The default timeout is 10 min.
(3)
Download Current Configuration
Click “Download” to save current configurations.
•
Save:
Click “Save” to save the configu
ration file to local
•
Cancel
: Click “Cancel” to cancel saving the settings.
Note:
The saved .bin file name cannot be changed, otherwise keypad will not be able to restore
the configuration.
(4)
Restore Configuration
•
Select a File
: Click “Select a File” to sel
ect a saved configuration bin file from local PC.
Note:
After selecting the wanted .bin file, it may show fake-path message on the page.
This is designed to hide the .bin file path for protection.
•
Restore
: Click “Restore” to begin to restore the configurati
on from the selected bin file.
Note: Users can customize the config file by adding the name after config, but not able to
delete the config.
(5)
Reset to Default
Click “Reset” to reset the keypad to factory default settings. The following window will pop up
.