Appendix B – Handling Instructions  

ESD Warnings 
Electrostatic Discharges (ESD) 

 

A sudden electrostatic discharge can destroy sensitive components. Proper packaging and 
grounding rules must therefore be observed. Always take the following precautions: 
Transport boards and cards in electrostatically secure containers or bags.  

 

Keep electrostatically sensitive components in their containers, until they arrive at an 
electrostatically protected workplace.  

 

Only touch electrostatically sensitive components when you are properly grounded.  

 

Store electrostatically sensitive components in protective packaging or on anti-static mats.  

Grounding Methods  

The following measures help to avoid electrostatic damages to the device:  
 

 

Cover workstations with approved antistatic material. Always wear a wrist strap connected to a 
properly grounded workplace. 

 

Use antistatic mats, heel straps, and/or air ionizers for more protection.  

 

Always handle electrostatically sensitive components by their edge or by their casing.  

 

Avoid contact with pins, leads, or circuitry.  

 

Turn off power and input signals before inserting and removing connectors or connecting test 
equipment.  

 

Keep work area free of non-conductive materials such as ordinary plastic assembly aids and 
Styrofoam.  

 

Use field service tools such as cutters, screwdrivers, and vacuum cleaners that are conductive

.  

 

 

 

Summary of Contents for ULTRA COMM+8.PCIe

Page 1: ...1 Sealevel Systems Inc 7803e Manual SL9250 11 2022 COMM 8 PCIe User Manual 7803e...

Page 2: ...STALLATION 8 Windows Installation 8 Linux Installation 9 Upgrading to the Current SeaCOM Driver 10 Linux Support 10 TECHNICAL DESCRIPTION 11 RS 232 CA 202 DB 25 CONNECTOR PIN ASSIGNMENTS 11 RS 232 68...

Page 3: ...s modems data entry terminals and plotters The COMM 8 PCIe will operate on x1 x4 x8 or x16 PCIe bus slots Features OXPCIe958 buffered UART with 128 byte FIFOs Oscillator and clock prescaler support wi...

Page 4: ...andard Height PC Bracket CA202 68 pin to 8 DB25 Male Cable Advisory Conventions Warning The highest level of importance used to stress a condition where damage could result to the product or the user...

Page 5: ...y to find one or more of the following items useful with the COMM 8 PCIe All items can be purchased from our website www sealevel com by calling our sales team at 864 843 4343 Terminal Block Kit Item...

Page 6: ...xpress slot It is available in standard height PCI Express as item 7803eS 68 PIN Board Connector The board integrates a 68 pin female connector for interfacing the eight serial ports via the included...

Page 7: ...ck divisor to provide a wide range of possible baud rates Note that there are many combinations that can give the same result e g Prescaler 1 and Divisor 8 Prescaler 2 and Divisor 4 or Prescaler 8 and...

Page 8: ...rmation presented on the screens that follow 5 A screen may appear with text similar to The publisher cannot be determined due to the problems below Authenticode signature not found Please click the Y...

Page 9: ...to extract the tar gz file In addition the software selectable interface settings can be accessed by referencing seacom utilities 7803emode For additional software support including QNX please call S...

Page 10: ...Remove Programs list In Vista and newer OSs it will be found in the Programs and Features list 3 Navigate to the Device Manager and remove the Sealevel adapter by right clicking on the line item choo...

Page 11: ...n be changed to match the depth of these UARTs RS 232 CA 202 DB 25 CONNECTOR PIN ASSIGNMENTS Signal Name Pin Mode GND Ground 7 TD Transmit Data 2 Output RTS Request To Send 4 Output DTR Data Terminal...

Page 12: ...IN Port 1 2 3 4 5 6 7 8 TD 1 9 19 27 35 43 53 61 RD 2 10 20 28 36 44 54 62 RTS 3 11 21 29 37 45 55 63 CTS 4 12 22 30 38 46 56 64 DTR 5 13 23 31 39 46 57 65 DSR 6 14 24 32 40 48 58 66 DCD 7 15 25 33 41...

Page 13: ...58 F 50 to 105 C 58 to 221 F Humidity Range 10 to 90 R H Non Condensing 10 to 90 R H Non Condensing Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100 el...

Page 14: ...r help in choosing an I O address and IRQ 4 Make sure the Sealevel Systems adapter is securely installed in a motherboard slot 5 If you are utilizing an operating system prior to Windows 7 please cont...

Page 15: ...statically sensitive components in protective packaging or on anti static mats Grounding Methods The following measures help to avoid electrostatic damages to the device Cover workstations with approv...

Page 16: ...al Equipment and Data Circuit Terminating Equipment Employing Serial Binary Data Interchange Both implementations are in widespread use and will be referred to as RS 232 in this document RS 232 is cap...

Page 17: ...fined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Figure 1 Asynchronous Communications Bit Diagram This special bit is called th...

Page 18: ...18 Sealevel Systems Inc 7803e Manual SL9250 11 2022 Appendix E Mechanical Drawing...

Page 19: ...d to correct the interference at the user s expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 2...

Page 20: ...nty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prep...

Reviews: