background image

4. INSTALLATION OF THE OPERATOR

4.1.

Insert manually the operator

 

into the

 

carrying box (Fig. 15) 

also insert the splined shaft of the operator into the splined bush 
of the box and fix the operator with the special screws as in Fig. 
17.

4.2.

Carry out the electrical connections to the control unit as 

described in the instructions supplied with SEA control unit.

After ending all the operations in the installation of the above 
mentioned carrying box, of the gate and the operator, try to do 
some moves slowly by hand verifying that there are not irregular 
frictions and that the movement is uniform for the whole range.

Notice:

 To do this last operation, release the operator as 

described in the next paragraph. 

5. MOTOR RELEASE SYSTEM

5.1. To release act as follows:

-Turn the release screw with the screwdirver about 180° ca. in 
anti- clockwise direction (Fig. 18).

     

5.2. To stop again act as follows:

-Turn the release screw with the screwdriver into clockwise 
direction until it stops.

ENGLISH

6. MOUNTING OF THE RELEASE

For the Compact there are foreseen two types of release:   
RELEASE (with personalised key) and RELEASE PLUS 
(with DIN key).

RELEASE

6.1.

Grease the hinge (A) and mount the release system under 

the leaf device using the 4 furnished screws (Fig. 19) 

RELEASE PLUS

6.2.

Grease the hinge (A) and mount the release system under 

the leaf device using the 5 furnished screws (Fig. 20).

67410850 

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

N.B.

: It is advisable to weld the crank with the crank shaft after 

having also installed the Compact, to use the whole available run 
and the point of beginning of the desired slowdown (version with 
hydraulic slowdown). 
Before welding, make sure that one of the level of the crank shaft 
corresponds with a side of the crank (see fig.16 and 17) to 
guarantee the maximum angle with the mechanical stops Kit.

N.B.

: If the Compact is not installed immediately but in a second 

time, it is recommended to weld the crank shaft and the crank 
during the installation of the Compact.  

REV 04 - 01/2010

13

Fig. 15

Fig. 17

1

2

Fig. 16

Fig. 19

A

Release

Fig. 18

Lock

Release

Summary of Contents for Compact 400

Page 1: ... conjunction with a separate electrical locking device to ensure keeping in closing On the operators with hydraulic slow down it is present only during the last 15 of rotation The system comes with a release which allows the manual opening of the leaves in case of power failure FITTING AND CONNECTION INSTRUCTIONS In case of operator with hydraulic slow down ENGLISH GRAPHIC FOR THE USE OF COMPACT 4...

Page 2: ...ing box must have the approximate dimensions mentioned in Fig 4 For a correct placing it is obbligatory to follow closely the quote of 55 mm which corresponds to the minimum distance of the rotation axis from the pillar 2 2 Inside the excavated pit you have to plan rain water drainage a water waste pipe in flexible plastic of about 40 mm of diameter to put inside the provided hole of the box befor...

Page 3: ...voiding the welding next to the threaded holes furthermore it is necessary to respect the perpendicularity to the axe of rotation Fig 10 3 3 Be careful not to place the leaf outside the axis Fig 12 and 13 but make sure the shaft corresponds to the hinge rotation axis remembering that the minimum distance from the pillar is 55 mm Fig 14 67410850 Sistemi Elettronici di Apertura Porte e Cancelli Inte...

Page 4: ...until it stops ENGLISH 6 MOUNTING OF THE RELEASE For the Compact there are foreseen two types of release RELEASE with personalised key and RELEASE PLUS with DIN key RELEASE 6 1 Grease the hinge A and mount the release system under the leaf device using the 4 furnished screws Fig 19 RELEASE PLUS 6 2 Grease the hinge A and mount the release system under the leaf device using the 5 furnished screws F...

Page 5: ...lied with SEAcontrol unit ENGLISH RELEASE PLUS 7 3 To release act as follows Insert the enclosed key into the keyhole and turn it about 90 in clockwise direction Fig 22 Pull the key against the external of the release making come out the handle of the lock until it reaches the stop Fig 23 Move the leaf and make return the handle of the release in its original position and extract the key 7 4 To st...

Page 6: ...he leaf slowdown in opening and in closing through the braking adjusting screw Fig 33 10 2 To regulate slowdown operate as follow Loosen the blocking screw of braking regulation Act on the adjusting screw clockwise to have a higher braking and a speed decrease Act on the adjusting screw anti clockwise to have a lower braking and a speed increase After the regulation fix the blocking screw of braki...

Page 7: ... deemed responsible for any damage or accident caused by product breaking being damages or accidents due to a failure to comply with the instructions herein The guarantee will be void and the manufacturer responsibility according to Machine Law will be nullified if SEASrl original spare parts are not being used This is a quotation from the GENERAL DIRECTIONS that the installer must read carefully ...

Page 8: ...bles to prevent mains interference INTENDED USE Compact 400 and Compact 800 undergrounded operators have been designed to be used only for the automation of swing gates SPARE PARTS To obtain spare parts contact SEAs r l Zona Ind le 64020 S ATTO Teramo Italia SAFETYAND ENVIRONMENTALCOMPATIBILITY Don t waste product packing materials and or circuits When being transported this product must be proper...

Reviews: