6. tROUBLEShOOtiNG
FAULt
CAUSE
REMEdY
1a) Pressure drop in the tank.
air leaks at connections.
run compressor to max. pressure, switch off.
Brush soap solution over connections and look for
bubbles. tighten connections showing leaks.
If problem persists contact authorised service agent.
1B)
Pressure drop in the tank.
air leaks from safety valve.
operate the safety valve manually. If valve
continues to leak when in the closed position it
should be replaced.
1c) Pressure drop in the tank.
air leaks from cylinder head gasket.
check tightness of head bolts. If leak continues
contact authorised service agent.
2) Pressure switch valve leaks when
compressor is idle.
non-return valve seal defective.
empty the air tank, remove the non-return valve
cap and clean, or if necessary, replace the seal.
3) air leaks from tank body or tank welds.
Internal corrosion caused by infrequent tank
draining or non permitted modifications to tank.
tank could rupture or explode. cannot be repaired.
diSCONtiNUE USE iMMEdiAtELY.
4a) motor stops and will not restart.
thermal cut out has operated.
allow to cool for 10 to 15 minutes before restarting.
4B) motor stops and will not restart.
Plug fuse has burnt out.
replace fuse and restart unit. If repeat
occurs, contact authorised service agent.
5) compressor stops and does not restart.
motor failure.
contact authorised service agent..
6a) compressor does not stop at max. pressure.
Pressure switch fault..
contact authorised service agent.
6B) compressor does not stop at max. pressure.
filter clogged
clean or replace filter element.
6c) compressor does not stop at max. pressure.
Head gasket or valve fault.
contact authorised service agent.
7) compressor noisy with metallic knock.
Bearing or piston damage.
contact authorised service agent.
8) excessive moisture in discharged air.
High humidity environment.
drain tank after each use.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPORtANt:
no liability is accepted for incorrect use of this product.
WARRANtY:
Guarantee is 12 months from purchase date, proof of which will be required for any claim.
iNFORMAtiON:
for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
Sole UK distributor, Sealey Group,
Kempson Way, suffolk Business Park
,
Bury st. edmunds, suffolk,
IP32 7ar
www.sealey.co.uk
Web
Original Language Version
sa0615 Issue: 2 - 20/02/12
Environmental Protection.
recycle unwanted materials instead of disposing of them as waste. all tools, accessories and
packaging should be sorted, taken to a recycle centre and disposed of in a manner
which is compatible with the environment.
When the product is no longer required, it must be disposed of in an
environmentally protective way.
5.6.
iMPORtANt WARNiNG
-
Air contaminants taken into the compressor will affect optimum performance. Example: Body filler dust or paint overspray will clog the
pump intake filter and may cause internal damage to pump/motor components. Please note that any parts damaged by any type of
contamination will not be covered by warranty.