Sea & Sea MDX-40D Instruction Manual Download Page 15

E-14

This model comes equipped with a strobe 
bulkhead (black: 

1

) and a TTL converter 

bulkhead (red: 

2

). 

CAUTION 

If you connect the YS series strobe sync 
cord to the bulkhead for TTL converter (red: 

2

), it could damage the pins on the bulkhead connector; so make sure never 

to do that. Likewise, if you connect the TTL converter’s camera connection 
cable to the strobe bulkhead (black: 

1

), it could damage the pins on the 

bulkhead connector; so make sure never to do that. 

1

Remove the housing’s bulkhead connector cap 

2

Make sure there are no scratches or 

debris on the O-ring of the sync cord 

being connected 

3

Align the round mark (the notch) of 

the sync cord with the round mark 

(the convex part) of the strobe 

bulkhead, and then push it straight in  

4

Align the B part of the sync cord with 

the screws of the strobe bulkhead, 

and then rotate it until it stops 

5

Rotate the C part of the sync cord until 

it stops 

z

Tighten it securely. 

z

When removing the sync cord, loosen C 
first, then B, and then pull the sync cord straight out holding onto A. Do not 
pull on the cord part. 

CAUTION 

z

After use underwater, make sure to prevent water droplets from dripping 
into the bulkhead connector by wiping moisture away from the bulkhead 
connector and then turning the housing upside down and extracting the 
sync cord. In the event that water droplets do drip into the connector, 
promptly wipe away all moisture. 

z

If you use incompatible strobes, not only might they not work correctly, but 
they may also cause the camera and the strobe to malfunction. 

Connecting the Strobe 

1

2

Sync cord

Strobe bulkhead 



Summary of Contents for MDX-40D

Page 1: ...English UNDERWATER HOUSING for Canon EOS 40D MDX 40D Instruction Manual...

Page 2: ...t at any time Safety Precautions E 2 Precautions on Handling the O ring E 4 Identification of Parts E 6 Leak Sensor E 7 Finder E 8 Opening and Closing the Housing E 9 Attaching and Detaching the Port...

Page 3: ...constructed with an airtight seal When packing the product for airplane travel do not seal up the product to alleviate pressure build up due to atmospheric changes z Do not open the product in a wet o...

Page 4: ...parts and resulting in potential fire or electric shock If the product is sealed tight in hot conditions heated air expanding inside the product may deform the casing and ruin the waterproofing z Do...

Page 5: ...ing effect of the O ring lasts as long as the silicone oil is gradually seeping out from within z For the maintenance of these blue O rings make sure to use genuine SEA SEA silicone grease O ring grea...

Page 6: ...e checked This is because you cannot find any sand or debris that may have gotten into the O ring groove if the O ring is not removed For routine maintenance prior to each use it is advisable to make...

Page 7: ...tion button LCD panel illumination button Finder Mode dial LCD monitor window Menu button Info Trimming orientation button Jump button Playback button Erase button Leak sensor Power switch Setting but...

Page 8: ...ssure inside the housing will increase which is very dangerous When releasing the locking latches the rear case could come flying off so be very careful Replacing the leak sensor battery Instructions...

Page 9: ...ng the finder 1 Rotate the finder unit mounted on the rear case in a counterclockwise direction to remove it z The screw areas are coated in grease so be careful not to touch them 2 Rotate the replace...

Page 10: ...ou lock the locking latch after it is removed from the hook it is easier to remove the rear case 1 Align the front case with the rear case and press them together 2 Put the right and left locking latc...

Page 11: ...ection until you hear the sound of it clicking into place z Make sure that the port lock pin is engaged with the notch in the port Detaching the port 1 Set the port lock to the OPEN position 2 Hold th...

Page 12: ...case 2 Using the included attachment tool fix the quick shoe to the camera s tripod socket 3 Attach the lens to the camera and then set the focus mode AF or MF 4 Make sure the quick lock is in the OP...

Page 13: ...the cord part it could damage the sync connector or cause contact failures 8 Align the mode dial on the camera with that on the rear case and then set the rear case 9 Close the locking latches See Op...

Page 14: ...he parts bracket shoe lanyard hook 2 Fit the TTL converter attachment plate in between the grip and the parts you removed and then fasten it in place with the screws included with the TTL converter CA...

Page 15: ...strobe bulkhead and then push it straight in 4 Align the B part of the sync cord with the screws of the strobe bulkhead and then rotate it until it stops 5 Rotate the C part of the sync cord until it...

Page 16: ...groove on the spacer z The focus zoom dial cannot be used if there is no gear mounted on the lens z When using a zoom gear you cannot shoot with manual focus When shooting without a focus zoom gear P...

Page 17: ...operate the AE lock button or the FE lock button follow the procedures below to change the position of the lever 1 Pull the lever in the direction of the arrow and keep it there 2 Rotate the collar in...

Page 18: ...air dryer for example Heating can deform and damage the product z If you will not use the product for an extended period of time store it away from high temperatures high humidity direct sunlight or e...

Page 19: ...Setting button AF start AE lock FE lock lever Multi controller Mode dial Menu button Erase button Playback button Info Trimming orientation button Picture style selection button Jump button Constructi...

Page 20: ...TEL 048 256 2251 TEL 048 255 8512 http www seaandsea co jp SEA SEA SUNPAK Co Ltd 3 2 20 Saiwai cho Kawaguchi shi Saitama Japan 332 0016 TEL 81 48 256 2251 World Customer Service Center TEL 81 48 255 8...