![Scully TP-100-244 User Manual Download Page 7](http://html.mh-extra.com/html/scully/tp-100-244/tp-100-244_user-manual_1220092007.webp)
Page 5.
Connecting to a T.I.M.
Connecting to a New (uninstalled) TIM can be accomplished using the
test cable (Scully Part#235 001 000). Simply connect the stripped ends
of the Super T.I.M. to the like colored alligator clips of the cable, and
plug the cable into the T.I.M. Cable connector (see Figure 5) of the
Super T.I.M. Programmer.
To connect to a truck mounted T.I.M., use the test plug and cable
assembly (Scully Part# 092 000 252). Before connecting the plug into
the socket on the truck, ensure the removeable locator pin is screwed,
finger tight, into the correct position on the plug. The pin can be
unscrewed and repositioned as needed (See Figure 6).
Reading the T.I.M.
Each Truck Identification Module contains a unique serial number which
can be read by the programmer. To read a T.I.M.:
1. Connect the cable adapter of the Super T.I.M. Programmer to
a T.I.M. module
2. Press the “Read T.I.M.” button
The T.I.M. ID will be displayed on the screen, along with the T.I.M. Type,
and Alternate T.I.M. ID, if available.
Figure 6. Test Plug Pin Configuration
2-Wire (Green) Socket
5-Wire (Blue) Socket
Figure 5. T.I.M. Test Cable
General Operation
Truck to Terminal Safety Communications
White Slot 2
Purple Slot 1
1 2
Summary of Contents for TP-100-244
Page 2: ......
Page 18: ...Page 16 Super T I M Reader Programmer User Manual Notes ...
Page 19: ......