3.1.  Air Supply  

3.1.1. Ensure screwdriver air valve (or trigger) is in "off" position before connecting to air supply.

3.1.2. You will require an air pressure of 90psi, and an air flow according to specification.

3.1.3. 

 

WARNING!

 Ensure the air supply is clean and does not exceed 90psi while operating  

 

the screwdriver. Too high an air pressure and unclean air will shorten the product life due to 

 

excessive wear, and may be dangerous causing damage and/or personal injury. 

3.1.4. Drain the air tank daily. Water in the air line will damage the screwdriver. 

3.1.5. Clean air inlet filter weekly. Recommended hook-up is shown in fig 1.

3.1.6. Line pressure should be increased to compensate for unusually long air hoses (over 8  

 

metres). The minimum hose diameter should be 1/4” I.D. and fittings must have the same  

 

inside dimensions. 

3.1.7. Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain 

 

that all connections are secure. 

3.2.    Couplings 

3.2.1. Vibration may cause failure if a quick change coupling is connected directly to screwdriver.  

 

To overcome this, connect a leader hose to the screwdriver. A quick change coupling may  

 

then be used to connect the leader hose to the air line recoil hose. See fig 1 & 2. 

3. 

PREPARING SCREWDRIVER FOR USE

4. 

OPERATING INSTRUCTIONS

fig 1

fig 2

 

WARNING!

 Ensure you read, understand and apply safety instructions before use.

 

WARNING!

 Disconnect screwdriver from air supply before changing accessories,    

 

servicing or performing maintenance.

 

DO NOT

 allow screwdriver to free run for an extended period of time as this will shorten its  

 

life.

4.1.

  Push driver bit into self locking chuck (fig.3.A.) and ensure it is secure. To release bit, push  

 

chuck collar (fig.3.B.) forward and pull bit out.

4.2.

  Connect the screwdriver to the air hose as in Section 3.

4.3.

  Check that the screwdriver is set to operate in the required direction. The screwdriver  

 

direction is changed by switching the reverse lever (fig.3.C.) behind the trigger.

Risk of Hand Arm Vibration Injury

Air Pistol Screwdriver Model No. SA58.V2

 when operated in accordance with these instructions and tested in 

accordance with EN 28662-2: 1994 results in the following vibration emission declared in accordance with BS 

EN12096: 1996. 

Measured vibration emission value:  . . . . . . . . . . . 2.0m/sec²

Uncertainty: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0.8

m/s²

These values are suitable for comparison with emission levels of other tools that have been subject to

 

the same test.

This tool may cause hand-arm vibration syndrome if its use is inadequately managed.

Recommended measures to reduce risk of hand-arm vibration syndrome:

This item represents a low Hand Arm Vibration risk to users. The calculated maximum usage period exceeds 8 

hours. We recommend appropriate safety equipment is utilised and regular breaks for the operator are 

employed to reduce any residual risk of fatigue or repetitive strain injury.