Appendix C – Electrical Interface
RS-485
RS-485 is backwardly compatible with RS-422; however, it is optimized for party line or multi-drop
applications. The output of the RS-422/485 driver is capable of being Active (enabled) or Tri-State
(disabled). This capability allows multiple ports to be connected in a multi-drop bus and selectively polled.
RS-485 allows cable lengths up to 4000 feet and data rates up to 10 Megabits per second. The signal levels
for RS-485 are the same as those defined by RS-422. RS-485 has electrical characteristics that allow for 32
drivers and 32 receivers to be connected to one line. This interface is ideal for multi-drop or network
environments. RS-485 tri-state driver (not dual-state) will allow the electrical presence of the driver to be
removed from the line. Only one driver may be active at a time and the other driver(s) must be tri-stated.
RS-485 can be cabled in two ways, two wire and four wire mode. Two-wire mode does not allow for full
duplex communication and requires that data be transferred in only one direction at a time. For half-duplex
operation, the two transmit pins should be connected to the two receive pins (Tx+ to Rx+ and Tx- to Rx-).
Four wire mode allows full duplex data transfers. RS-485 does not define a connector pin-out or a set of
modem control signals. RS-485 does not define a physical connector.