SPECIFICATION TABLE

SEA-FIRE “FD” SERIES AUTOMATIC FIRE EXTINGUISHERS

4B/360, 4BW/500 CYLINDERS

AREA OF

MINIMUM

MAXIMUM

DIAMETER X

FD MODEL

PROTECTION

FM-200

®

 FM-200

®

HEIGHT

MAN/

CU.FT.

CU.M.

AUTO

AUTO

RANGE

RANGE

LBS

KG

LBS

KG

IN

MM

FD150A

FD150M

126-150

3.5-4.2

5.4

2.4

6.5

2.9

5.1x17

130x432

FD175A

FD175M

151-175

4.2-5.0

6.5

2.9

7.6

3.4

5.1x17

130x432

FD200A

FD200M

176-200

5.0-5.7

7.6

3.4

8.7

3.9

5.1x17

130x432

FD225A

FD225M

201-225

5.7-6.4

8.7

3.9

9.7

4.4

6.1x17

160x432

FD250A

FD250M

226-250

6.4-7.1

9.7

4.4

10.8

4.9

6.1x17

160x432

FD275A

FD275M

251-275

7.1-7.8

10.8

4.9

11.9

5.4

6.1x17

160x432

FD300A

FD300M

276-300

7.8-8.5

11.9

54

13.0

5.9

6.1x17

160x432

FD325A

FD325M

301-325

8,2-9.2

13.0

5.9

14.0

6.4

6.1x17

160x432

FD350A

FD350M

326-350

9.2-9.9

14.0

6.4

15.2

6.9

6.1x17

160x432

FD400A

FD400M

351-400

9.9-11.3

15.2

6.9

17.3

7.8

7.1x18

180x457

FD450A

FD450M

401-450

11.3-12.7

17.3

7.8

19.5

8.8

7.1x18

180x457

FD500A

FD500M

451-500

12.7-14.2

19.5

8.8

21.7

9.8

7.1x18

180x457

FD550A

FD550M

501-550

14.2-15.6

21.7

9.8

23.8

10.8

7.1x18

180x457

FD600A

FD600M

551-600

15.6-17.0

23.8

10.8

26.0

11.8

8.1x22

206x559

FD650A

FD650M

601-650

17.0-18.4

26.0

11.8

28.1

12.7

8.1x22

206x559

FD700A

FD700M

651-700

18.4-19.8

28.1

12.7

30.3

13.7

8.1x22

206x559

FD750A

FD750M

701-750

19.8-21.2

30.3

13.7

32.5

14.7

8.1x22

206x559

FD800A

FD800M

751-800

21.2-22.7

32.5

14.7

34.6

15.7

8.1x33

206x838

FD850A

FD850M

801-850

22.7-24.1

34.6

15.7

36.8

16.7

8.1x33

206x838

FD900A

FD900M

851-900

24.1-25.5

36.8

16.7

39.0

17.7

8.1x33

206x838

FD950A

FD950M

901-950

25.5-26.9

39.0

17.7

41.1

18.6

8.1x33

206x838

FD1000A

FD1000M

950-1000

26.9-28.3

41.1

18.6

43.3

19.6

8.1x33

206x838

FD1050M

1001-1050

28.3-29.8

43.3

19.6

45.5

20.5

10x26

254x660

FD1100M

1051-1100

29.8-31.1

45.5

20.5

47.6

21.6

10x26

254x660

FD1150M

1101-1150

31.1-32.6

47.6

21.6

49.8

22.6

10x26

254x660

FD1200M

1151-1200

32.6-34.0

49.8

22.6

52.0

23.6

10x26

254x660

FD1250M

1201-1250

34.0-35.4

52.0

23.6

54.1

24.5

10x26

254x660

FD1300M

1251-1300

35.4-36.8

54.1

24.5

56.3

25.5

10x26

254x660

FD1350M

1301-1350

36.8-38.2

56.3

25.5

58.5

26.5

10x26

254x660

FD1400M

1351-1400

38.2-39.6

58.5

26.5

60.6

27.5

10x26

254x660

FD1450M

1401-1450

39.6-41.1

60.6

27.5

62.8

28.5

10x26

254x660

FD1500M

1451-1500

41.1-42.5

62.8

28.5

65.0

29.5

10x26

254x660

OPERATING TEMPERATURE RANGE:

