background image

FACTORY DEFAULTS

Master Programming CodeYYY..YYYYYYY.Y.Y...123456  
Entry Code LengthYYYYYYYYYYYYYYY.YY..4 digits
Entry  ModeYY..YYYYYYYYYYYYYY.Y...Card or PIN
Request-to-exit Output RelayYYYYYYYYY..........No Output
Alarm Shunt OutputY.YYYYYYYYYYYYY.........Disabled
Forced Entry OutputYYYYYYYYYYY..YYYYNo Output
Door Ajar OutputYYYYYYYYYYYYY..YY.Y.No Output
Main Relay On TimeYYYYYYYYYYYYY..Y..02 Seconds
Auxiliary Relay On TimeYYYYYYYYYYY.....Y02 Seconds
Solid State Output #3 On TimeYYYYYYYYY......02 Seconds
Solid State Output #4 On TimeYYYYYYYYYY..02 Seconds
Door Sense/Inhibit InputYYYYYYYYYY...YY..Door Sense
Keypad Lockout OutputYYYYYYYYYYYY..YY.Disabled
Keypad Active OutputYYYYYYYYYYYY..Y..Y..Disabled
Beeper Sounds When Key PressedYYYYYYYY...YYYYes
Beeper Sounds During Relay #1YYYYYYYYY..Y...YY.No
Beeper Sounds During Relay #2YYYYYYYYYYY...Y...No
Beeper Sounds During Output #3YYYYYYYYYYY........No
Beeper Sounds During Output #4YYYYYYYYYYY........No
Keypad Lockout CountYYY.YYY......Y.3 Tries Before Lockout
Anti-Passback TimeYYYYYY..YY...YYY.No Anti-Passback
Auto-RelockYYYYYYYYYYYYY...YYYY.YYYY.On

BASIC PROGRAMMING

When the 920P EntryCheck™ is in Programming Mode the yellow 
indicator will blink slowly.  After a programming command is 
selected, the yellow indicator will flash rapidly while the keypad is 
waiting for user input data.  The green indicator will light if the data 
is accepted.  The red indicator will light if any programming data is 
entered incorrectly, and the command will have to be fully re-
entered.  IMPORTANT!:Cards & Codes are stored by User #.  It is 
imperative that the User numbers and their assigned personnel 
are managed in the event a specific user everneeds to be deleted.

Entering Programming Mode

The 6-digit Master Programming Code (default = 123456) is used 
to enter Programming Mode.

Press:  # 9 # Master Code #

Master Code = the current 6-digit Master Programming Code

Setting Entry Code Length

Default: 4 digits

Press: 03 # 

Length

#  

Length = 1-6 for entry code length

Note: 

If the Entry Code Length is going to be changed from the factory 

default of 4 digits, make this change first before programming any entry 
codes.

Adding a New User

User PIN Only Access (No Card)

Press: 01 # User # 

Code

#  

Code # Relay #

---- Or ----

User Card and or  PIN Access

Press: 06 # User # 

Code

#  

Code # Relay # Present Card

User

=3-digit User number to be added: 001-500  

Code

=The new entry code: 1-999999, depending on code length

Relay

=Relay output entry code will activate:

1=Main Relay   2=Auxiliary Relay   3=Both Relays
10=Relay #1, toggled  20=Relay #2, toggled  30=both Relays toggled
12=Relay #1 toggled; Relay #2 timed open
21=Relay #1 timed open; Relay #2 toggled

The yellow indicator will flash quickly while the 920P stores the new 
user information in memory  The green indicator will light when the 
new code and card are accepted. If the user number already exists 
or an entry error has been made, the red indicator will light.  Delete 
the user and re-enter the new information again.

Note:

Leading zeros (zeros before the code number, i.e.0001) do not need to 

be entered when programming a new code.  The 920 will internally add any 
zeros to fill digits determined by the entry code length setting.  Leading zeros 
will have to be entered by the user when entering their code to gain access.

Erasing a Single User

Press: 02 # 

User

#  

User

#  

User =The user number to delete  001-500

The yellow indicator will flash quickly while the 920P erases the 
user from memory.  The green indicator will light when the code is 
erased.

Output Toggle Mode

When an output is programmed for Toggle Mode, the output 
alternates from OFF to ON or from ON to OFF each time it is 
accessed.  When an output is toggled on, the green LED remains 
solid until toggled off.

The rules for a toggle output are:

If the output is OFF, it will turn ON and stay on until the next 
activation.
If the output is ON, it will turn OFF and stay off until the next 
activation.
An authorized PIN, Card, or REX input programmed to 
momentarily activate that same relay will reset the relay to its 
normal state.

P:\INSTALLATION INST\Access Controls\INST-920\INST-920P.vsd     Rev G     01-18     Page 4

Re-entering a Command After a Mistake

If the red indicator lights, signaling an incorrect entry, or an 
incorrect key is pressed during programming, to clear the keypad 
and re-enter the command:

Press:      9 #  

*

Adding  Multiple Sequential Cards

Press: 08 # 1

st

User

# Code # Code # Relay # Number of users

# Present 1

st

card 

1

st

User =Starting user number to add

Number of users = Total number of consecutive cards  to add

After presenting the 1

st

card, the green indicator will light as cards 

are added.  NOTE:  The “Code” will be the same for all users, but 
may be changed for each user using Function 04 below.

Select Entry Mode

Default:  Card or PIN

Sets the entry mode for the 920P.

Press:  05 # Mode #

Mode=Operating Mode(1-3)

1=Card or PIN;  2=Card Only  3=Card and PIN

Exiting Programming Mode

Press:        # 

The red indicator will light after exiting Programming Mode

Note: 

The 920P will automatically exit Programming Mode after 

30 seconds of inactivity

**

Adding  Multiple Non-Sequential Cards

Press: 07 # 1

st

User

# Code # Code # Relay # Number of users

# Present 1

st

card, Present 2

nd

card, G, Present last card 

1

st

User =Starting user number to add

Number of users = Total number of consecutive cards  to add

Changing a User PIN

Press: 04 # 

User

# New Code #  New Code #  

User =The user number whose PIN will be changed

Summary of Contents for 920P EntryCheck

Page 1: ...ide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to activate any of...

Page 2: ...ramming mode default master code Step 2 Enter 01 003 2580 2580 1 Assign User 003 with a PIN code of 2580 Activate the main relay when entered Step 3 Repeat Step 2 to enter another unique user PIN or c...

Page 3: ...er earth ground Connect the green earth ground wire to a good earth grounding point Suggested wiring size is 18 AWG for earth ground Sense Input RE Note The SENSE input gray wire can be programmed as...

Page 4: ...open Relay 2 toggled The yellow indicator will flash quickly while the 920P stores the new user information in memory The green indicator will light when the new code and card are accepted If the use...

Page 5: ...larm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door This output may be timed or toggle...

Page 6: ...ps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length of time Output 4 activates when triggered Press 24 Seconds Secon...

Page 7: ...Access Controls INST 920 INST 920P vsd Rev G 01 18 Page 7 5 750 1 375 3 000 MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X Mount at slots 4X Mount at holes With supplied screws and hole expansion anc...

Page 8: ...P INSTALLATION INST Access Controls INST 920 INST 920P vsd Rev G 01 18 Page 8 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD 4X Mount at holes POST MOUNT WITH SHROUD 4 4...

Reviews: