Page 1: ...TRUCK IDENTIFICATION MODULE READER PROGRAMMER Model TP 100 USER MANUAL 601000009 Rev A December 2018 ...
Page 2: ......
Page 3: ...M Reading a T I M Adjusting Settings Model Specific Functions Service Center Recording service activity Diagnostics Builder Default files Builder Parameters Carrier Certificate Status Load History Capacity Alternate T I M ID Terminal View Certificate View Load History View Capacity Technical Specifications Approvals 2 3 4 5 7 7 8 10 12 14 ...
Page 4: ...olution is user adjustable for sunlight usability as well as indoor use The programmer is lightweight yet durable enough for the standard toolbox Battery power provides constant use over multiple shifts and the standard AA size allows convenient replacement when needed A typical Programmer includes a T I M Cable connector for either new or already installed Super T I M modules The programmer with ...
Page 5: ...e taken to orient the new batteries according to the imprinted alignment images in the compartment Use 4 standard Alkaline AA batteries 4 Slide the cover back on the enclosure 5 Record the serial number off of the back of the unit and replace the rubber sleeve by stretching it over the case Re attach the adapter cable If unit is not going to be used for an extended period remove the batteries to a...
Page 6: ...ster the programmer to your facility When using the stylus the keyboard is calibrated for best results when aiming for the lower right corner of each key The programmer is available in four models Each model provides functionality specific to the needs of the tank truck builder carrier terminal or service center Every model features the ability to read the Super T I M ID and adjust programmer sett...
Page 7: ... removeable locator pin is screwed finger tight into the correct position on the plug The pin can be unscrewed and repositioned as needed See Figure 6 Reading the T I M Each Truck Identification Module contains a unique serial number which can be read by the programmer To read a T I M 1 Connect the cable adapter of the Super T I M Programmer to a T I M module 2 Press the Read T I M button The T I ...
Page 8: ...rd to enter the new parameter value and then press the Enter key to save The WiFi network name and password are case sensitive 3 To exit the edit screen from the keyboard without making changes press the tab key above the Caps Lock key Pressing the WiFi Connect button will join the network using the password entered A successful connection will be indicated on the screen and the IP Address will be...
Page 9: ...ce started and it typically takes 20 30 seconds to complete Results will be indicated on screen Pressing the View Log button will display an error log captured during the most recent loading activity If a compartment probe was faulty the probe number and fault will be displayed Truck Fault Log The Super T I M records the last 5 fault conditions associated with the overfill prevention and static gr...
Page 10: ...yboard enter the new value and press Enter on the keyboard 4 To exit the edit screen from the keyboard without making changes press the tab key above the Caps Lock key Truck Builder Models Model TP100 245 Figure 8 allows tank truck builders to record safety information including compartment configurations overfill system components compartment capacities and maximum ratings These parameters can be...
Page 11: ...batteries are changed To upload this parameter values saved to the default file to a new Super T I M press the Save to T I M button to start the upload The upload status will be displayed at the bottom of the screen A complete upload typically takes about 30 seconds Builder Parameters In addition to the default file upload feature parameters can be individually recorded in the Super T I M as well ...
Page 12: ...er T I M To view this certificate information using the programmer press the Certificates button Using the down and up buttons scroll to view the certificate records Load History Each time a truck loads at the terminal the load safety details are saved to the Super T I M and can be viewed with the programmer These parameters include where the last load was obtained the date time of the last load w...
Page 13: ... updated recorded and press Edit 2 Using the on screen keyboard enter the new value and press Enter on the keyboard 3 To exit the edit screen from the keyboard without making changes press the tab key above the Caps Lock key Alternate T I M ID Terminals have the option of authorizing a load based on a fixed Trailer Identification Module number The Super T I M has additional reference information a...
Page 14: ...using the programmer press the Certificates button Using the down and up buttons scroll to view the certificate records Dates are saved in format MM DD YY Load History Each time a truck loads at the terminal the load safety details are saved to the Super T I M and can be viewed with the programmer These parameters include where the last load was obtained the date time of the last load what was loa...
Page 15: ... I M stores the capacity limits of each tank truck compart ment and communicates this to the terminal during loading for improved overfill prevention The capacity limits for each compartment can be viewed by pressing the Capacity button Use the down and up buttons to scroll through the parameters on the screen Pressing the Exit button returns to the main screen Model Specific Functions Truck to Te...
Page 16: ...an radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user i...
Page 17: ...nada s licence exempt RSSs Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applica bles aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions...
Page 18: ...Page 16 Super T I M Reader Programmer User Manual Notes ...
Page 19: ......
Page 20: ... are made in the U S A In addition we back up our products with the best service in the industry We have direct sales and service personnel in the U S A The United Kingdom and Europe and are represented in over 50 countries For more information and 24 hour technical assistance call Scully Signal Company at 1 800 2SCULLY 1 800 272 8559 Copyright 2018 Scully Signal Company Scully Signal Company 70 I...