8.13
S
ECTION
8 • R
EQUIRED
I
NSPECTION
, S
ERVICE
AND
M
AINTENANCE
44 Sedan Bridge (
455 sedan bridge
)
Q
UICK
R
EFERENCE
C
HECKLIST
(
CONT
’
D
)
Do not run the generator or engines in an
enclosed area, such as a closed boat house, as
there is the possibility of buildup and inhaling of
carbon monoxide.
!
WARNING
G. O
PERATING
THE
G
ENERATOR
S
TARTING
THE
G
ENERATOR
1. Generator Seacock ....................................................... Open
2. Bilge Blowers ................................................................ Run for at least 4 minutes and any time the generator is running
3. Depress PREHEAT/ON ................................................ Preheat time should not exceed 30 seconds
4. Depress START/RUN Switch ....................................... Depress until generator starts
5. When the Generator Starts ........................................... Release the START switch only continue holding PREHEAT/
ON for a few seconds)
6. Load The Generator ..................................................... Turn ON the generator main breaker on the Main
Distribution Panel. Turn AC breakers ON
S
TOPPING
THE
G
ENERATOR
1. Breakers ........................................................................ Turn AC breakers OFF. Turn OFF the generator main breaker
on the Main Distribution Panel
2. Generator ...................................................................... Let it run a few minutes to cool down
3. STOP Switch ................................................................. Depress to stop the generator set
Summary of Contents for 44 Sedan Bridge
Page 2: ...44 Sedan Bridge 455 Sedan Bridge ii...
Page 32: ...44 Sedan Bridge 455 Sedan Bridge 1 22 This page intentionally left blank...
Page 102: ...44 Sedan Bridge 455 Sedan Bridge 5 6 SECTION 5 FUEL SYSTEM THIS PAGE LEFT INTENTIONALLY BLANK...
Page 218: ...44 Sedan Bridge 455 Sedan Bridge INDEX THIS PAGE LEFT INTENTIONALLY BLANK...