P:\INSTALLATION INST\Access Controls\INST-920\INST-920P.vsd Rev G 01-18 Page 2
Test your new user
Present your card or enter an authorized PIN code + #. The green indicator should
illuminate and the main relay should activate, unlocking the door for 5 seconds.
CAUTION
IF THE UNIT IS AC POWERED, MAKE SURE
THAT THE SECONDARY OF THE SYSTEM IS
ISOLATED FROM EARTH GROUND
!
!
RED/GREEN
POWER/ACCESS/ERROR
INDICATOR
YELLOW
“PROGRAM”
INDICATOR
KEYPAD
FRONT
PROX
Antenna
Fig. 2 Wiring Pigtail Color Code
}
AUXILIARY RELAY
2 AMPS @ 28VDC MAX
NO
COM
ORG/BLK
BLK/WHT
BRN/YEL
NC
TO POWER SUPPLY
KEYPAD POWER
12 or 24 VOLTS
AC OR DC
}
+
-
RED
BLACK
MAIN RELAY
5 AMPS @ 28VDC MAX
}
NO
COM
NC
ORANGE
WHITE
YELLOW
Set default parameters (first time use)
Step 1. Enter:
#9# 123456#
Enter programming mode (default master code=123456)
Step 2. Enter:
03# 4#
Set the entry code length to 4 digits
Step 3. Enter:
21# 5#
Set the main relay activation time for 5 sec.
Step 4. Enter:
#
Exit programming mode
**
**
Assign a user (Card only)
Step 1. Enter:
#9# 123456#
Enter programming mode (default master code)
Step 2. Enter:
06# 002# 9876# 9876# 1# (Present card)
Assign card to User 002 with a
PIN code of ‘9876’. Activate
the main relay when validated.
Step 3. Repeat Step 2 to enter another unique user & card, or continue to Step 4.
Step 4. Enter:
#
Exit programming mode.
Assign a user (PIN only)
Step 1. Enter:
#9# 123456#
Enter programming mode (default master code)
Step 2. Enter:
01# 003# 2580# 2580# 1#
Assign User 003 with a PIN code of ‘2580’.
Activate the main relay when entered.
Step 3. Repeat Step 2 to enter another unique user & PIN or continue to Step 4.
Step 4. Enter:
#
Exit programming mode
**
Deleting a user code
Step 1. Enter:
#9# 123456#
Enter programming mode (default master code)
Step 2. Enter:
02# 002# 002#
User 002 has been deleted.
Step 3. Enter:
#
Exit programming mode
**
QuickStart Programming
You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the 920P
EntryCheck™ is in programming mode. Use the option codes to program each function. After the new data entry is complete for
each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the
programming has been accepted. The red indicator will light if any programming data is entered incorrectly or the function is
rejected. If a red indicator is seen, the entire function (option code + data) will have to be fully re-entered. The keypad will remain
in programming mode until # is pressed or after 30 seconds of inactivity.
**
KEYPAD
POWER
WIRE
HARNESS
(E1-E8)
MAIN
RELAY
AUXILIARY
RELAY
ANTI-TAMPER
SWITCH
BACK
JP1
E1
E8
JP2
Grn Wire
To earth ground
BLACK
PINK/SALMON
GREEN
GRAY
BLACK
VIOLET
BLACK
BLUE
DOOR POSITION
SWITCH
[N/C]
REQUEST-TO-EXIT
SWITCH
[N/O]
GROUND
OUTPUT #4
OUTPUT #3
GROUND
SENSE
REQUEST TO EXIT
GROUND
E
1
E
8
E
7
E
6
E
5
E
4
E
3
E
2
C
NO
C
NC
NO
AUXILIARY OUTPUTS
100mA MAX TO COMMON
{
*
*
NOT USED