VEC270MG 

Power Uses—12 Volt 

Cellular Phones 

Lights 

Radios 

Small Appliances 

TVs 

Inflation Uses 

Car Tires 

Bicycle Tires 

Minivan Tires 

Sports Equipment 

Air Mattresses 

 

THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING 
SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS 
PRODUCT. BEFORE USING, READ AND UNDERSTAND ALL CAUTIONS, 
WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR 
VEHICLE’S BATTERY AND INFLATABLE’S MANUFACTURER 
GUIDELINES. FAILURE TO DO SO COULD RESULT IN INJURY AND/OR 
PROPERTY DAMAGE. 

Features 

Compact 

Lightweight 

Portable 

Powerful 

Rugged 

4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312 

TEL 954-584-4446 

 TOLL FREE: 866-584-5504 

 FAX 954-584-5556 

260 PSI AIR COMPRESSOR 

CORDLESS 

y

 RECHARGEABLE 

OWNER’S MANUAL 

& WARRANTY INFORMATION 

 

 

  IMPORTANT SAFETY INFORMATION SAVE THESE INSTRUCTIONS 

Summary of Contents for VEC270MG

Page 1: ...AD AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY AND INFLATABLE S MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE Features Compact Lightweight Portable Powerful Rugged 4140 SW 28TH WAY FT LAUDERDALE FL 33312 TEL 954 584 4446 TOLL FREE 866 584 5504 FAX 954 584 5556 260 PSI AIR COMPRESSOR CORDLESS y RECHARGEABL...

Page 2: ...Page 2 of 16 260 PSI AIR COMPRESSOR CORDLESS y RECHARGEABLE VEC270MG ...

Page 3: ...Recharging 9 3 2 12 Volt DC Recharging 10 3 3 Battery Indicator Lights 10 4 OPERATION AS A PORTABLE COMPRESSOR INFLATOR 10 4 1 Tire Inflation or Products With A Valve Stem 11 4 2 Other Inflatables Without Valve Stem 11 4 3 Typical Inflation Times For Products Without Valve Stems 12 5 OPERATION AS A 12 VOLT PORTABLE POWER SOURCE 12 5 1 Estimated 12 Volt DC Usage Times 12 6 EMERGENCY WORKLIGHT 13 7 ...

Page 4: ...important information that if not followed may cause damage to equipment The following safety precautions must be followed at all times along with any additional existing safety rules 1 2 Charging Instructions For best results charge the battery in temperatures ranging from 65 degrees F 18 degrees C to 75 degrees F 24 degrees C Inflator must be charged at least 24 hours using the 120 volt AC metho...

Page 5: ... plug and not the cord when disconnecting 7 Never operate charger if it has received a sharp blow been dropped or otherwise damaged in any way take it to a qualified service technician or call Vector Customer Service 8 Never disassemble take unit to a qualified service technician or call Vector Customer Service when service or repair is required Incorrect reassembly may result in a risk of electri...

Page 6: ...sition before connection to a power source or load 20 There is a risk of explosive gases being released when lead acid batteries are being charged or discharged Failure to follow instructions may cause property damage explosive hazard and or personal injury 21 DO NOT over inflate tires inflatable items 22 Although this unit contains a sealed non spillable lead acid battery it is recommended to be ...

Page 7: ...Emitting Diode charge indicators that show when the unit is fully charged or the level of charge in the battery Charge level can be viewed when the charge PUSH FOR STATUS button switch is pressed When pressed the CHARGE STATUS button will show the battery s power level status from Low to Full The green LED full indicator illuminates when the unit is fully recharged and charging can be discontinued...

Page 8: ...klight 4 AC Recharge Adapter Barrel Connector Outlet 5 LED Charging Battery Status Indicators 6 Charge Status Push Button 7 12 Volt DC Accessory Outlet with 15 Amp Overload Protection 8 Air Vent 9 Rubberized Handle and Base 10 20 Air Hose and Coupler 11 120 volt UL listed AC DC Charging Adapter Cord 12 DC Charging Adapter Cord 13 Analogue Dial Pressure Gage 12 11 7 3 1 2 6 4 5 8 9 13 ...

Page 9: ...ttery If the unit is used too long after the red light comes on recharging could take up to 7 hours 3 1 120 Volt AC Recharging IMPORTANT The unit s power ON OFF switch MUST be OFF when the unit is charging or not in use To recharge the battery using the 120 volt AC adapter follow these procedures 1 Push the power switch to the Off position and insert the 120 volt AC recharging adapter into the AC ...

Page 10: ...LED is lit this indicates the battery must be recharged The red LEDs will light when recharging the battery 4 OPERATION AS A PORTABLE COMPRESSOR INFLATOR WARNING Do not leave the inflator unattended while the unit is running The universal adapter must be locked to secure the inflation accessories Any misuse could cause property damage or personal injury Use extreme caution when using inflation acc...

Page 11: ...sor switch 5 When the object is firm turn the inflator off 4 1 Tire Inflation or Products With A Valve Stem The built in 12 volt DC 260 PSI Air Compressor is the ultimate compressor for most vehicles trailer tires and recreational inflatables 1 Place connector chuck on valve stem 2 Ensure connector is pushed on to valve stem as far as possible before closing thumb latch 3 Make sure latch is secure...

Page 12: ... recommendations for pressure to be inflated Inflatable Articles Pressure Time From 0 Pressure Football 13 PSI 24 seconds Basketball 9 PSI 20 seconds Volleyball 5 PSI 6 seconds 5 OPERATION AS A 12 VOLT PORTABLE POWER SOURCE NOTICE Make sure that the unit s power ON OFF switch is ALWAYS in the OFF position when using the 12 volt DC accessory outlet The unit s 12 volt power supply can power 12 volt ...

Page 13: ...n the unit is being recharged or stored 7 REPLACEMENT PARTS For replacement parts bulbs batteries fuses etc contact Vector Customer Service 954 584 4446 or toll free 866 584 5504 7 1 Bulb Replacement WARNING Make sure all power is off and unit is disconnected before attempting to remove cover and replace fluorescent tubes Tools needed small Phillips screwdriver 1 Unscrew counterclockwise and remov...

Page 14: ... 877 288 7722 8 SPECIFICATIONS Model VEC270MG Voltage 12 VDC Battery Type s 2 Sealed high energy density AGM lead acid rechargeable maintenance free 6 volt DC 4 5 Amp hour Bulb Twin Tubes 2 Fluorescent Tubes 4 Watts each Accessory Socket Protected by a 15 Amp Fuse Charging Cord 12 volt DC Adapter Charger 120 volt AC 500mA 12 volt DC Output HEIGHT 8 5 in 21 6 cm LENGTH 11 in 27 94 cm WIDTH DEPTH 3 ...

Page 15: ...f the warranty period The customer is responsible for the shipping charges on all returned items after 30 days During the warranty period Vector Manufacturing Ltd will be responsible for the return shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading du...

Page 16: ...ion Card and mail to Vector Manufacturing Enter VEC270MG as Model and 260 PSI AIR COMPRESSOR CORDLESS y RECHARGEABLE as Product Type All Vector Manufacturing Ltd products must be registered within 10 days of purchase to activate this warranty Mail the completed registration card along with a copy of the original sales receipt to ATTN CUSTOMER SERVICE VECTOR MANUFACTURING Ltd 4140 SW 28th Way Fort ...