4.0 Back Panel Description
Page 5
AC Power
The DA-1G
is configured to operate on 100 to 240 VAC.
DC Power
If the DC Power option is installed, this instrument may also operate on DC power from
+12 to +36 VDC as the main power supply. When the DA-1G is set up to operate with both
AC and DC power sources at the same time the DC power is used as backup power in
case of AC power outages.
INPUT
A RF Signal within the range of 700 MHz to 1100 MHz may be connected to the SMA
connector labeled INPUT.
OUTPUTS
Twelve buffered copies of the RF input signal will be available at the SMA connectors
labeled OUTPUTS. Any DA-1G output may be used to drive the input of another
distribution amplifier.