety valve.

 

9

   Should there appear to be any loss of efficiency when using the compressor, ensure first that the air tool is clean and functioning   

  properly. If the air tool is satisfactory then refer to the trouble shooting guide.

1.3.   

 

INSPECTION OF PRESSURE TANK BOTH INTERNAL AND EXTERNAL.

 

Under the 

PRESSURE SYSTEMS SAFETY REGULATIONS 2000

 it is the responsibility of the owner of the compressor to initiate a   

 

system of inspection that both defines the frequency of the inspection and appoints a person who has specific responsibility for 

 

carrying out the inspection.

 

8

   DO  NOT

 carry out any welding operations on any pressurised parts of the vessel.

 

‰

   WARNING! 

If an electrical fuse blows, ensure it is replaced with an identical fuse type and rating.

 

 

9

   When not in use, store the compressor carefully in a safe, dry, childproof location.

2.  INTRODUCTION

 

Low noise compressor runs at only 79dB(A), suitable for places where a standard compressor would disturb work or people in the  

 

vicinity. Aluminium cylinder head with cast iron cylinder gives added resistance to wear. Ideal for use where an oil free air delivery is  

 

required. Suitable for general purpose workshop applications.

3.  SPECIFICATION

4.  PREPARATION AND ASSEMBLY

4.1.   

 

Remove compressor from packaging and inspect for any shortages or damage. If anything is found to be missing or damaged contact  

 

your supplier.

4.2.   

 

Confirm that the mains voltage corresponds with the voltage shown on the compressor data plate.

4.3.   

 

The compressor should be installed on a flat surface, or one that does not exceed 10° either transversely or longitudinally, and should  

 

be in a position that allows good air circulation around the unit. 

Model No:

SAC0607S

SAC2410S

SAC5016S

A

ir Displacement cfm(L/min)

3.1(89)

5.3(150)

6.9(196)

M

aximum Free Air Delivery cfm(L/min):

1.6(44)

2.6(73)

3.4(97)

Maximum Pressure: psi(bar)

116(8)

116(8)

116(8)

Minimum Rated Supply:

230V

230V

230V

Motor Output: hp

0.7

1

1.6

Outlet:

Quick Release Coupling Quick Release Coupling

Quick Release Coupling

Phase:

1ph

1ph

1ph

Plug Type:

3-Pin BS

3-Pin BS

3-Pin BS

Receiver Capacity: L

6

24

50

Size (W x D x H):

460 x 230 x 510mm

610 x 290 x 640mm

730 x 320 x 700mm

Supply:

230V

230V

230V

Noise level:

79dB(A)

ION AND A

79dB(A)

79dB(A)

S

AC0607S, SAC2410S, SAC5016S     Issue 1    09/03/21

Original Language Version

© Jack Sealey Limited

Summary of Contents for SAC0607S

Page 1: ...h the correct fuse see fuse rating at right 8 DO NOT pull or carry the appliance by the power cable 8 DO NOT pull the plug from the socket by the cable 8 DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician 1 1 7 This product is fitted with a BS1363 A 13 Amp 3 pin plug If the cable or plug is damaged during use switc...

Page 2: ...satisfactory then refer to the trouble shooting guide 1 3 INSPECTION OF PRESSURE TANK BOTH INTERNAL AND EXTERNAL Under the PRESSURE SYSTEMS SAFETY REGULATIONS 2000 it is the responsibility of the owner of the compressor to initiate a system of inspection that both defines the frequency of the inspection and appoints a person who has specific responsibility for carrying out the inspection 8 DO NOT ...

Page 3: ... The required setting once achieved can be locked by screwing the locking ring See fig 2 up tight underneath the adjusting knob 5 8 You can now begin to use the tool The compressor will operate automatically cutting in and out as required to restore the air pressure in the tank The pressure switch fig 2 stops the motor when the maximum tank pressure is reached and restarts it when pressure falls b...

Page 4: ...inutes 6 MAINTENANCE WARNING Before performing any maintenance operation switch off the compressor disconnect from electricity supply and release all air from the tank In order to keep the compressor in good working condition periodical maintenance is essential 6 1 Operations to be carried out daily a Drain condensation by opening the valve located under the tank Place a container under the valve ...

Page 5: ...lure Contact Authorised Service Agent Compressor does not stop at maximum pressure 1 Pressure switch fault 2 Filter clogged 3 Head gasket or valve fault 1 Contact Authorised Service Agent 2 Replace filter element 3 Contact Authorised Service Agent Compressor noisy with metallic knock Bearing or piston damage Contact Authorised Service Agent Excessive moisture in discharged air High humidity enviro...

Reviews: