26
ST15150N/ND/W/WD/WC/DC Product Manual, Rev. D
Figure 9. MYHX temperature measurement locations
5
4
3
1
2
Air-flow cooling
ST15150W drives
single-ended wide
MTBF
800k hours
Card
Component
Reference
case temperature (°C)
MYHX
Polar
1
48
MYHX
Writer
2
64
MYHX
CSAW
3
47
MYHX
Pike
4
52
MYHX
Driver
5
60
HDA housing
Figure 13
The air-flow pattern with which the temperature guidelines above were
generated is shown in Figure 6. Local average air velocities were 0.61 msec
(120 lfpm) and inlet air temperature to the drive was 30°C (86°F), plus a 5°C
temperature rise in the test enclosure (35°C ambient local to the drive).
The maximum allowable HDA case temperature is 60°C.