background image

P:\INSTALLATION INST\Access Controls\INST-920\INST-920P.vsd     Rev G     01-18     Page 2

Test your new user

Present your card or enter an authorized PIN code + #. The green indicator should 

illuminate and the main relay should activate, unlocking  the door for 5 seconds.

CAUTION

IF THE UNIT IS AC POWERED, MAKE SURE

THAT THE SECONDARY OF THE SYSTEM IS 

ISOLATED FROM EARTH GROUND

!

!

RED/GREEN
POWER/ACCESS/ERROR
INDICATOR

YELLOW
“PROGRAM”
INDICATOR

KEYPAD

FRONT

PROX 

Antenna

Fig. 2 Wiring Pigtail Color Code

}

AUXILIARY RELAY

2 AMPS @ 28VDC MAX

NO

COM

ORG/BLK

BLK/WHT

BRN/YEL

NC

TO POWER SUPPLY

KEYPAD POWER

12 or 24 VOLTS

AC OR DC

}

+

-

RED

BLACK

MAIN RELAY

5 AMPS @ 28VDC MAX

}

NO

COM

NC

ORANGE

WHITE

YELLOW

Set default parameters (first time use)

Step 1. Enter:  

#9#  123456#

Enter programming mode (default master code=123456)

Step 2. Enter: 

03#  4# 

Set the entry code length to 4 digits

Step 3. Enter:  

21# 5#

Set the main relay activation time for 5 sec.

Step 4. Enter:  

#  

Exit programming mode

**

**

Assign a user  (Card only)

Step 1. Enter:  

#9#  123456#    

Enter programming mode (default master code)

Step 2. Enter:  

06#  002# 9876# 9876# 1# (Present card) 

Assign card to User 002 with a

PIN code of ‘9876’. Activate
the main relay when validated.

Step 3. Repeat Step 2 to enter another unique user & card, or continue to Step 4.

Step 4. Enter:  

#  

Exit programming mode.

Assign a user  (PIN only)

Step 1. Enter:  

#9#  123456#    

Enter programming mode (default master code)

Step 2. Enter:  

01#  003# 2580# 2580# 1#    

Assign User 003 with a PIN code of ‘2580’. 
Activate the main relay when entered.   

Step 3. Repeat Step 2 to enter another unique user & PIN or continue to Step 4.

Step 4. Enter:  

#  

Exit programming mode

**

Deleting a  user code

Step 1. Enter:  

#9#  123456#

Enter programming mode (default master code)

Step 2. Enter:  

02#  002# 002# 

User 002 has been deleted. 

Step 3. Enter:  

#  

Exit programming mode

**

QuickStart  Programming

You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the  920P 
EntryCheck™ is in programming mode. Use the option codes to program each function.   After the new data entry is complete for 
each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the 
programming has been accepted.  The red indicator will light if any programming data is entered incorrectly or the function is 
rejected. If a red indicator is seen, the entire function (option code + data)  will have to be fully re-entered.  The keypad will remain 
in programming mode until        # is pressed or after 30 seconds of inactivity.

**

KEYPAD
POWER

WIRE
HARNESS
(E1-E8)

MAIN
RELAY

AUXILIARY
RELAY

ANTI-TAMPER
SWITCH

BACK

JP1

E1

E8

JP2

Grn Wire
To earth ground

BLACK

PINK/SALMON

GREEN

GRAY

BLACK

VIOLET

BLACK

BLUE

DOOR POSITION 

SWITCH

[N/C]

REQUEST-TO-EXIT 

SWITCH

[N/O]

GROUND

OUTPUT #4

OUTPUT #3

GROUND

SENSE

REQUEST TO EXIT

GROUND

E

1

E

8

E

7

E

6

E

5

E

4

E

3

E

2

C

NO

C

NC

NO

AUXILIARY OUTPUTS

100mA MAX TO COMMON

{

*

*

NOT USED

Summary of Contents for 920P EntryCheck

Page 1: ...ide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to activate any of...

Page 2: ...ramming mode default master code Step 2 Enter 01 003 2580 2580 1 Assign User 003 with a PIN code of 2580 Activate the main relay when entered Step 3 Repeat Step 2 to enter another unique user PIN or c...

Page 3: ...er earth ground Connect the green earth ground wire to a good earth grounding point Suggested wiring size is 18 AWG for earth ground Sense Input RE Note The SENSE input gray wire can be programmed as...

Page 4: ...open Relay 2 toggled The yellow indicator will flash quickly while the 920P stores the new user information in memory The green indicator will light when the new code and card are accepted If the use...

Page 5: ...larm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door This output may be timed or toggle...

Page 6: ...ps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length of time Output 4 activates when triggered Press 24 Seconds Secon...

Page 7: ...Access Controls INST 920 INST 920P vsd Rev G 01 18 Page 7 5 750 1 375 3 000 MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X Mount at slots 4X Mount at holes With supplied screws and hole expansion anc...

Page 8: ...P INSTALLATION INST Access Controls INST 920 INST 920P vsd Rev G 01 18 Page 8 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD 4X Mount at holes POST MOUNT WITH SHROUD 4 4...