Fig. 23
Fig. 24
Fig. 25
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
CORONA S/RP
67410622
Rev 00 - 02/2012
Fig. 27
Fig. 26
F1
F2
F1= 6.3 AT
F2= 3.15 AT
Base
for
pulling
Bend link
lever
Base for
pulling
Link lever
7. ELECTRONIC CONTROL UNIT
ENGLISH
17
1.
Close the door and fix the base for pulling at the center on the top of the door (Fig. 23).
2.
Release the
sleigh (Fig.24).
Place the sliding block (sleigh) near the door. Connect the base for pulling, the bend link lever, the link lever and the sleigh (Fig.25).
- Install the the manual release at a height of max. 1.8m
- The warning boards against entrapment should be permanently fixed in a known place or near any fixed control.
- The notice concerning the manual release should be permanently fixed next to said release.
After installation, make sure that the mechanism is properly adjusted and that the drive reverses when the door touches a 50 mm
high object placed on the floor.
6. CONNECTION OF THE DOOR WITH THE SLIDING BLOCK (SLEIGH)
FOR CORONA RP
For accessing the electronic unit and execute all desired settings, unscrew the two fixing screws (Fig. 26) and open the case as
shown in Fig. 27.
Sleigh