background image

3.1.  air supply

 

3 .1 .1 . Ensure tool valve (or trigger) is in the "off" position before connecting to the air supply .

3 .1 .2 . You will require an air pressure of 90psi, and an air flow according to specification .

3 .1 .3 . 

 

WarninG! 

Ensure the air supply is clean and does not exceed 90psi while operating the

 

tool . Too high an air pressure and unclean air will shorten the product life due to excessive 

 

wear, and may be dangerous causing damage and/or personal injury . 

3 .1 .4 . Drain the air tank daily . Water in the air line will damage the tool . 

3 .1 .5 . Clean air inlet filter weekly . Recommended hook-up procedure is shown in fig .1 .

3 .1 .6 . Line pressure should be increased to compensate for unusually long air hoses (over 8 

 

metres) . The minimum hose diameter should be 1/4” I .D . and fittings must have the same 

 

inside dimensions . 

3 .1 .7 . Keep hose away from heat, oil and sharp edges . Check hose for wear, and make certain 

 

that all connections are secure . 

3.2.    couplings. 

 

Vibration may cause failure if a quick change coupling is connected directly to the tool . To  

 

overcome this, connect a leader hose to the tool . A quick change coupling may then be used  

 

to connect the leader hose to the air line recoil hose . See fig .1 & 2 . 

 

WarninG!

 

Disconnect tool from air supply before changing accessories, servicing or 

 

performing maintenance .

 

Replace or repair damaged parts . 

Use genuine parts only. 

 

Unauthorised parts may be dangerous and will invalidate the warranty.

Note:  Numbers in brackets refer to item numbers in the parts diagram .

5.1.

  To replace the needles (16), unscrew the needle tube (19) from the barrel sleeve (12) .   

 

Remove the needle holder (17) and replace the needles (16) . (Use genuine Sealey needles  

 

only .)  Refit the needle holder (17) into the needle tube (19), screw it onto the barrel sleeve  

 

(12) and tighten .

5.2.

  Lubricate the tool daily with a few drops of Sealey air tool oil dripped into the air inlet .

5.3.

   Clean the tool after use . 

5.4. 

  Loss of power or erratic action may be due to the following: 

 

a)

  Excessive drain on the air line . Moisture or restriction in the air pipe . Incorrect size  

 

  or type of hose connectors . To remedy check the air supply and follow instructions in  

 

  chapter 3 . 

 

b

)  Grit or gum deposits in the tool may also reduce performance .  Flush the tool out  

 

  with gum solvent oil or an equal mixture of SAE No 10 oil and paraffin . 

 

  Allow to dry before use .  

5.5.

  For a full service contact your local Sealey service agent . 

5.6.

  When not in use, disconnect from air supply, clean tool and store in a safe, dry, 

 

childproof location .

 

WarninG! ensure you read, understand and apply safety instructions before use.

note:

  Numbers in brackets refer to item numbers in the parts diagram .

4.1.  flux chipper

4 .1 .1 . Fit the spring (4) onto the rounded end of the chisel (15) before fitting the chisel into the  

 

barrel sleeve (12) .

4 .1 .2 . Fit the nut (20) over the sharpened end of the chisel (15), screw it onto the barrel sleeve  

 

(12) and tighten .

4 .1 .3 . Connect the tool to the air hose as in chapter 3 .

4 .1 .4 . To start the tool, depress the throttle lever . 

4.2.  needle scaler

4 .2 .1 . To use as a needle scaler, unscrew the nut (20) and remove the chisel (15) and spring (4) .

4 .2 .2 . Fit the needle driver (14) and ensure the spring (18) is located in the needle tube (19) .

4 .2 .3 . Ensure the needle holder (17) is fitted with needles (16) such that the heads of the needles  

 

do not protrude above the surface of the needle holder .

4 .2 .4 . Fit the needle holder (17) into the needle tube (19), screw the needle tube (19) onto the  

 

barrel sleeve (12) and tighten .

4 .2 .5 . To start the tool, depress the throttle lever . 

 

do not

 allow the tool to free run for an extended period of time as this will shorten its life .

fig.1

5.  Maintenance

risk of Hand arm Vibration injury. 

The SA52, when operated in accordance with these instructions and tested in accordance with EN 28662-1:     

1993 results in the following vibration emission declared in accordance with  BS EN12096: 1996 . 

Measured vibration emission value:  . . . . . . . . .6 .7m/s2   Uncertainty:   . . . . . . . . . . . . . . 2 .68m/s2

these values are suitable for comparison with emission levels of other tools that have been subject to 

the same test.

this tool may cause hand-arm vibration syndrome if its use is inadequately managed.

recommended Measures to reduce risk of hand-arm vibration syndrome:

This tool should not be used by an individual regularly for more than 

136

 minutes in any 8 hour period .

This duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources .

We, the sole importer into the UK, declare that the product listed here is in conformity with the 

following standards and directives . The construction file for this product is held by the Manufacturer 

and may be inspected, by a national authority, upon request to Jack Sealey Ltd .

For Jack Sealey Ltd. Sole importer into the 

UK of Sealey Power Tools.

 air fLuX cHiPPer/needLe scaLer

Model: sa52

2006/42/EC Machinery Directive

93/68/EEC Marking Directive

11th September 2009

declaration of conformity 

Signed by Mark Sweetman

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component 

parts without prior notice. 

iMPortant: 

No liability is accepted for incorrect use of this equipment . 

Warranty: 

Guarantee is 12 

months from purchase date . proof of which will be required for any claim . 

inforMation: 

For a copy of our latest catalogue and 

promotions, call us on 01284 757525 and leave your full name and address including your postcode .

01284 757500

01284 703534

[email protected]

sole uK distributor

sealey Group,

Bury St . Edmunds, Suffolk .

www.sealey.co.uk

Web

email

4.  oPeratinG instructions

3. 

PreParinG tooL for use

fig.2

SA52     Issue No: 3 - 170909

SA52     Issue No: 3 - 170909