4. Warranty obligations 

 

The  manufacturer guarantees the operation of product subject to the rules of exploitation 

set forth in the exploitation manual. 

Warranty period of set - 12 months from the date of sale. 
During the warranty period of exploitation the owner has the right to free repair in case of 

failure of the modulator. 

During the warranty period of exploitation, the repair is accomplished at the expense of the 

owner,  if  he  does  not  use  the  product  in  accordance  with  the  exploitation  manual,  does  not 
follow the recommendations of the manufacturer... 

The device is removed from the warranty in the following cases: 

 

If the device is opened;

 

 

If there is mechanical damage;

 

 

If the exploitation is not carried out in accordance with this user manual.

 

 
Current  modulator  M1-03  meets  technical  specifications  and  is  considered  suitable  for 
exploitation. 
Release Date ________________ 2015. 
Seller: ____________________________Stamp 
 
Brand of car (in which the equipment is installed): _____________________ 
Mileage at the time of installation: ____________ 
Set by: ________________ / __________________________ / 
Install Date: _____________

 

Summary of Contents for M1-03

Page 1: ...Current modulator 1 03 User Manual www sds max com ua...

Page 2: ...Page 1 Technical specifications 3 2 Completeness of set 4 3 Description of the current modulator setting 5 3 1 Connection of the current modulator 6 3 2 Current modulator setting 8 4 Warranty obligat...

Page 3: ...tors Present Maximum operating temperature of electrolyzer threshold of protection operation 77 Option Stabilization of the output current Present Protection against short circuit in the electrolyzer...

Page 4: ...2 Completeness O No Name Quantity Notes 1 Current modulator 1 2 User manual 1 3 Cord set 1 4 Detonation sensor 1 Only for diesel 5 Fuse 1...

Page 5: ...e the heating of the block at fairly high currents Modulator with a current sensor M1 03 is designed so that the limiting current is selected by the tuner and can be in the range of 5 35A The modulato...

Page 6: ...a terminal for fastening with the screw M8 supplied optionally Connection scheme of the modulator is shown in Fig 3 2 Note that the 12V supply or 24V is preferable to take from the terminals of the c...

Page 7: ...ith a current of 25 A the voltage will be 2 9 Volts Installation on the engine with carburetor Connect the blue wire to the terminal K can vary on the ignition coil or the cam of autotrembler If the t...

Page 8: ...el of modulator see Fig 3 6 Figure 3 6 Increasing of the sensitivity of the detonation sensor 3 2 Modulator setting The Modulator is set after electrolyzer system is set filling the system with soluti...

Page 9: ...tor The position of switches is set according to Table 3 1 Fig 3 8 Table 3 1 Compliance with the location of switches and current limitation Current A Location of switches No 1 No 2 No 3 4 35 ON ON ON...

Page 10: ...ordance with the exploitation manual does not follow the recommendations of the manufacturer The device is removed from the warranty in the following cases If the device is opened If there is mechanic...

Reviews: