SDC 950 ENTRYCHECK Installation & Programming Instructions Download Page 6

950 ENTRYCHECK

MASTER CARD ENROLLMENT TROUBLESHOOTING GUIDE

WHAT IS A MASTER CARD

The master card is the one card used to access  the programming mode of the 950. Once enrolled, it 
can be used in place of  the master code at time of programming. Although  the card is the same 
physical type of card as a user card, the 950 treats  it in a different way. When you enroll a card as the 
master card, the 950 not only reads the serial number of the card (like it does when it enrolls a user card) 
but also programs a special code into a memory chip located on the card itself. When the card is 
presented to the 950, both the serial number and the special code are read for validation. 

MASTER CARD ENROLLMENT PROBLEMS

If  programmed, the program card will no longer function as a user card  or as a master card for another 
unit without first erasing the card's internal memory chip.They usually come from the manufacturer fully 
erased and ready to enroll as either a master or user card.  Occasionally  a card may need to be erased 
again before it will be accepted as a master card at time of enrollment.  This is the procedure: 

RESET  THE 950 TO FACTORY DEFAULT SETTINGS 

Disconnect Power.
While depressing both the     &  # keys, apply power. The LED will flash 

green

  and then after a few 

seconds will turn 

red

. This resets the master code to the default '000000'. To erase all user cards and 

settings as well as the master code, continue depressing the     &  #  keys until the 

red

 LED goes out. 

Remove power.
Release the     &  # keys.
Wait 5 seconds.
Reapply power.

ERASE THE CARD

Apply Power.
Enter      000000      (the unit is now in programming mode).
Enter 7      (LED flashes 

green

).

Present the card  to be erased and remove (1 beep). 
Enter

#

(6 beeps and the unit is now out of programming mode again).

The card is now erased and ready to be enrolled as a master card.

P:\INSTALLATION INST\Access Controls\INST-950\INST-950.vsd     REV G     0605     Page 6

Summary of Contents for 950 ENTRYCHECK

Page 1: ...s and or PIN Codes Choice of three entry modes Proximity Reader only Proximity Reader or PIN Code Proximity Reader and PIN Code Up to 6 inch 152 mm reader range Add change delete cards and PINs Programmable door unlock time from 1 99 seconds Tamper alarm and reader PIN lockout Request To Exit input Two outputs lock relay and alarm relay LED and audible tone for operation ease Weather resistant ORD...

Page 2: ...r 1 beep green LED Enter starting user number 001 499 Enter 1 beep green LED Present first sequential card Enter 4 digit PIN number 1 beep LED flashing red green Enter to exit 6 beeps LED flashing yellow DELETE CARD Enter Present Master card to reader and Enter Remove 6 beeps LED flashing red green Enter 7 LED flashing green Present card to be deleted to reader and remove 1 beep Enter 6 beeps OR E...

Page 3: ...User Number Name Card Number PIN Code User Number Name Card Number PIN Code P INSTALLATION INST Access Controls INST 950 INST 950 vsd REV G 0605 Page 3 ...

Page 4: ...st to exit input M Common for REX Alarm Input E Door Contact PIN OUTS AT1 Anti Tamper Switch ST2 Jumper for Relay 1 RL1 Door Relay RL2 Alarm Relay V1 Varistor PB1 REX Push Button LEGEND N C contact RL1 magnet N O contact RL1 ST2 1 1 3 3 STRIKE V1 Power Supply V 12VDC 110VAC PB1 2 1 E M B 3 5 T C O 12 V RL2 RL1 AT1 ST2 3 1 1 2 3 TR12 POWER SUPPLY 12VDC 150mA REGULATED OUTPUT 12VDC 780mA MAX USE WIT...

Page 5: ...e 950 EntryCheck Wiring access Area 3 75 5 mm 2 7 16 61 mm 1 38 mm 9 1 16 15 mm 23 mm P INSTALLATION INST Access Controls INST 950 INST 950 vsd REV G 0605 Page 5 20 5mm 1 43mm 411 16 120mm 4 105mm 55 16 135mm ...

Page 6: ... the card s internal memory chip They usually come from the manufacturer fully erased and ready to enroll as either a master or user card Occasionally a card may need to be erased again before it will be accepted as a master card at time of enrollment This is the procedure RESET THE 950 TO FACTORY DEFAULT SETTINGS Disconnect Power While depressing both the keys apply power The LED will flash green...

Reviews: