SeaLevel C4-104.ULTRA User Manual Download Page 14

14 

 

© Sealevel Systems, Inc.  3588 Manual   |   SL9008    9/2022 

Electrical Specifications 

Features 

 

Eight 2-wire RS-485 serial ports 

 

16C954 buffered UARTs with 128-byte FIFOs

 

 

Automatic RS-485 enable/disable

 

 

IRQ interrupt status port

 

 

Supports interrupt sharing

 

 

Data rates to 921.6K bps

 

 

Extended temperature range available (-40°C - +85°C)

 

 

Specifications 

Environmental Specifications 

Specification 

Operating 

Storage 

Temperature Range 

0º to 70º C (32º to 158º F) 

-50º to 105º C (-58º to 221º F) 

Humidity Range 

10 to 90% R.H. Non-Condensing 

10 to 90% R.H. Non-Condensing 

 

Power Requirements  

 

Supply line 

+5 VDC 

Rating 

600 mA 

Physical Dimensions 

Board length  

3.775 inches (9.59 cm) 

Board Width 

3.55 inches (9.02 cm) 

 

Manufacturing 

All Sealevel Systems printed circuit boards are built to UL 94V0 rating and are 100% electrically tested. 
These printed circuit boards are solder mask over bare copper or solder mask over tin nickel.  

 

Summary of Contents for C4-104.ULTRA

Page 1: ...1 Sealevel Systems Inc 3588 Manual SL9008 9 2022 SIO 104 8 485 User Manual 3588...

Page 2: ...E YOU GET STARTED 4 HARDWARE SETUP 6 INSTALLATION 9 ELECTRICAL SPECIFICATIONS 14 SPECIFICATIONS 14 APPENDIX A TROUBLESHOOTING 15 APPENDIX B HOW TO GET ASSISTANCE 16 APPENDIX C ELECTRICAL INTERFACE 17...

Page 3: ...ring connections The SIO 104 8 485 is designed to be used with a variety of Operating Systems including Windows 98 NT ME 2000 XP Linux and DOS The SeaCOM API Application Programmer Interface included...

Page 4: ...Conventions Warning The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious injury Important The middle level of importance...

Page 5: ...s a bulkhead mountable DB37 male connector Designed to be used with the CA143 or with a customer supplied DB37 cable DB37F Shielded Cable to 4 DB9M 36 in Length P N CA143 Terminates the DB37 connector...

Page 6: ...nfiguration The board is set up to always share interrupts There is a jumper labeled PD which is located at E1 on the SIO 104 8 485 Setting this jumper enables a 1K ohm pull down biasing resistor requ...

Page 7: ...all data rates will be eight 8 times the selected rate For example if a data rate of 19 2Kbps is selected the actual data rate will be 153 6K bps When using any other OS i e Linux or DOS the following...

Page 8: ...is equipped with 16C954 UARTs that enable the RS 485 drive automatically Line Termination Typically each end of the RS 485 bus must have line terminating resistors The SIO 104 8 485 features a 120 oh...

Page 9: ...emailing support sealevel com to receive access to the proper driver download and installation instructions 1 Begin by locating selecting and installing the correct software from the website SeaCOM so...

Page 10: ...as 7 Zip to extract the tar gz file In addition the software selectable interface settings can be accessed by referencing seacom utilities 3588mode 3rd Party Software Support Third party software sup...

Page 11: ...il the software has been fully installed 1 Turn off PC power Disconnect the power cord 2 Gently insert the SIO 104 8 485 connector noting proper key orientation of the expansion connector on a PC 104...

Page 12: ...1 Ports 5 8 Several cable options are available The following table shows the connector pinout for the 40 pin headers Ports 1 4 J2 PORT PIN RS 485 1 36 DATA 34 DATA 28 GND 2 27 GND 21 DATA 19 DATA 3 1...

Page 13: ...following table Pin Name Signal 1 Data Positive DATA 2 Data Negative DATA 5 Ground GND All pins not listed are no connects DB37 Cabling Option Item number CA110 provides a 6 ribbon cable with a 40 pi...

Page 14: ...nmental Specifications Specification Operating Storage Temperature Range 0 to 70 C 32 to 158 F 50 to 105 C 58 to 221 F Humidity Range 10 to 90 R H Non Condensing 10 to 90 R H Non Condensing Power Requ...

Page 15: ...No two adapters can occupy the same I O address 4 Try the Sealevel Systems adapter with a unique IRQ While the Sealevel Systems adapter does allow the sharing of IRQs many other adapters i e SCSI ada...

Page 16: ...eb site Please refer to this to answer many common questions This section can be found at http www sealevel com faq asp 4 Sealevel Systems maintains a web page on the Internet Our home page address is...

Page 17: ...for 32 drivers and 32 receivers to be connected to one line This interface is ideal for multi drop or network environments RS 485 tri state driver not dual state will allow the electrical presence of...

Page 18: ...f the character is defined by the transmission of a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Asynchronous Communi...

Page 19: ...19 Sealevel Systems Inc 3588 Manual SL9008 9 2022 Appendix E Silk Screen 3588 PCB...

Page 20: ...y Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prepay...

Reviews: