ON-GUN DIGITAL PRESSURE REGULATOR/
GAUGE
MODEL NO:
ARD01.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING!
Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using
this equipment.
WARNING!
Disconnect the equipment from the air supply before changing accessories,servicing or performing any maintenance.
9
Keep the equipment clean and maintain it in good condition (use an authorised service agent).
9
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
WARNING!
Ensure that the correct air pressure is maintained and not exceeded.
9
Keep air hoses away from heat, oil and sharp edges. Check hoses for wear before each use and ensure that all
connections are secure.
8
DO NOT
direct air from the air hose at yourself, others or animals.
8
DO NOT
operate air tools when tired or under the influence of drugs, alcohol or intoxicating medication.
9
Drain the compressor air tank and the filter bowl daily. Water in the air line will damage your equipment.
9
When work is complete ensure that the air supply is turned off.
2. INTRODUCTION
On/Off button with adjustable auto-off function for extended battery life. Small and compact with composite body. Pressure can be
displayed in psi, bar, kg/cm² or kPa.
3. SPECIFICATION
Model no.: ............................................................. ARD01.V2
M
aximum Pressure:
........160psi/11bar/11.25kg/cm
2
/1100kPa
Maximum Flow: ............................................ 20cfm @ 100psi
4. OPERATION
4.1.
SETTINGS
NOTE:
Unless set otherwise, the gauge automatically shuts off after 60 seconds. To increase this time, see section 4.3.
4.1.1.
Press the on/off button once to switch the gauge on or off.
4.1.2.
Additionally, the on/off button may be used to alter the three function settings.
4.2.
CHANGING THE FUNCTION SETTING
4.2.1.
Ensure that the gauge is not under pressure.
4.2.2.
With the gauge switched on, hold the On button for about 3 seconds, until the display shows ‘---’ then release the button.
4.2.3.
The display will cycle between 0,1, 2, and E.
[-0-] mode resets the gauge to zero.
[-1-] mode resets the automatic shut-off mode.
[-2-] mode resets the pressure units.
[-E-] resetting is completed when “END” shows in display.
4.2.4.
Press the button to enter one of the modes.
4.3.
RESET TO ZERO
4.3.1.
Ensure that the gauge is not under pressure.
4.3.2. Select mode 0 and the display will show 00-.
4.3.5.
Press the button again and the display will show 000.
ARD01.V2 Issue 2 07/07/21
Original Language Version
© Jack Sealey Limited