6. tROUBLEShOOtiNG  

FAULt

CAUSE

REMEdY

1a)  Pressure drop in the tank.

air leaks at connections.

run  compressor  to  max.  pressure,  switch  off.                   

Brush soap solution over connections and look for 

bubbles. tighten connections showing leaks. 

If problem persists contact authorised service agent.

1B)

 

 Pressure drop in the tank.

air leaks from safety valve.

operate the safety valve manually. If valve 

continues to leak when in the closed position it 

should be replaced.

1c)  Pressure drop in the tank.

air leaks from cylinder head gasket.

check tightness of head bolts. If leak continues 

contact authorised service agent.

2)    Pressure switch valve leaks when 
       compressor is idle.

non-return valve seal defective.

empty the air tank, remove the non-return valve 
cap and clean, or if necessary, replace the seal.

3)     air leaks from tank body or tank welds.

Internal corrosion caused by infrequent tank 

draining or non permitted modifications to tank.

tank could rupture or explode. cannot be repaired. 

diSCONtiNUE USE iMMEdiAtELY.

4a)  motor stops and will not restart.

thermal cut out has operated.

allow to cool for 10 to 15 minutes before restarting.

4B)  motor stops and will not restart.

Plug fuse has burnt out.

replace fuse and restart unit. If repeat 

occurs, contact authorised service agent.

5)     compressor stops and does not restart.

motor failure.

contact authorised service agent..

6a)   compressor does not stop at max. pressure.

Pressure switch fault..

contact authorised service agent.

6B)   compressor does not stop at max. pressure.

filter clogged

clean or replace filter element.

6c)   compressor does not stop at max. pressure.

Head gasket or valve fault.

contact authorised service agent.

7)     compressor noisy with metallic knock.

Bearing or piston damage.

contact authorised service agent.

8)     excessive moisture in discharged air.

High humidity environment.

drain tank after each use.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPORtANt: 

no liability is accepted for incorrect use of this product. 

WARRANtY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

iNFORMAtiON:

 for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK distributor, Sealey Group, 

Kempson Way, suffolk Business Park

Bury st. edmunds, suffolk,
IP32 7ar

www.sealey.co.uk

Web

email

Original Language Version

sa0615    Issue: 2 - 20/02/12

 

   

   Environmental Protection.

  

 recycle unwanted materials instead of disposing of them as waste. all tools, accessories and  

  

 packaging should be sorted, taken to a recycle centre and disposed of in a manner

             which is compatible with the environment.

 
  

 

  

When the product is no longer required, it must be disposed of in an

 environmentally protective way. 

5.6.

 

iMPORtANt WARNiNG

 -

 

Air contaminants taken into the compressor will affect optimum performance. Example: Body filler dust or paint overspray will clog the   

 

pump intake filter and may cause internal damage to pump/motor components. Please note that any parts damaged by any type of    

 

contamination will not be covered by warranty.

Summary of Contents for SA0615

Page 1: ...there are no bare wires that all wires have been correctly connected that the cable outer insulation extends beyond the cable restraint and that the restraint is tight double insulated products which are always marked with this symbol are fitted with live brown and neutral blue wires only to rewire connect the wires as indicated above dO NOt connect either wire to the earth terminal 1 1 10 Product...

Page 2: ...e it should be switched off disconnected from the mains supply and the air drained from the tank Motor output 1 5hp voltage phase 230V 1ph Current 4 8a Air displacement 4 8cfm Max free air delivery 3 4cfm tank capacity 6ltr Max pressure 116psi 8bar Noise level 95dB a Original Language Version sa0615 Issue 2 20 02 12 4 OPERAtiON WARNiNG ENSURE thAt YOU hAvE REAd UNdERStOOd ANd APPLiEd SECtiON 1 SAF...

Page 3: ... sae 5W50 viscosity alternatively a mineral oil can be substituted when carrying out an oil change after ensuring that the synthetic oil has been thoroughly drained first use a mineral oil of sae 15W40 viscosity WARNiNG do not mix different oils and do not use non detergent low quality oils as the compressor may be damaged dispose of all waste oil responsibly in accordance with local authority req...

Page 4: ...logged clean or replace filter element 6c compressor does not stop at max pressure Head gasket or valve fault contact authorised service agent 7 compressor noisy with metallic knock Bearing or piston damage contact authorised service agent 8 excessive moisture in discharged air High humidity environment drain tank after each use NOTE It is our policy to continually improve products and as such we ...

Reviews: