Out of measurement range warning
This display appears and an alarm is sounded (for ten seconds) if any of the following
three types of out of measurement range conditions occur.
•
The current water depth exceeds the measurement range.
•
The dive time exceeds 599 minutes.
•
Decompression is required at a decompression stop depth greater than 49 feet
(15 meters).
When a measurement range has been exceeded, the corresponding display shows a
blinking dash (- - -) and the warning is recorded in the
dive log mode
.
After surfacing, the
AQUALAB
dive computer cannot be used for 48 hours, after which
it returns to
surface mode
.
Out of measurement range warning
CAUTION !!
If a decompression stop violation warning is displayed, remember that the displayed
decompression stop times and total ascent time are to be used as a basic guide.
Once this warning is displayed, other warnings (such as an ascent rate warning) are not
shown.
Therefore, be extra careful when ascending, and
be sure to avoid out-of-range conditions
in future dives.