20° TO 130°F (-7° TO 54°C) FD MODELS

DISCHARGE TEMPERATURE:

FD-150 thru FD-1500         175°F (79°C)

MODEL FD-150 thru FD-1000 APPROVED FOR VERTICAL OR HORIZONTAL MOUNTING

MODEL FD-1050 thru FD-1500 FOR VERTICAL MOUNTING ONLY

Cubic Feet = CU.FT.

Kilograms = KG

Cubic Meters = CU.M.

Inches = IN

Pounds = LBS

Millimeters = MM

V M
E O
R U O
T N N

I T L

C I Y
A N
L G

14

Step 5

Locate bracket in desired position (Vertical-Sensor Valve/Detector Head Up, or
Horizontal, Figure 2). Using the bracket as a template, mark and drill holes in bulkhead
and install bracket insuring that all bolts are thoroughly tight.

Figure 2

WARNING: When installing cylinder in horizontal position, the actuator (top of cylinder)
must NEVER be lower than the bottom of the cylinder or proper discharge of agent will not
occur (see Figure 2 above).

MODELS FD1100 THRU FD1500 MUST BE INSTALLED VERTICAL ONLY

Step 6    Carefully attach cylinder to bracket. Sensor valve/Detector head should point towards

engine or center of the compartment. Nameplate should be visible. Tighten bracket
straps so that the cylinder body is firmly and securely held in place by its’ bracket.

CABLE ASSEMBLY INSTALLATION

(for FG and FD systems with “M” designation - manual discharge capability:

Model SMAC-XX is required.)

CAUTION: TO PREVENT ACCIDENTAL DISCHARGE DURING CABLE INSTALLATION,
VERIFY THAT THE MANUAL DISCHARGE LEVER SAFETY PIN IS PROPERLY INSTALLED
(SEE FIGURE 6A OR 7C).

Step 1

Select the proper location.
a. Manual discharge release handles should never be installed in the protected

compartment.

b. Locate discharge handle at the helm station with full view and easy access by the

operator.

c. The area selected must be structurally secure and provide at least twelve (12)

inches (305mm) of clearance at the rear of the panel to facilitate cable hardware.

d. Do not install actuator cable in area where the possibility of physical abuse is likely.

Where practical, follow the same cable path as installed by boat manufacturer.

e. The cumulative number of bends in the cable run must never exceed 360 degrees.

This is equivalent to four (4) right (90°) angles. Use extreme care when bending
cable to avoid kinking. Never form a bend with a radius of less than twelve (12)
inches (305mm). Selection of the correct size Sea-Fire cable length will eliminate
cable coil.

Step 2    Mounting manual cable, faceplate, and release handle.

a. Using the manual discharge faceplate as a template (Figure 5) mark and drill a

13/32 inch (10.4mm) hole. Install the manual release cable adhering to the
guideline in Step 1 above.

b. Do not connect cable to the cylinder at this time.
c. Remove the protective backing from the faceplate. While aligning the holes, place

even pressure upon the faceplate. To insure a good bond, the temperature should
be in excess of 50°F (10°C).

7

Summary of Contents for FD1000A

Page 1: ...FIRE EXTINGUISHERS INSTALLATION INSTRUCTIONS OWNER S MANUAL THIS MANUAL IS AN INTEGRAL PART OF THE SYSTEM AND AS SUCH THE EXTINGUISHER MUST BE INSTALLED AND MAINTAINED ACCORDINGLY U S COAST GUARD APPROVED FM APPROVED No 162 029 237 0 READ AND COMPLY WITH THESE INSTRUCTIONS WARNINGS AND LIMITATIONS BEFORE INSTALLING SUITABLE FOR USE FG MODELS 0 F 18 C TO 130 F 54 C FD MODELS 20 F 7 C TO 130 F 54 C ...

