USER 1 - 24V
Allows to regulate and to visualize
the sensitivity of the anti-sqeezing
for single opening direction With
value 100% the gate in presence of
obstacle will reverse the movement
after 5 seconds.
.
Screen 12
Balanced edge on/off ( In ON it is necessary to insert in series to the edge
contact a 8K2 Ohm resistance)
24V aux During cycle/in opening/in closing/in Pause/Always
N°8
Mot. rev. ON/OFF Allows to exchange contemporarily the limit switch
and the motor rotation direction without disconnecting the
wires
N°9
Start on pause ON/OFF If on ON with autom. Clos. on ON a start
impulse provoques the immediate re-closing of the autom.
N°10
Autom. clos. ON/OFF If on ON at the end of the set pause
the gate re-closes automatically
18
Normal
:
1 Flash/s in opening
2 Flash/s in closing
On in pause
Control lamp
: the alarm signals
remain until they are eliminated
Continuous
: flashes always also
when gate is not in movement
Allows to decide when having power
supplied the exit 24V Aux.
Note:
After this operation it is
necessary to switch off the power
supply of the motors and to repeat
the selflearning of the times. If the
motor is not syncronized with the
limit switch, during selflearning the
automation stops on the first limit
switch it recognizes without
completing the selflearning of the
times. In that case it will be
necessary to switch off the power
supply again, to manually exchange
the wires of the motor and to repeat
the selflearning.
PROGRAMMER JOLLY PARAMETERS ADJUSTMENT
NOTE
: For the respect of the valid European ruels on the safety of the electric gates, it is recommended to not adjust the
parameters
torque Max 1
and
torque Max 2
on the value 100%.
Screen 10
Accelerat. [0÷100]% (inclination of the ramp of acceleration)
Decelerat. [0÷100]% (inclination of the ramp of acceleration)
Pedestrian op. [30,50,100]% (percentage pedestrian opening)
It allows to regulate the duration of
the acceleration of the motors on
the start If on 100% the gate will
immediately depart at the max.
adjusted speed
It allows to regulate the duration of
the deceleration of the motor at the
end of opening and closing. If on 0%
the gate won't effect the phase of
deceleration.
Screen 11
Torque op. M1 [10÷100]% (max. current of the motors)
Torque clo. M1 [10÷100]% (max. current of the motors)
Anti-intrusion on/off (in ON it implicates the presence of a contact N.C.
On the limit switch that, if freed, forces the motors in closing
Pre- flashing on/off (activation of the pre-flashing)
Autotest photo. on/off (activates autotest photocell)
Max cycle 0÷100000 (indicates the number of cycles after which it is
necessary to follow up the maintenance)
Warning lamp Normal/Control/Continuous
Screen 13
Screen 14
Photo/Timer ON/OFF On ON the PHOTO entry becomes TIMER
Clos. Photo ON/OFF On ON if the photocell is occupied the gate
recloses interrupting the pause
Ped/Timer ON/OFF On ON the PED entry becomes TIMER
Screen 15
Screen 16
List of events Shows the last 10 events on the control unit
Diagnostic 10 last events
Reverse stroke on/off (Disabled)
Posit. recover 0% 100%
Allows to optimize the point of
slowdown beginning in case of
inversion of the motion and in
function of the weight of the gate
Foto closing/opening/stop/park
For the functions Fotoopen,
Fotostop, Fotopark, see page 9.