background image

 

8

  

Do not

 over-fill fuel tank. Always leave room for fuel to expand.

 

8

  

Do not

 operate in the rain.

 

  

Danger

! do not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase    

  the risk of personal injury and/or equipment damage. the generator supplies the correct rated frequencies and voltage only  

  when running at the correct governed speed. incorrect frequency and/or voltage can damage some connected electrical    

  loads. operating at excessively low speeds may result in shortened engine life. over-speeding will invalidate the warranty.

 

8

  

Do not

 operate the generator when you are tired, or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

Do not

 store generator with fuel in tank where petrol vapours might reach an open flame or spark.

2.  IntroDuctIon

Heavy duty frame design provides full protection and portability. suitable for running power tools and lighting units. long running with 

up to 12 hours on a full tank. fitted with two 230V 16A and two 110V 16A sockets. Powerful and reliable generator. smooth running 

unit fitted with anti-vibration engine mounts. Features low oil warning light, overload protection and fuel gauge.

3.  SpecIfIcatIon

model no: .................................................................... G5501

motor power: .................................................................. 13hp

motor type: ...................................................... 4-stroke petrol

output: ...................................................... 230V/110V - 50Hz

current rating: .............................................................16/16A

continuous power rating: ...................................5000/3500W

maximum power rating: ......................................5500/4000W

fuel capacity: ..................................................................25ltr

maximum running time: ................................................... 11hr

noise rating: .............................................96dB, 88dB@ 7mtr

dry weight: ..................................................................... 77kg

dimensions (W x d x H): .........................685 x 540 x 535mm

1 tank indicator

2 tank cap

3 2 x 110V~ sockets

4 earth connection

5 overload cut-out switch

6 2 x 230V

˷

 sockets

7 Oil filler screw

8 oil drainage screw

9 oil shortage cut-out

9A oil shortage alarm light

10 on/off switch

11 choke lever

12 recoil starter

13 Petrol tap

14 Wheels

15 Axle

16 foot

17 Push bar holder

18 Push bar

19a screw m8x40

19b screw m8x25

20 screw m8x16

21 Washers for wheels

22 split pins for wheels

23 nuts m8

24 screwdriver

25 spark plug spanner

26 Oil filler funnel

27 change over switch 110V˜/230V

˷

28 2 x 230V

˷

 sockets

29 Voltmeter

Original Language Version

© Jack sealey limited

1

2

3

G5501 | issue 2(sP)- 08/11/16

Summary of Contents for G5501

Page 1: ...fire or an explosion No user performed modifications including venting of the exhaust and or cooling ventilation will eliminate the danger DANGER If this unit is used for back up power in the event of a commercial power failure the following steps must be taken Before connecting the generator to the electrical system open the main circuit breaker to isolate the generator and system from the commer...

Page 2: ...ull tank Fitted with two 230V 16A and two 110V 16A sockets Powerful and reliable generator Smooth running unit fitted with anti vibration engine mounts Features low oil warning light overload protection and fuel gauge 3 specification Model no G5501 Motor power 13hp Motor type 4 stroke petrol Output 230V 110V 50Hz Current rating 16 16A Continuous power rating 5000 3500W Maximum power rating 5500 40...

Page 3: ...Original Language Version Jack Sealey Limited 4 5 6 7 8 9 11 10 G5501 Issue 2 SP 08 11 16 ...

Page 4: ...onnect one end of a cable to the earth connection on the generator see fig 3 4 and the other end to an external earth for example an earthing rod 6 operation Important You must fill up with engine oil approx 1 1ltr and fuel before you can start the engine See 7 4 and fig 10 Oil shortage light will illuminate if engine oil is low see fig 3 9A 6 1 Make sure that the generator has sufficient ventilat...

Page 5: ...e event of unusual vibrations or noise If the engine appears to be overloaded or misfires 7 1 Cleaning 7 1 1 Keep all safety devices air vents and the motor housing free of dirt and dust as far as possible 7 1 2 Wipe the equipment with a clean cloth or blow it with compressed air at low pressure 7 1 3 We recommend that you clean the device immediately each time you have finished using it Clean the...

Page 6: ...nds Suffolk IP32 7AR www sealey co uk sales sealey co uk 01284 757500 01284 703534 Web Environmental Protection Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal d...