PROGRAM MASTER CARD
Apply power (LED flashing
yellow
).
Enter
000000
(6 beeps).
Enter
2
(LED flashing
green;
1 beep).
Present Master card to reader and
Remove (LED flashing
green
; 1 beep).
Enter
#
(LED flashing
yellow
; 6 beeps).
PROGRAM UNLOCK TIME (Default is 1 sec)
Enter .
Present Master card to reader and Enter .
Remove (6 beeps).
Enter
4
(LED flashing
green
).
Enter delay on relock time
(i.e. 03 = 3 sec.). Default is 1 sec.
Enter (1 beep,
green
LED).
Enter
#
(6 beeps).
Note: 00 = Toggle
PROGRAMMING ENTRY MODE
Choose the mode of entry you require.
0 = CARD and PIN (Default)
1 = CARD Only
2 = CARD or PIN
-------------------
Enter .
Present Master card to reader and Remove (6 beeps).
Enter
5
(LED flashing
green
).
Enter 0, 1 or 2.
Enter
#
(6 beeps).
PROGRAMMING ONE CARD & PIN
Enter (1 beep,
green
LED).
Present Master card to reader.
Remove (6 beeps).
Enter
1
(LED flashing
green
).
Enter
01 001
(delayed 1 beep). (001-499)
Present new card to reader and remove (1 beep).
Key in any 4 digit PIN for new card (1 beep).
Enter
#
(6 beeps).
Repeat above for every card to be entered.
CARD BATCH PROGRAMMING
Note: PIN will be the same for all cards
programmed in the batch mode.
Enter (1 beep,
green
LED).
Present Master card to reader and Enter .
Remove (6 beeps, LED flashing
red & green
).
Enter 1 (1 beep, LED flashing
green
).
Enter number of cards to be programmed (01-99).
Enter (1 beep,
green
LED).
Enter starting user number (001-499).
Enter (1 beep,
green
LED).
Present first sequential card.
Enter 4 digit PIN number (1 beep; LED flashing
red & green
).
Enter
#
to exit (6 beeps; LED flashing
yellow
).
DELETE CARD
Enter . Present Master card to reader and Enter .
Remove (6 beeps, LED flashing
red & green
).
Enter 7 (LED flashing
green
).
Present card to be deleted to reader and remove (1 beep).
Enter
#
(6 beeps).
OR
Enter .
Present Master card to reader and Enter .
Remove (6 beeps).
Enter 7 (LED flashing
green
).
Key in last six numbers located on card to be deleted.
Enter (1 beep).
Enter
#
(6 beeps).
RESET TO FACTORY DEFAULTS &
DELETE MASTER CARD
Disconnect power.
While depressing both the and
#
keys, apply power. The
LED will flash
green
and then after a few seconds will turn
red
. This resets the master code to the default ‘000000’. To
erase all user cards and settings as well as the master code,
continue depressing the &
#
keys until the
red
LED goes
out.
Remove power.
Release the &
#
keys.
Wait 5 seconds.
Reapply power.
NOTE:
•
When programming a new card you must enter first to enter the programming mode and present the Master Card.
•
PIN needs to be programmed for each new card even if CARD only entry mode is chosen.
•
Yellow
LED flashing may also be viewed as an alternating
red and green
LED.
•
The
#
key exits the programming mode (LED flashing
yellow
).
•
Keep a log of each card issued. See sample log on following page.
P:\INSTALLATION INST\Access Controls\INST-950\INST-950.vsd REV G 0605 Page 2