© Sealevel Systems, Inc. 3710 Manual | SL9128 7/2021
Physical Installation
Extreme care should be taken when installing the DIO-104.OPTO
to avoid causing damage to the
connectors. After the adapter is installed, connect your I/O cable to P2. Please note these headers are
keyed so that pin 1 of the cable matches pin 1 of the connector. Refer to Card Setup for information on
setting the address before inserting the
DIO-104.OPTO
onto the stack.
Do not install the Adapter in the machine until the software has been fully installed
1.
Turn off power. Disconnect the power cord.
2.
Remove the case cover (if applicable).
3.
Gently insert the DIO-104.OPTO
connector noting proper key orientation of the expansion
connector on a PC/104 compatible card. The DIO-104.OPTO
adapter is keyed per the current
PC/104 Specification. This will aid in preventing the adapter from being inserted incorrectly.
4.
Mounting hardware (nylon stand-offs and screws) is provided to ensure a good mechanical
connection. Retain any mounting hardware not used to allow for future expansion.
5.
The cables provided are keyed and can be installed before or after the adapter is inserted in the
stack.
6.
Replace the cover.
7.
Connect the power cord and power up the machine.
The DIO-104.OPTO is now ready for use.
3
rd
Party Software
For the most up to date information on third party software support, please visit:
https://www.sealevel.com/support/3rd-party-software-support/