background image

ScyTek  Electronics

11627 Cantara Street 

North Hollywood, CA 91605

www.scytek.net

© ScyTek Electronics 2006

Astra A10  7-10-06

Wiring  Diagram

FCC ID: OARRXAM2000

This device complies with Part 15 of FCC Rules.

Operation is subject to the following two conditions:

1) This device may not cause harmful interference.

2) This device must accept any interference received, including interference that may cause

undesired operation

Technical  Information

 

Impact Sensor

Green - Lock Out (-)500mA

Blue - Unlock Out (-)500mA

Valet Switch

LED

Orange -       Starter Interrupt Output (-)500mA

Blue -          Hood/Trunk Trigger input (-)

Black/White - Dome light Activation Output(-)500mA

Brown/White- Horn Output (-)500mA

Gray -          Trunk release Output (-)500mA

Brown -        Siren Ouptut (+)3A

Green -         Door Trigger Input (-)

Purple -        Door Trigger Input (+)

White -          Parking Light Output (+)10A

Red -            +12V Battery 

Yellow -         +12V Ignition Input

Black  -         Chassis Ground Input (-)

Red

Blue

Control Unit

A10

Summary of Contents for A10 SERIES

Page 1: ...A10 SERIES VEHICLE SECURITY SYSTEM PRODUCT MANUAL...

Page 2: ...ear if required for repair and or replacement of any defective parts A copy of the original purchase and installation receipt must accompany any products returned for warranty service Warranty is limi...

Page 3: ...7 Ignition Controlled Door Locks Page 7 Dome Light Activation Page 7 Auxiliary Function Outputs Page 7 Anti Carjacking Protection Page 7 5 System Installation Page 8 Mounting the Control unit Page 9 M...

Page 4: ......

Page 5: ...quire additional parts and or labor see store for details Astra A10 Page 1 Remote Door Locking Two Stage Door Unlocking Starter Defeat Horn Honk Illuminated Entry Remote Car Start Power Trunk Hatch Re...

Page 6: ...ers into the system have all desired transmitters ready and follow the steps below Note Up to 4 transmitters can be programmed to operate the system To erase any previously stored transmitter codes be...

Page 7: ...and separate the top and bottom halves of the case While replacing the battery make sure that the positive and negative terminals are positioned correctly then carefully reassemble the transmitter cas...

Page 8: ...rm for 30 seconds In the event the alarm is triggered and remains triggered continuously by the same sensor or input during a single arming cycle that sensor or input will be automatically bypassed un...

Page 9: ...Automatic Rearming feature will also be enabled even if it was not already programmed Panic Mode In the event of an emergency the transmitter s Panic feature can be used to instantly trigger the alar...

Page 10: ...n 5 seconds press Button 3 on the transmitter The siren will chirp 3 times 5 Press the valet switch the number of times equal to the desired code from 1 15 6 Turn off the ignition then arm the system...

Page 11: ...Anti Carjacking Protection For a higher level of personal security the system is equipped with three programmable Anti Carjacking modes When any Anti Carjacking mode is triggered the parking lights wi...

Page 12: ...ll vehicle systems before and after the installation 6 Always use a Volt Ohm meter for testing vehicle circuits Never use a test light 7 Always look before drilling any holes or mounting self tapping...

Page 13: ...ren Choose a siren mounting location that is away from heat sources such as exhaust manifolds and where it cannot be easily accessed from underneath the vehicle Be sure to face the siren downward to p...

Page 14: ...t 7A The WHITE wire must connect to the circuit that shows 12V when only the parking lights are on For parking light circuits exceeding 7 amps a relay is required For vehicle s with independent left a...

Page 15: ...n 3 The siren will chirp 4 times indicating that the reset signal was received All System Programming parameters are now set to factory default settings The Valet Mode is off 3 Turn off ignition Progr...

Page 16: ...mming the system for double unlock pulse 8 Arming Chirps Selects between normal and silent operation 9 Extended Parking Lights When selected the parking lights will remain on for 30 seconds after disa...

Page 17: ...Polarity Vacuum Adding Actuators Follow the diagrams below for connecting basic door lock systems For Two Stage door lock systems separately unlocks driver and passenger doors see following pages Door...

Page 18: ...Lock Diagrams Two Stage Negative Trigger Two Stage Positive Trigger When connected as shown below disarming the system will unlock only the driver s door Pressing the Aux 1 button will unlock all door...

Page 19: ...Astra A10 Page 15 Two Stage Door Lock Diagrams cont d Two Stage Reverse Polarity Two Stage Adding Actuators Aux 1 gray wire Aux 1 gray wire...

Page 20: ...ence received including interference that may cause undesired operation Technical Information Impact Sensor Green Lock Out 500mA Blue Unlock Out 500mA Valet Switch LED Orange Starter Interrupt Output...