Configure Sense Input  

Default:  INHIBIT 

The Sense Input (gray wire) can be programmed for either 
DOOR SENSE or INHIBIT.

Press:  10 # Input #

Input=0 for Door Sense; =1 for Inhibit

When programmed for DOOR SENSE, if an open condition on 
the input occurs before access is granted (with an entry code or 
with the request-to-enter input) a FORCED ENTRY output will 
occur.  If an open condition remains 60 seconds after a relay 
activation for access, a DOOR AJAR output will occur.  

When programmed for INHIBIT, a closed condition on the input 
will prevent Relay #1 from activating when access is requested 
with an entry code.  This mode is typically used with an external 
timer to disable the access device at certain times.

Select Forced Entry Output

Default:  No Output

Sets which output activates if the DOOR SENSE input opens 
before access is granted.  This output is timed and configured 
by the relay “On-time”.

Press:  11 # Output #

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4;  

0=No Output

Select Door Ajar Output

Default:  No Output

Sets which output activates if the DOOR SENSE input stays 
open 60 seconds after access is granted (door ajar time is 
adjustable using Function 25).  This output is not timed.

Press:  12 # Output #

Output=Output to Activate (0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4;  

0=No Output

Select Keypad Active Output

Default:  No Output

Sets which output activates when any keys are pressed.  This 
output is timed.  If toggle mode is selected for the output, the timer 
value defaults to 2 seconds.

Press: 14 # 

Output

#  

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4; 

0=No Output

Select Keypad Lockout Output

Default:  No Output

Sets which output activates when the keypad is “locked out” after 
too many incorrect entry code attempts. The lockout time is 60 
seconds.

Press: 13 # 

Output

#  

Output=Output to Activate (0-4)

1=Main Relay;  2 = Auxiliary Relay;  3=Output #3; 4=Output #4;  

0=No Output / Lockout Disable

Select Alarm Shunt Output

Default:  No Output

Sets which output activates during the time access is granted.  
(Use this output ot shunt alarm contacts attached to the access 
door.)  This output may be timed or toggled.

Press: 15 # 

Output

#  

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4; 

0=No Output

Select Request-to-Exit Output

Default:  No Output

Sets which output activates when the Request-to-Exit input is 
grounded.  This output may be timed or toggled.

Press: 16 # 

Output

#  

Output=Output to Activate(0-4)

1=Main Relay;  2=Auxiliary Relay;  3=Output #3;  4=Output #4; 

0=No Output

REX input terminates toggle of Main or Aux. Relay

Main Relay On-time

Default:  02 Seconds

Sets the length of time the Main Relay activates when triggered.

Green LED is on when Main Relay is active.

Press: 21 # 

Seconds

#  

Seconds=Output time in seconds (1-60)

Auxiliary Relay On-time

Default:  02 Seconds

Sets the length of time the Auxiliary Relay activates when triggered.

Press: 22 # 

Seconds

#  

Seconds=Output time in seconds (1-60)

P:\INSTALLATION INST\Access Controls\INST-920\INST-920P.vsd     Rev G     01-18     Page 5

(Typical Programming cont.)

See the following example that sets entry codes 1234 for normal 
operation and 5678 for toggle operation.

Press:  01 # User # 1 2 3 4 # 1 2 3 4 # 1 #

01=Programming Step;  1234=Entry Code;  1=Main Relay

Press:  01 # User # 5 6 7 8 # 5 6 7 8 # 20 #

01=Programming Step;  5678=Entry Code;  20=Auxiliary Relay

toggle

Anti-Tamper Output

Default:  No Output

Sets which output activates when the Anti Tamper switch on the 
back of the keypad is activated. 

Press: 17 # 

Output

#  

Output=Output to Activate(0-4)

0=No Output;  2=Auxiliary Relay;  3=Output #3;  4=Output #4;  

Erasing All Entry Codes

WARNING:  PERFORMING THIS COMMAND WILL REMOVE 

ALL ENTRY CODES FROM THE MEMORY

Press: 97 # 0 0 0 0 0 0 #  0 0 0 0 0 0 #  

Note: 

The green indicator will light while the memory is being 

erased.  This may take up to 15 seconds.

Erasing Multiple Users (Sequential)

Press: 09 # 1

st

User

# Number of users #  

1

st

User =Starting user number to delete

Number of users = Total number of consecutive users  to delete

The yellow indicator will flash quickly while the 920P erases the 
user from  memory.  The green indicator will light when the code is 
erased.

Summary of Contents for 920P EntryCheck

Page 1: ...ide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to activate any of...

Page 2: ...ramming mode default master code Step 2 Enter 01 003 2580 2580 1 Assign User 003 with a PIN code of 2580 Activate the main relay when entered Step 3 Repeat Step 2 to enter another unique user PIN or c...

Page 3: ...er earth ground Connect the green earth ground wire to a good earth grounding point Suggested wiring size is 18 AWG for earth ground Sense Input RE Note The SENSE input gray wire can be programmed as...

Page 4: ...open Relay 2 toggled The yellow indicator will flash quickly while the 920P stores the new user information in memory The green indicator will light when the new code and card are accepted If the use...

Page 5: ...larm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door This output may be timed or toggle...

Page 6: ...ps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length of time Output 4 activates when triggered Press 24 Seconds Secon...

Page 7: ...Access Controls INST 920 INST 920P vsd Rev G 01 18 Page 7 5 750 1 375 3 000 MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X Mount at slots 4X Mount at holes With supplied screws and hole expansion anc...

Page 8: ...P INSTALLATION INST Access Controls INST 920 INST 920P vsd Rev G 01 18 Page 8 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD 4X Mount at holes POST MOUNT WITH SHROUD 4 4...

Reviews: