4.0 Back Panel Description 

Page 5 

 
AC Power 

The DA-1G

 

is configured to operate on 100 to 240 VAC. 

 

DC Power  

If  the  DC  Power  option  is  installed,  this  instrument  may  also  operate  on  DC  power  from 
+12 to +36 VDC as the main power supply. When the DA-1G is set up to operate with both 
AC  and  DC  power  sources  at  the  same time  the  DC  power  is  used  as  backup  power  in 
case of AC power outages.  
 

INPUT 

A  RF  Signal  within  the  range  of  700  MHz  to  1100  MHz  may  be  connected  to  the  SMA 
connector labeled INPUT. 

 

OUTPUTS 

Twelve  buffered  copies  of  the  RF  input  signal  will  be  available  at  the  SMA  connectors 
labeled  OUTPUTS.  Any  DA-1G  output  may  be  used  to  drive  the  input  of  another 
distribution amplifier.  

 

Summary of Contents for DA-1G

Page 1: ...DA 1G 1 GHz DISTRIBUTION AMPLIFIER OPERATING MANUAL SPECTRADYNAMICS INC 1849 Cherry St Unit 2 Louisville CO 80027 Phone 303 665 1852 Fax 303 604 6088 www spectradynamics com SPECTRADYNAMICS INC...

Page 2: ...DA 1G 1 GHz Distribution Amplifier Operating Manual Copyright 2022 SpectraDynamics Inc All rights reserved DA 1G 2022MD...

Page 3: ...Safety and preparation for use 2 2 1 Electrical 2 2 2 Instrument 3 3 0 Front panel description 4 4 0 Back panel description 5 5 0 Installation 6 6 0 Operation 7 7 0 Troubleshooting 8 8 0 Specification...

Page 4: ......

Page 5: ...level monitor that compares the twelve output power levels to a preset threshold of 7 dBm If the signal on any output drops below this threshold the monitor LED located on the front panel will turn of...

Page 6: ...Only replace fuse with the same type and specifications AC Power The instrument has a detachable three wire power cord for connection to a grounded AC power source The enclosure of the unit is direct...

Page 7: ...low these directions may cause injury or death to personnel cause irreparable damage to the instrument and voids all warranties If you provide DC power to the unit detaching the DC power cord is the o...

Page 8: ...is installed the DC Power LED will be on when DC power is applied to unit Monitor LED The monitor LED will be on if all RF outputs are greater than 7 dBm RF signal levels less than 7 dBm will trigger...

Page 9: ...1G is set up to operate with both AC and DC power sources at the same time the DC power is used as backup power in case of AC power outages INPUT A RF Signal within the range of 700 MHz to 1100 MHz ma...

Page 10: ...the AC POWER entry module on the rear of the enclosure and connect the power cord The amplifier units that are acquired with the DC operation option are shipped with a DC connector part number RM12BPE...

Page 11: ...nuous operation Once AC power is supplied to the DA 1G the LED on the front panel labeled AC POWER will turn on If you also applied DC voltage the LED labeled DC POWER will also turn on The DA 1G is d...

Page 12: ...and DC power cords Remove the top cover Check the DC power fuse and power cord If the fuse is blown replace with same type and rating Please contact SpectraDynamics if any of the fuses blows again or...

Page 13: ...ironment 0 to 50 C Humidity 5 to 95 Non condensing PARAMETER CONDITIONS MIN TYP MAX UNITS Output power level 1 dB compression 13 dBm Bandwidth 1 dB 800 1100 MHz Gain 1 GHz 0 5 0 5 1 5 dB Impedance Inp...

Page 14: ...ion or any liability for direct indirect or consequential damages or delay Any improper use operation beyond capacity substitution of parts not approved by SDI or any alteration or repair by others in...

Page 15: ...ertain voltage limits 2014 30 EU The Electromagnetic Compatibility Directive and its amending directives 2011 65 EU of the European Parliament and of the Council of 8 June 2011 on the restriction of t...