switched off, after pressing the button Y5 the output will be switched on and after next
pressing the output will be switched off again.
5.3
LED Diodes
The front panel of
GSM
rele
5
contains indication LED diodes
PWR
,
ERR
,
GSM
a LED
diodes for indication inputs (X1, X2, A3, A4) and outputs (Y5, Y6).:
5.4
Backup battery
GSM
rele
5
is equipped with backup 3.7 V Li-POL battery which enables to operate the
GSM
rele
5
for several hours in normal mode in case of a 230 V
AC
power failure (the
battery life time depends on mode of usage). During the battery supply mode the
GSM
rele
5
the
LED PWR
blinks at an interval of 1 for 3 seconds.
In case of failure of the main power supply, the device can send an SMS message.
The settings are made in
SeaConfigurator
– the power supply is listed on the Digital
inputs tab under the name PWW.
5.5
External antenna connector
GSM
rele
5
is supplied with an external antenna GSM-ANT05S with 2,5dB gain. It is not
recommended to put this type of antenna on metal surface (the signal quality will
degrade). If a
GSM
rele
5
is used in area with a low GSM signal, it’s possible to use
another type of the antenna with higher gain. See other antennas on
www.seapraha.cz
.
6.
Configuration
Configuration of the
GSM
rele
5
can be made in several ways.
6.1
Default Factory Configuration
When outputs Y5 or Y6 are switched on/off, the
GSM
rele
5
sends an SMS message to
the main user (to the telephone number from which it received the first valid command).
The input signal must be stable for certain time (approx. 1 sec) to avoid sending
unwanted SMS messages in case of interference on the input.
Temperature regulators are set up so that the OUTPUT Y5 is regulated by temperature
sensor on INPUT A3 and OUTPUT Y6 from the temperature sensor on INPUT A4.
6.2
Configuration using PC via USB
The configuration (parameter setting) can be done using program
SeaConfigurator
.
For connection to PC device has micro USB connector.
E.g.
GSM
rele
5
can be set to inform of the 230V AC power failure or restoration via SMS
or by ringing.
6.3
Change of configuration via SMS
Some parameters of
GSM
rele
5
can be configured via SMS:
List of configuration SMS commands:
Parameters which can be changed/set via SMS are marked in
SeaConfigurator
in
yellow field
with symbol of SMS (picture below).By
clicking
on symbol window with hint
will appear.
LED
COLOR
Meaning
Off
On
Blink 1 per 3s
1:1
PWR
green
device is off
powered
from
230 V AC
powered from
backup
battery
-
ERR
red
no error
error
-
-
GSM
blue
No GSM
signal
-
registered
Searching
GSM net
X1
X2
green
Input is not
activated
Input is
activated
-
-
A3
A4
green
-
-
-
-
Y5
Y6
yellow
Output is
disconnected
Output is
connected
-
-
Command
Parameter
Meaning
!FACTORY
-
All parameters are setup to factory default.
E.g. Reset to factory default in
GSM
rele
5
(all custom
configuration will be deleted.).
1234 !FACTORY
USER ADD
Phone
number
Create new user with specified phone number. If phone
number is already in the list an error is indicated. If
phone number already exists and user is “disabled”, User
is enabled and no error is indicated.
E.g. 1234 USER ADD +420123456789
USER DIS
Phone
number
A “disabled” flag for the user is set. If and user is not in
the list an error is indicated.
E.g. Disable user with phone 420123456789
from controlling device by ringing.
E.g. 1234 USER DIS +420123456789
USER
CHANGE
Phone
number
Changes phone number on different one. If fist phone
number isn´t there or second one is already int the list
an error is indicated.
E.g. Change user´s phone number from +420111111111
to +420222222222
1234 USER
42011420222222222
CODE ADD
Password
New user with specified password is added (password
max. 20 digits). If the password already exists an error
is indicated. If the password already exists and the user
is disabled, the user is activated and no error is
indicated.
E.g. Add new user with password 9876
1234 CODE ADD 9876
CODE DIS
Password
A “disabled” flag for the code is set. If the user is not in
the list an error is indicated.
E.g. Disable user with password 9876 from controlling
device.
1234 CODE DIS 9876
CODE
CHANGE
Password
The first password in the list is replaced by the second
password. If the first password does not exist in the list
or the second is already in the list an error is indicated.
E.g. Change password from 1234 to 9876
1234 CODE CHANGE 1234 9876
X1 !DIS
!DIS
!ENA
Disable/enable changes from input/output.
(Typical use is when error on input is occurred, on which
GSM
rele
5
reacts by sending big amount of SMS
messages.)
E.g.
1234 X1 !DIS
… disables changes from input X1
1234 X2 !ENA
… enables changes from input X2
REGISTER
number
Registration of sender of SMS messages as authorized
person who can change settings of
GSM
rele
5
via GPRS
connection.
Identification number has to match with number
allocated from
SeaConfigurator
.
E.g.
1234 REGISTER 987654