78
17. External ultrasonic sensors
They can be connected on all versions (
S
,
S+
,
M
,
M+
and
MD
). It is to be
reminded that the detector
SDT 170
will recognize the presence of the sensor and
will automatically change to the appropriate settings, scales and units.
It is insistently advised to refer to paragraph
Important note concerning
the plugging to the connector
on page 113 regarding the connecting
procedure, in order to avoid any premature deterioration of the connector
and the plug.
17.1 C
ONTACT PROBE
Main field of application
Use the contact probe for detecting and localizing bearing defects, gear meshes
problems, pump cavitations, steam trap failures, valve and reciprocating
compressor checks, and lubrication trending of rotating equipment.
Description
The contact probe is provided as a standard sensor with the
SDT 170 M
,
M
,
M+
and
MD
ultrasonic inspection kit. When plugged into the sensor input of the 170
the equipment switches to “contact measurement” mode. It is supplied with a
spiral cable with its appropriate connector.
The contact probe.
064
Summary of Contents for SDT170
Page 65: ...65 The battery packx...
Page 66: ...12 The Settings menu MAN 170 EN 04 SDT170 user manual Eng docx 66 141...
Page 73: ...15 Recharging the battery pack MAN 170 EN 04 SDT170 user manual Eng docx 73 141...
Page 74: ...74 Sensors and optionsx...
Page 75: ...Technical specifications MAN 170 EN 04 SDT170 user manual Eng docx 75 141...
Page 91: ...17 External ultrasonic sensors MAN 170 EN 04 SDT170 user manual Eng docx 91 141...
Page 116: ...116 Technical datax...
Page 117: ...MAN 170 EN 04 SDT170 user manual Eng docx 117 141...
Page 120: ...120 Appendixx...
Page 121: ...Appendix MAN 170 EN 04 SDT170 user manual Eng docx 121 141...
Page 135: ...26 Index MAN 170 EN 04 SDT170 user manual Eng docx 135 141...
Page 141: ...141 Your detector SDT 170 035...