WARNING:

 SEA recommends to the end user to release the operator only after having switched off the electric power.

Always contact a professional installer in case of not correct working of the operator.

LO

C

K

UNLOCK

LOCK

Up

Down

Fig. 23

MANUAL RELEASE SYSTEM

WARNING: 

Always switch off the main power (110V or 230V) before servicing the operator. 

All the above described operations MUST be made exclusively by an authorized installer.

1) Check the solidity and the stability of the gate, especially the points of   support and/or rotation of 
the gate (pivots).

2)

Check the oil level of the hydraulic/in oil bath operators (cap on rear cover of the Mini Tank)

3)

Change the hydraulic oil with the one recommended from the head company

4)

Check the release function

5)

Check the by-pass valves function

6)

Check and lubricate the fixing pins

7)

Check the integrity of the connection cables

8)

Check the function and the positive stops condition in opening and closing (where there is 

present a mechanical positive stop accessory)

9)

Check the good status of all parts   which are forced (rear bracket, oscillating bracket and front 

bracket).
10) Check the operating of all accessories, especially the function of all safety devices and of the 

Safety Gate.

11) 

After having executed the periodical maintenance operations it is necessary to repeat the 

test and the putting in service of the automation

PERIODICAL MAINTENANCE  

Annual

Annual

4 years

Annual

Annual

Annual

Annual

Annual

Annual

Annual

Annual

MINI TANK

MARK TANK

Automazione Porte 
e Cancelli

REV 01 - 07/2006

Summary of Contents for 620660

Page 1: ...MANUAL and Security Information SEA S r l Zona Ind S Atto 64020 TERAMO Italy Tel 39 0861 588341 Fax 39 0861 588344 e mail seacom seateam com WEB SITE www seateam com 13 HYDRAULIC OPERATOR FOR SWING G...

Page 2: ...slow down in opening and closing with control board GATE 2 For the European laws and directives actually in force it is strongly recommended to use the Safety Gate device for the reading of the gate p...

Page 3: ...in long Breather screw Release key Plastic frame anti vibration big Plastic frame anti vibration small Valve cover Front bracket r M a k a n k v e s i o n T r Shaft Cover End cover By pass valves adju...

Page 4: ...tion Outward installation 16 1 Libra operator 2 Mechanical stop 3 Gate 2 control board 4 Warning lamp 5 Photocell tx 6 Differential switch 16A 0 03A 7 Photocell rx 8 Key switch start stop 9 Antenna 10...

Page 5: ...45 145 150 155 160 170 180 150 160 165 175 180 180 90 90 80 80 70 65 95 90 95 90 90 90 115 150 110 145 105 130 125 95 110 95 105 100 85 90 75 65 50 50 55 55 70 70 75 90 90 95 95 100 105 110 120 130 11...

Page 6: ...llating bracket 1 risks the possible braking of it INSTALLATION OF THE OSCILLATING REAR BRACKET 18 Fig 8 Fig 9 Adjustable rear bracket with screws Accessory on demand INSTALLATION OF REAR BRACKET Acco...

Page 7: ...he front bracket Fig 13 Attention avoid the welding of the front bracket to the shaft of the hydraulic operator already attached the welding scraps daps could ruin the chromium plating of the shaft Fi...

Page 8: ...ush A into the shaft at this point couple the shaft to the front bracket To adjust the positive stops in opening act on disk 1 and in closing act on disk 2 Attention The mounting of the mechanical pos...

Page 9: ...erior of 15 KgF INSTALLATION OF THE CHROME PLATED SHAFT COVER Fig 22 Up Down Up Grey Yellow Fig 19 Fig 20 Fig 21 Grey s u s e r r e p in g n o i t p a e r n e i n p g O Yellow Acting on the by pas val...

Page 10: ...ic oil with the one recommended from the head company 4 Check the release function 5 Check the by pass valves function 6 Check and lubricate the fixing pins 7 Check the integrity of the connection cab...

Page 11: ...nullified if original spare parts are not being used Packaging materials such as plastic bags foam polystyrene nails etc must be kept out of children s reach as dangers may arise in fig 38 Re Laws in...

Page 12: ...iniTank and Mark Tank operators are been designed to be solely used for the automation of swing gates SPARE PARTS To obtain spare parts contact SEAs r l Zona Ind le 64020 S ATTO Teramo Italia SAFETYAN...

Reviews: