SDC 950 ENTRYCHECK Installation & Programming Instructions Download Page 4

WIRING DIAGRAM

PCB front view

INSTALLATION SETTINGS

Typical Wiring (single door)

P:\INSTALLATION INST\Access Controls\INST-950\INST-950.vsd     REV G     0605     Page 4

WARNING

Do not use a 
switching power 
supply.  The 
interference 
radiation may 
disturb the 
reading of 
badges.

V

Return or V-

12

+12 VDC

O

Relay 1 contact (ST2)

C

Relay common

T

Relay 2 N/O contact

B

Request-to-exit input

M

Common for REX & Alarm Input

E

Door Contact

PIN-OUTS

AT1

Anti-Tamper Switch

ST2

Jumper for Relay 1

RL1

Door Relay

RL2

Alarm Relay

V1

Varistor

PB1 REX Push Button

LEGEND

N/C contact RL1 (magnet)
N/O contact RL1

ST2

1
1

3
3

STRIKE

V1

Power 

Supply  +V

12VDC

110VAC

PB1

2   1   E  M  B   3   5   T  C  O  12  V

RL2  RL1

AT1

ST2

3

1

1

2

3

TR12

POWER

SUPPLY

12VDC
150mA
REGULATED
OUTPUT

12VDC

780mA MAX

(USE WITH NON-SDC LOCKS)

REQUEST TO EXIT
REX (N/O)

MOV

ELECTRIC
LOCK

(750mA MAX)

SET JUMPER ST2
FOR LOCK TYPE
FAIL SAFE (N/C)
FAIL SECURE (N/O)

950

12   V   C    O   – - M   B

Not Used

Summary of Contents for 950 ENTRYCHECK

Page 1: ...s and or PIN Codes Choice of three entry modes Proximity Reader only Proximity Reader or PIN Code Proximity Reader and PIN Code Up to 6 inch 152 mm reader range Add change delete cards and PINs Programmable door unlock time from 1 99 seconds Tamper alarm and reader PIN lockout Request To Exit input Two outputs lock relay and alarm relay LED and audible tone for operation ease Weather resistant ORD...

Page 2: ...r 1 beep green LED Enter starting user number 001 499 Enter 1 beep green LED Present first sequential card Enter 4 digit PIN number 1 beep LED flashing red green Enter to exit 6 beeps LED flashing yellow DELETE CARD Enter Present Master card to reader and Enter Remove 6 beeps LED flashing red green Enter 7 LED flashing green Present card to be deleted to reader and remove 1 beep Enter 6 beeps OR E...

Page 3: ...User Number Name Card Number PIN Code User Number Name Card Number PIN Code P INSTALLATION INST Access Controls INST 950 INST 950 vsd REV G 0605 Page 3 ...

Page 4: ...st to exit input M Common for REX Alarm Input E Door Contact PIN OUTS AT1 Anti Tamper Switch ST2 Jumper for Relay 1 RL1 Door Relay RL2 Alarm Relay V1 Varistor PB1 REX Push Button LEGEND N C contact RL1 magnet N O contact RL1 ST2 1 1 3 3 STRIKE V1 Power Supply V 12VDC 110VAC PB1 2 1 E M B 3 5 T C O 12 V RL2 RL1 AT1 ST2 3 1 1 2 3 TR12 POWER SUPPLY 12VDC 150mA REGULATED OUTPUT 12VDC 780mA MAX USE WIT...

Page 5: ...e 950 EntryCheck Wiring access Area 3 75 5 mm 2 7 16 61 mm 1 38 mm 9 1 16 15 mm 23 mm P INSTALLATION INST Access Controls INST 950 INST 950 vsd REV G 0605 Page 5 20 5mm 1 43mm 411 16 120mm 4 105mm 55 16 135mm ...

Page 6: ... the card s internal memory chip They usually come from the manufacturer fully erased and ready to enroll as either a master or user card Occasionally a card may need to be erased again before it will be accepted as a master card at time of enrollment This is the procedure RESET THE 950 TO FACTORY DEFAULT SETTINGS Disconnect Power While depressing both the keys apply power The LED will flash green...

Reviews: