Seagate Surveillance HDD Product Manual, Rev. C
13
www.seagate.com
Drive Specifications
2.8.2 Ambient Temperature
2.8.3 Temperature gradient
2.8.4 Humidity
2.8.4.1
Relative humidity
2.8.4.2
Wet bulb temperature
2.8.5 Altitude
2.8.6 Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mounting
screws. Shock may be applied in the X, Y or Z axis.
2.8.6.1
Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum operating
shock of 70 read / 40 write Gs based on half-sine shock pulses of 2ms during read operations. Shocks should not be
repeated more than 2 times per second.
2.8.6.2
Non-operating shock
8TB & 6TB
The non-operating shock level that the drive can experience without incurring physical damage or degradation in
performance when subsequently put into operation is 300 Gs based on a non-repetitive half-sine shock pulse of
2ms duration.
Operating
0° to 60°C
Non-operating
–40° to 70°C
Operating
20°C per hour (36°F per hour max), without condensation
Non-operating
30°C per hour (54°F per hour max)
Operating
5% to 90% non-condensing (30% per hour max)
Nonoperating
5% to 95% non-condensing (30% per hour max)
Operating
30°C (86°F max)
Non-operating
37.7°C (99.86°F max)
Operating
–61m to 3048m (–200 ft. to 10,000 ft.)
Non-operating
–61m to 12,192m (–200 ft. to 40,000+ ft.)