Page 2: ... DISCLAIMER OF EXPRESSED AND IMPLIED WARRANTIES Metalcraft Sea Fire Marine Inc has taken reasonable care in preparing this document how ever since the use of this information and the conditions of use of the product are not within the control of Metalcraft Sea Fire Marine Inc it is the user s obligation to determine the con ditions of safe use of this product The information in this document is of...

Page 3: ...nd or heart irregularities arrhythmias Misuse of the products by deliberately inhaling high concentrations of this gas could cause death without warning Persons with preexisting cardiac or central nervous sys tem disorders may be more susceptible to effects of an overexposure Section 12 Ecological Information No ecological information is available Section 13 Disposal Considerations Dispose of wast...

Page 4: ...t the combustion reaction cannot sustain itself CAUTION IN CASE OF EXTINGUISHER DISCHARGE DO NOT RUSH TO OPEN THE PROTECTED COMPARTMENT LET THE EXTINGUISHING AGENT WORK FOR SEVERAL MINUTES HAVE A PORTABLE EXTINGUISHER AVAILABLEAND USE CARE WHEN OPENING THE COMPARTMENT AVOID BREATHING FIRE RELATED FUMES OR VAPOR NOTE It is important to retain the designed vapor concentration within the compartment ...

Page 5: ... 2 0 AMPS AT 28 VDC For applications requiring larger load capacities see optional equipment section in this manual or contact factory ENGINES AND POWERED VENTILATION BLOWERS DIESEL ENGINES Continued operation of diesel engine s and or powered ventilation units will deplete the extinguishing agent and may cause a fire re flash Diesel engine s must be automatically shutdown upon extinguisher discha...

Page 6: ...26 150 3 5 4 2 5 4 2 4 6 5 2 9 5 2x17 0 132x476 FD175A FD175M 151 175 4 2 5 0 6 5 2 9 7 6 3 4 5 2x17 0 132x476 FD200A FD200M 176 200 5 0 5 7 7 6 3 4 8 7 3 9 5 2x17 0 132x476 FD225A FD225M 201 225 5 7 6 4 8 7 3 9 9 7 4 4 5 2x17 0 132x476 FD250A FD250M 226 250 6 4 7 1 9 7 4 4 10 8 4 9 6 9x18 0 175x463 FD275A FD275M 251 275 7 1 7 8 10 8 4 9 11 9 5 4 6 9x18 0 175x463 FD300A FD300M 276 300 7 8 8 5 11 9...

Page 7: ...0 APPROVED FOR VERTICAL OR HORIZONTAL MOUNTING MODEL FD 1050 thru FD 1500 FOR VERTICAL MOUNTING ONLY Cubic Feet CU FT Kilograms KG Cubic Meters CU M Inches IN Pounds LBS Millimeters MM V M E O R U O T N N I T L C I Y A N L G 14 Step 5 Locate bracket in desired position Vertical Sensor Valve Detector Head Up or Horizontal Figure 2 Using the bracket as a template mark and drill holes in bulkhead and...

Page 8: ...6 or 7 a Before attaching cable to the cylinder check that the cylinder bracket is located correctly and firmly mounted b With the cylinder strapped in its bracket pass the cable jacket ferrule completely through the hole in the cylinder manifold This will allow the necessary cable flexibility needed for inserting the offset end of the flexible shaft into the actuator lever After connecting the sh...

Page 9: ...l and making to determine the applicable DOT specification The discharged extinguisher may be refilled upon the prepaid return of the discharged system Contact factory or authorized dealer for detail RETURN TO UNITED STATES SEA FIRE MARINE Division of Metalcraft Inc 9331 A Philadelphia Road Baltimore Maryland 21237 USA EUROPE SEA FIRE EUROPE LTD Unit 7 io Centre Stephenson Road Fareham Hampshire P...

Page 10: ...icate the ability to discharge the agent but not the quantity of extinguishing agent The cylinder less bracket must be weighed on at least a semiannual basis and be replaced immediately if gross weight has decreased by quantity noted on the specification label Never paint or obstruct the cylinder manifold or sensor valve detector as this will adversely affect its operating characteristic FD models...