background image

Fig. 23

Fig. 24

Fig. 25

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

CORONA S/RP

67410622

Rev 00 - 02/2012

Fig. 27

Fig. 26

F1

F2

F1= 6.3 AT
F2= 3.15 AT

Base 
for
pulling

Bend link

lever

Base for
pulling

Link lever

7. ELECTRONIC CONTROL UNIT

ENGLISH

17

1.

 Close the door and fix the base for pulling   at the center on the top of the door (Fig. 23).

2. 

Release the

 

 sleigh (Fig.24).

Place the sliding block (sleigh) near the door. Connect the base for pulling, the bend link lever, the link lever and the sleigh (Fig.25).

- Install the the manual release at a height of max. 1.8m
- The warning boards   against entrapment should be permanently fixed in a known place   or near any fixed control.
- The notice concerning the manual release should be permanently fixed next to said release.

After installation, make sure that the mechanism is properly adjusted and that the drive reverses when the door touches   a 50 mm 
high object placed on the floor. 

6. CONNECTION OF THE  DOOR WITH THE SLIDING BLOCK (SLEIGH)

 

 FOR CORONA RP 

For accessing the electronic unit and execute all desired settings, unscrew the two fixing screws (Fig. 26) and open the case as 
shown in Fig. 27.

Sleigh

Summary of Contents for CORONA 110

Page 1: ...ushing safety is assured by an electronic system which set during installation stops the door in opening and reverses during closing phase Corona S RP irreversibility avoids the use of electro locks while guaranteeing maximum security during forcing attempts A Manual Release ensures door operation also in case of power failure ENGLISH MAIN PARTS OF THE CORONA S OPERATOR MAX DOOR MAX DOOR DIMENSION...

Page 2: ...ed screws B into the holes of the aluminium profiles Fig 4 Connect the two ends of the chain using the connecting link and the two provided screws Fig 5 Make sure that the chain has been correctly mounted on the pinion of the Corona S body Fig 7 A Place the guide on the stop of the Corona S body and fix it with the special bracket Fig 7 B Mount the front fixation support on the other end of the gu...

Page 3: ... making sure that it s placed iat the centre of the door Fix the anchor bracket to the door frame or if necessary on the wall using rivets or bolts Fig 8 Lift the Corona S and fix it to the ceiling with the special brackets keeping a maximum distance of 400 mm from the ceiling and making sure that the operator is in a perfectly horizontal position Fig 9 Release the Corona S operator and drag the d...

Page 4: ...m Min 90 Fig 10 Fig 12 Fig 13 Fig 14 1 2 3 up to 2 7 H x 3 L m up to 2 7 H x 3 L m CORONA60 CORONA60 up to 2 7 H x 4 L m up to 2 7 H x 4 L m CORONA110 CORONA110 OPERATORS FOR COUNTERBALANCED OVERHEAD DOORS MAX DOOR MAX DOOR DIMENSIONS DIMENSIONS ENGLISH Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 Fig 11 CORONA S RP 67410622 Rev 00 02 2012 14 We reco...

Page 5: ...e Release knob Fixing bracket U shaped bracket To adjust the door closing as precise as possible release the bolts on the curved rod and adjust the run on the two holes Fig 15 CONNECTION OF THE OPERATOR CORONARPWITH THE GUIDE TRACK Before installing the operator remove all unnecessary ropes or chain and disable any equipment such as locks not needed for powdered operation Before installing the ope...

Page 6: ... 18 Fig 19 Fig 20 Fig 21 Fig 22 67410622 Rev 00 02 2012 Centre line Wall Door ENGLISH 16 5 INSTALLATION OF THE GUIDE ON THE WALL AND ON THE CEILING FOR CORONA RP Guide Wood Thikness 25mm junction in the space within door and guide Sleigh After having fixed the operator to the hanging firmware remove the wood ...

Page 7: ...e bend link lever the link lever and the sleigh Fig 25 Install the the manual release at a height of max 1 8m The warning boards against entrapment should be permanently fixed in a known place or near any fixed control The notice concerning the manual release should be permanently fixed next to said release After installation make sure that the mechanism is properly adjusted and that the drive rev...

Page 8: ...ways run mains carrying cables in separate ducts to low voltage control cables to prevent mains interference INTENDED USE The CORONAS RPoperator has been designed to be solely used for the automation of sectional doors and balancing doors SPARE PARTS To obtain spare parts contact SEAs r l Zona Ind le 64020 S ATTO Teramo Italia SAFETYAND ENVIRONMENTALCOMPATIBILITY Don t waste product packing materi...

Page 9: ...STEM FOR CORONA S To release the operator work as follows Turn the knob and open the door manually Fig 30 Notice This release system allows the external releasing of the door Fig 29 ENGLISH Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 19 Fig 30 To the attention of users and technicians CORONA S RP 67410622 Rev 00 02 2012 ...