Fuel Pre-filter, Change
1 Undo the cable from the water trap sensor.
2 Remove the water trap filter from the filter housing.
Collect any spilled fuel in a container.
3 Remove the lower part of the water trap from the
filter.
4 Clean the lower part of the water trap with a soft rag.
Check that the drain hole in the lower part is not
blocked.
5 Install a new seal on the lower part and lubricate the
seal with diesel fuel. Re-install the lower part of the
filter.
6 Lubricate the seal with diesel fuel. Screw the filter
onto the filter bracket by hand until the rubber seal
just touches the mating surface. Then tighten a fur-
ther half turn, no more.
7 Connect the cable to the water trap sensor.
8 If necessary, vent the fuel system, please refer to
Bleeding the Fuel System page 65
Draining condensate, fuel system
NOTICE!
Put a collection vessel under the fuel filter
tocollect the condensate and fuel.
1 Open the drain nipple (1) in the base of the fuel pre-
filter.
2 Tighten the drain tap (1) when fuel without water
starts to run out.
Bleeding the Fuel System
The system does not need to be purged unless it has
been run completely dry. Purging is then done with the
hand pump on the fuel filter bracket.
P0002103
1
P0002104
Maintenance
7748681 12-2011
65
193/297
Summary of Contents for R570U
Page 1: ...User and maintenance manual for generating sets R570U 33504081501NE_1_1 ...
Page 15: ...Alternator Cabinet Figure 1 3 Examples of identification plates 13 297 ...
Page 18: ...Sockets voltage 208 120V 16 297 ...
Page 125: ...9 Appendix 9 1 Appendix A Engine user and maintenance manual 123 297 ...
Page 126: ...124 297 ...
Page 128: ...126 297 ...
Page 129: ...OPERATOR S MANUAL Generating set and industrial engines 16 liter EMS 2 127 297 ...
Page 159: ...157 297 ...
Page 218: ...216 297 ...
Page 220: ...218 297 ...
Page 222: ...7748681 English 12 2011 220 297 ...
Page 223: ...9 2 Appendix B Alternator user and maintenance manual 221 297 ...
Page 224: ...222 297 ...
Page 226: ...224 297 ...
Page 250: ...www leroy somer com 248 297 ...
Page 261: ...Installation and maintenance R250 A V R 4067 en 2009 05 b LEROY SOMER 11 259 297 ...
Page 281: ...2012 03 e LEROY SOMER 19 Installation and maintenance R 450 AVRs 4531 en 279 297 ...
Page 282: ...www leroy somer com 280 297 ...