background image

GSM-R5-DIN_User_Manual_EN_v1-11.docx 

 

Strana 2 z 7

 

switched off, after pressing the button Y5 the output will be switched on and after next 
pressing the output will be switched off again. 
 

5.3

 

LED Diodes 

The front panel of 

GSM

 rele

5

 contains indication LED diodes 

PWR

ERR

GSM

 a LED 

diodes for indication inputs (X1, X2, A3, A4) and outputs (Y5, Y6).:  

  

5.4

 

Backup battery 

GSM

 rele

5

 is equipped with backup 3.7 V Li-POL battery which enables to operate the 

GSM

 rele

5

 for several hours  in normal mode in case of a 230 V

AC

 power failure (the 

battery  life  time  depends  on  mode  of  usage).  During  the  battery  supply  mode  the 

GSM

 rele

5

 the 

LED PWR

 blinks at an interval of 1 for 3 seconds. 

In case of failure of the main power supply, the device can send an SMS message. 
The settings are made in 

SeaConfigurator 

– the power supply is listed on the Digital 

inputs tab under the name PWW.  

 

 

 

  

5.5

 

External antenna connector 

GSM

 rele

5

 is supplied with an external antenna GSM-ANT05S with 2,5dB gain. It is not 

recommended  to  put  this  type  of  antenna  on  metal  surface  (the  signal  quality  will 
degrade). If  a 

GSM

 rele

5

 is  used  in  area with  a low GSM signal, it’s possible  to use 

another type of the antenna with higher gain. See other antennas on 

www.seapraha.cz

 
 
 
 
 

6.

 

Configuration 

 

Configuration of the 

GSM

 rele

5

 can be made in several ways. 

 

6.1

 

Default Factory Configuration 

When outputs Y5 or Y6 are switched on/off, the 

GSM

 rele

5

 sends an SMS message to 

the main user (to the telephone number from which it received the first valid command). 
The  input  signal  must  be  stable  for  certain  time  (approx.  1  sec)  to  avoid  sending 
unwanted SMS messages in case of interference on the input.  
Temperature regulators are set up so that the OUTPUT Y5 is regulated by temperature 
sensor on INPUT A3 and OUTPUT Y6 from the temperature sensor on INPUT A4. 
 

6.2

 

Configuration using PC via USB 

The configuration (parameter setting) can be done using program 

SeaConfigurator

For connection to PC device has micro USB connector. 
 
E.g. 

GSM

 rele

5

 can be set to inform of the 230V AC power failure or restoration via SMS 

or by ringing. 
 

6.3

 

Change of configuration via SMS 

Some parameters of 

GSM

 rele

5

 can be configured via SMS: 

List of configuration SMS commands: 

 
 
Parameters  which  can  be  changed/set  via  SMS  are  marked  in 

SeaConfigurator 

in

 

yellow field

 

with symbol of SMS (picture below).By 

clicking 

on symbol window with hint 

will appear. 
 

LED 

COLOR 

Meaning 

Off 

On 

Blink 1 per 3s 

1:1 

PWR 

green 

device is off 

powered 

from  
230 V AC 

powered from 

backup 
battery 

ERR 

red 

no error 

error 

GSM 

blue 

No GSM 

signal 

registered 

Searching 

GSM net 

X1 

X2 

green 

Input is not 

activated 

Input is 

activated 

 

A3 
A4 

 

green 

Y5 
Y6 

yellow 

Output is 

disconnected 

Output is 

connected 

Command 

Parameter 

Meaning 

!FACTORY 

All parameters are setup to factory default. 
E.g. Reset to factory default in 

GSM

 rele

5

 (all custom 

configuration will be deleted.). 

1234 !FACTORY 

USER ADD 

Phone 

number 

 Create new user with specified phone number. If phone 

number is already in the list an error is indicated. If 
phone number already exists and user is “disabled”, User 
is enabled and no error is indicated. 

E.g. 1234 USER ADD +420123456789 

USER DIS 

Phone 

number 

A “disabled” flag for the user is set. If and user is not in 

the list an error is indicated. 

  E.g. Disable user with phone 420123456789    

from controlling device by ringing. 

 
  E.g. 1234 USER DIS +420123456789 

USER 
CHANGE 

Phone 

number 

 Changes phone number on different one. If fist phone 

number isn´t there or second one is already int the list 
an error is indicated. 

 E.g. Change user´s phone number from +420111111111 

to +420222222222 

 1234 USER                  

42011420222222222 

CODE ADD 

Password 

New user with specified password is added (password 

max. 20 digits).  If the password already exists an error 
is indicated.  If the password already exists and the user 
is disabled, the user is activated and no error is 
indicated. 

 
  E.g. Add new user with password 9876 
  1234 CODE ADD 9876  

CODE DIS 

Password 

A “disabled” flag for the code is set. If the user is not in 

the list an error is indicated. 

 
  E.g. Disable user with password 9876 from controlling    

device. 

 1234 CODE DIS 9876 

CODE 
CHANGE 

Password 

The first password in the list is replaced by the second 

password. If the first password does not exist in the list 
or the second is already in the list an error is indicated. 

 
  E.g. Change password from 1234 to 9876 
  1234 CODE CHANGE 1234 9876 

X1 !DIS 

!DIS 
!ENA 

 Disable/enable changes from input/output.  
 (Typical use is when error on input is occurred, on which 

GSM

 rele

5

 reacts by sending big amount of SMS 

messages.) 

 
 E.g.  

 1234 X1 !DIS

 … disables changes from input X1 

 1234 X2 !ENA

 … enables changes from input X2 

REGISTER 

number 

 Registration of sender of SMS messages as authorized 

person who can change settings of 

GSM

 rele

5

 

via GPRS 

connection. 

 Identification number has to match with number 

allocated from 

SeaConfigurator

 
 E.g. 
 1234 REGISTER 987654 

Summary of Contents for GSM-R5-DIN

Page 1: ...a confirmation SMS message on performing the operation The password 1234 can be changed later in configuration The GSM rele5 reacts on the SMS text message from any telephone as long as the access pa...

Page 2: ...king on symbol window with hint will appear LED COLOR Meaning Off On Blink 1 per 3s 1 1 PWR green device is off powered from 230 V AC powered from backup battery ERR red no error error GSM blue No GSM...

Page 3: ...ature regulation of OUTPUT Y6 will be set to 5 C Using multiple commands in one SMS message can look like this 1234 Y5 OFF Y6 REG 25 switch off output Y5 and sets temperature regulation on output Y6 t...

Page 4: ...ed by the best software engineers in SEA and was carefully tested both in SEA and also by SEA customers using GSM applications products made in SEA In spite of making all possible to get error free so...

Page 5: ...Y5 ON heat up to 22 C a 1234 Y5 OFF turn off heater If temperature drops below 5 C Output Y5 will be switched on and regulates to nonfreezing temperature If you have enabled heating to freezing tempe...

Page 6: ...to 25 C 1234 Y6 OFF Y5 TEPL 25 thermoregulator is disabled Regulation to 22 C 1234 Y6 ON Y5 OFF thermoregulator is set to 22 C Regulation to 7 C 1234 TEPL 7 thermoregulator is disabled 10 3 Digital i...

Page 7: ...le operator for help if necessary Check credit on a pre paid SIM card Ask your mobile operator for help if necessary Test the SIM card in your mobile phone The mobile phone should show the signal leve...

Reviews: