Service Center Models
Model TP-100-244 (Figure 7) allows service centers to, perform
diagnostics, read the truck fault log, and record service/certification
records.
Diagnostics:
The Diagnostic Button allows for testing of the Super T.I.M. module and
for viewing the error log captured from prior loading attempts.
• Pressing the T.I.M. test will begin a memory test of the Super
T.I.M. module. Each memory bank will be tested for read/write
cycles and a progress bar will be displayed on the screen.
The test cannot be aborted once started and it typically takes
20-30 seconds to complete. Results will be indicated on
screen.
• Pressing the “View Log” button will display an error log
captured during the most recent loading activity. If a
compartment probe was faulty, the probe number and fault will
be displayed.
Truck Fault Log:
The Super T.I.M. records the last 5 fault conditions associated with the
overfill prevention and static grounding safety systems. Pressing the
“View Log” button will display the last fault recorded with a date and
time stamp. Prior faults can also be viewed using the down and up
buttons to scroll through them.
Figure 7. Model TP-100-244 Service Center Reader/Programmer
Model Specific Functions
Truck to Terminal Safety Communications
Summary of Contents for TP-100-244