58
Hawk 4XL Product Manual, Rev. A
Table 13:
“W” models single ended I/O cable 68 conductor signal/contact assignments
Note.
The minus sign next to the signal indicates asserted state is the low voltage of the two levels used for
logic signals
Notes [ ] for Tables 12 through 13.
[1]
See Section 9.7.1 or 9.6.4.2 for detailed electrical characteristics of these signals.
[2]
The conductor number refers to the conductor position when using 0.025-inches (0.635 mm) centerline
flat ribbon cable. Other cables types may be used to implement equivalent contact assignments.
[3]
Connector contacts are on 0.050 inches (1.27 mm) centers.
[4]
“NC” means no connection.
[5]
The conductor number refers to the conductor position (right to left in Figure 15) when using 0.050 inches
(1.27 mm) centerline flat ribbon cable. Other cable types may be used to implement equivalent contact
assignments.
Signal
name [1]
Connector
contact
number [3]
Cable
conductor
number [2]
Connector
contact
number [3]
Signal
name [1]
GND
1
1
2
35
–DB12
GND
2
3
4
36
–DB13
GND
3
5
6
37
–DB14
GND
4
7
8
38
–DB15
GND
5
9
10
39
–DBP1
GND
6
11
12
40
–DB0
GND
7
13
14
41
–DB1
GND
8
15
16
42
–DB2
GND
9
17
18
43
–DB3
GND
10
19
20
44
–DB4
GND
11
21
22
45
–DB5
GND
12
23
24
46
–DB6
GND
13
25
26
47
–DB7
GND
14
27
28
48
–DBP
GND
15
29
30
49
GND
GND
16
31
32
50
GND
TermPwr
17
33
34
51
TermPwr
TermPwr
18
35
36
52
TermPwr
Reserved
19
37
38
53
Reserved
GND
20
39
40
54
GND
GND
21
41
42
55
–ATN
GND
22
43
44
56
GND
GND
23
45
46
57
–BSY
GND
24
47
48
58
–ACK
GND
25
49
50
59
–RST
GND
26
51
52
60
–MSG
GND
27
53
54
61
–SEL
GND
28
55
56
62
–C/D
GND
29
57
58
63
–REQ
GND
30
59
60
64
–I/O
GND
31
61
62
65
–DB8
GND
32
63
64
66
–DB9
GND
33
65
66
67
–DB10
GND
34
67
68
68
–DB11