ESUN  PLUS  BOOST  has  got  a  buck-boost  charge  circuit  with  control  of  the 

maximum power  point  of  the  PV  module  (MPPT).  The  main  difference 

between  this  controller  and  other  types  with  buck  circuit  is  that  ESUN 

PLUS BOOST is able to allow the working of the PV module at a voltage than 

can be either higher or lower than that of battery; this allows, for example, to 

use a PV module with open circuit voltage of 10V for the charge of batteries 

both at 12V and 24V. PV module voltage during the working of MPPT circuit 

goes  from  5V  to  40V  with  both  12V  and  24V  batteries. 

ESUN  PLUS  BOOST  is  a  complete  solution  for  the  realization  of  off-grid  PV 

systems,  to  power  supply  road  signs  systems,  lighting  systems,  small  low 

voltage  systems  and 

for 

the 

charge 

of 

batteries 

inside 

caravans  and  boats.  The  several  programs  of  load  management, 

selectable  by  the  user,  make ESUN  PLUS  BOOST  the  proper  solution  in 

several  applications;  i.e.  to  power  supply  video  cameras  that  have  to 

work  only  during  the  day,  or  to  power  supply flashing  systems/road signs 

that  have  to  work  only  during  night  or  to  power supply  lighting  systems 

that have  to  work  only  for  a  certain  number  of  hours during  night.  ESUN 

PLUS BOOST  detects  the  day/night  status  according  to  the  PV module’s 

voltage;  therefore,  it  is  not  necessary  to  connect  further  sensors  to  the 

controller.  A  wide  display  shows  the  working  status  of  the  charge 

controller either through simple and intuitive icons or displaying the values 

of charge  current, battery  voltage,  energy  produced  by  the  PV  module, 

load current and energy consumed by the load. 

 MPPT charge with buck-boost 

circuit 

Max PV module power: 

120W for 12V battery 

220W for 24V battery 

Integrated blocking diode 

For sealed, GEL or flooded lead 

acid batteries and and lithium-

ion batteries  

Temperature compensated 

Charge voltage 

Auto-detect of battery voltage: 

12V / 24V 

18 programs for load 

management 

LCD for user interface 

IP20 metal box 

Low battery protection

Over temperature protection

Protection for battery polarity

inversion

Overload protection on output

Summary of Contents for E-SUN PLUS BOOST

Page 1: ...E SUN PLUS BOOST SOLAR MPPT CHARGE CONTROLLER Manuale utente User manual Manuel de l utilisateur Manual del usuario Benutzerhandbuch IT DE ES EN FR 67410218 Rev 00 08 22 ...

Page 2: ...ower supply video cameras that have to work only during the day or to power supply flashing systems road signs that have to work only during night or to power supply lighting systems that have to work only for a certain number of hours during night ESUN PLUS BOOST detects the day night status according to the PV module s voltage therefore it is not necessary to connect further sensors to the contr...

Page 3: ...y to place a fuse of adequate current on the battery cable as close as possible to the positive battery terminal Warranty The defective product must be returned to SEA S p A for assistance at the expense of the customer along with a copy of the sales invoice both for repairing and guaranteed replacement The costs of re installation of the material will be borne by the customer Warranty does not co...

Page 4: ...pts Vpan and Ipan respectively voltage and current of the PV module so to search the condition in which the power that is given by the PV module is maximum thus realizing the MPPT Maximum Power Point Tracking In addition it manages the battery charge by reducing the current sent towards the battery when the battery Vbatt exceeds its charge voltage Veoc 2 Circuit for load control it turns on off th...

Page 5: ...SUN PLUS BOOST recognizes automatically the battery nominal voltage 12V or 24V and it adapts consequently its threshworkingolds The user must configure the kind of battery in use to adequate the right charge voltage Veoc You have to set SEAL configuration if you use VRLA or GEL sealed batteries while you have to choose FLOOD configuration if you use flooded lead acid batteries If you use lithium i...

Page 6: ...8 8V 24V and even with a good lighting of the PV module you have low charge currents since the controller limits such current so to avoid the battery overcharge button PV module voltage Vpan button It displays the power in watt actually delivered by the PV module button It displays the counter of energy that is delivered by the PV module in KWh It is possible to reset this measure pressing simulta...

Page 7: ...s but the charge voltage is equal for every temperature measured Charge voltage relating to each one of the programs are indicated in the following Pic 3 Tab 4 and must be chosen in accordance with the battery manufacturer indications Page change Low Battery voltage configuration page It sets the intervention voltage of Low Battery protection load detachment in case of low battery When pressing th...

Page 8: ...r when internal temperature of ESUN PLUS BOOST exceeds 80 C and deactivates the charge You exit automatically from this protection when the internal temperature goes below the threshold of 50 C note the internal temperature of the charge controller is not displayed on the LCD If you see often this protection we advise to place the device in a cooler place Overload protection occurred The load curr...

Page 9: ...ure C End charge voltage Volt SEAL FLOOD End charge voltage according to temperature 24V system 27 0 27 5 28 0 28 5 29 0 29 5 30 0 30 5 31 0 31 5 32 0 10 5 0 5 10 15 20 25 30 35 40 45 50 55 60 Temperature C End charge voltage Volt SEAL FLOOD Pic 3 Compensation curve of Veoc charge voltage according to battery temperature Dimensions Pic 4 Dimensions ...

Page 10: ...b 10 8V 11 4V default 12 2V 21 6V 22 8V default 24 4V Output voltage from low battery settable Velb 12 4V 13 8V default 13 8V 24 8V 27 6V default 27 6V Solar modules threshold voltage for day detection settable Vday 12 4V 13 8V default 13 8V 24 8V 27 6V default 27 6V Solar modules threshold voltage for night detection Vnight Vday 1 3V Vnight 0 6V 8 3V 0 6V 8 3V Float phase voltage settable Vflt 13...

Page 11: ...__________________ ________________________________________________________ ________________________________________________________ ________________________________________________________ ________________________________________________________ ________________________________________________________ ________________________________________________________ _______________________________________...

Page 12: ......

Reviews: